Effect of Axial Magnetic Flux Compression on the Magnetic Rayleigh-Taylor Instability (Theory)
Abstract not provided
Engineering topics
Publications and source records attributed to McBride, R D.
Abstract not provided
No abstract prepared.
Current pulse shaping techniques, originally developed for planar dynamic material experiments on the Z-machine [M. K. Matzen et al., Phys. Plasmas 12, 055503 (2005)], are adapted to the design of controlled cylindrical liner implosions. By driving these targets with a current pulse shape that prevents shock formation inside the liner, shock heating is avoided along with the corresponding decrease in electrical conductivity ahead of the magnetic diffusion wave penetrating the liner. This results in an imploding liner with a significant amount of its mass in the solid phase and at multi-megabar pressures. Pressures in the solid region of a shaped pulse driven beryllium liner fielded on the Z-machine are inferred to 5.5 Mbar, while simulations suggest implosion velocities greater than 50kms{sup -1}. These solid liner experiments are diagnosed with multi-frame monochromatic x-ray backlighting which is used to infer the material density and pressure. This work has led to a new platform on the Z-machine that can be used to perform off-Hugoniot measurements at higher pressures than are accessible through magnetically driven planar geometries.
A recent publication [D. B. Sinars et al., Phys. Rev. Lett. 105, 185001 (2010)] describes the first controlled experiments measuring the growth of the magneto-Rayleigh-Taylor instability in fast ({approx}100 ns) Z-pinch plasmas formed from initially solid aluminum tubes (liners). Sinusoidal perturbations on the surface of these liners with wavelengths of 25-400 {mu}m were used to seed single-mode instabilities. The evolution of the outer liner surface was captured using multiframe 6.151 keV radiography. The initial paper shows that there is good agreement between the data and 2-D radiation magneto-hydrodynamic simulations down to 50 {mu}m wavelengths. This paper extends the previous one by providing more detailed radiography images, detailed target characterization data, a more accurate comparison to analytic models for the amplitude growth, the first data from a beryllium liner, and comparisons between the data and 3D simulations.
The first controlled experiments measuring the growth of the magneto-Rayleigh-Taylor instability in fast ({approx}100 ns) Z-pinch plasmas are reported. Sinusoidal perturbations on the surface of an initially solid Al tube (liner) with wavelengths of 25-400 {mu}m were used to seed the instability. Radiographs with 15 {mu}m resolution captured the evolution of the outer liner surface. Comparisons with numerical radiation magnetohydrodynamic simulations show remarkably good agreement down to 50 {mu}m wavelengths.
Raising the power of X-ray emission from an X-pinch by increasing the pinch current to the megampere level requires the corresponding increase in the initial linear mass of the load. This can be achieved by increasing either the number of wires or their diameter. In both cases, special measures should be undertaken to prevent the formation of a complicated configuration with an uncontrolled spatial structure in the region of wire crossing, because such a structure breaks the symmetry of the neck formed in the crossing region, destabilizes plasma formation, and degrades X-ray generation. To improve the symmetry of the wire crossing region, X-pinch configurations with a regular multilayer arrangement of wires in this region were proposed and implemented. The results of experiments with various symmetric X-pinch configurations on the COBRA facility at currents of {approx}1MA are presented. It is shown that an X-pinch with a symmetric crossing region consisting of several layers of wires made of different materials can be successfully used in megampere facilities. The most efficient combinations of wires in symmetric multilayer X-pinches are found in which only one hot spot forms and that are characterized by a high and stable soft X-ray yield.
Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.
The limited understanding of the mechanisms driving the mass ablation rate of cylindrical wires arrays is presently one of the major limitations in predicting array performance at the higher current levels required for inertial confinement fusion (ICF) ignition. Continued investigation of this phenomenon is crucial to realize the considerable potential for wire arrays to drive both ICF and inertial fusion energy, by enabling a predictive capability in computational modeling. We present the first study to directly compare the mass ablation rates of wire arrays as a function of the current rise rate. Formation of the precursor column is investigated on both the MAPGIE (1 MA, 250ns [Mitchell et al., Rev. Sci. Instrum. 67, 1533 (1996)]) and COBRA (1 MA, 100ns [Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]) generators, and results are used to infer the change in the effective ablation velocity induced by the rise rate of the drive current. Laser shadowography, gated extreme ultraviolet (XUV) imaging, and x-ray diodes are used to compare the dynamical behavior on the two generators, and X-pinch radiography and XUV spectroscopy provide density evolution and temperature measurements respectively. Results are compared to predictions from an analytical scaling model developed previously from MAGPIE data, based on a fixed ablation velocity. For COBRA the column formation time occurs at 116{+-}5 ns and for Al arrays and 146{+-}5 ns for W arrays, with Al column temperature in the range of 70-165 eV. These values lie close to model predictions, inferring only a small change in the ablation velocity is induced by the factor of 2.5 change in current rise time. Estimations suggest the effective ablation velocities for MAGPIE and COBRA experiments vary by a maximum of 30%.
A symmetric X pinch configuration that is conducive to using large numbers of wires on {>=}1 MA pulsed power generators has been tested at 1 MA. Using an initial configuration of wires before their twisting, similar to nested cylindrical wire arrays, enables a geometrically simple, compact, multilayer wire configuration at the X pinch crossing region. Multilayer X pinches with the same or different materials in the inner and outer wire layers were tested. Optimization resulted in X pinch radiation sources with peak power comparable to the most successful single layer X pinch, but with a compact, single bright X radiation source more reliably obtained using the nested configuration.
The presented research focuses on investigation of Z-pinch plasma formation, implosion, and radiation characteristics as a function of the load configuration. The single planar and multi-planar wire arrays as well as compact cylindrical wire arrays were studied on the 1.3 MA UNR Zebra and 1 MA Cornell COBRA generators. The largest yields and powers were found for W and Mo double planar and compact wire arrays. A possibility of radiation pulse shaping was demonstrated. Two types of bright spots were observed in plasmas. A comparison of Mo double planar and compact wire array data indicates the possibility that the same heating mechanism operates during the final implosion and stagnation stages.
Recent results of X pinch studies on the COBRA generator at Cornell University (peak current up to 1.2 MA and rise time of 100 ns) are presented. Using an initial configuration of wires before their twisting, similar to nested cylindrical wire arrays enables the assembly of a symmetric configuration at the X pinch crossing region. It also enables an investigation of multilayered X pinches. X pinches with different configurations, including with different materials in the inner and outer wire layers, were tested.
Recent experiments on the 500 kA XP pulsed-power generator at Cornell University have explored the properties of optical spectra in single wires and wire arrays. In the single wire experiments, {approx}1% of the current from XP has been directed through the single wire. Spectra have been recorded using a half-meter spectrometer and a CCD camera located adjacent to the XP pulser. We are studying the visible spectra emitted by the wires and the background light from the machine hardware in order to identify the levels of current per wire for which visible spectroscopy might provide a means to measure magnetic field strength. We have also investigated the dependence of single wire visible spectra on the current, which was measured using a calibrated non-integrating Rogowski coil. UV and XUV diodes were employed to gather information about the temporal structure of the background and wire radiation. The line radiation in the spectra was recorded with wire currents at the few kA level. This is comparable to the first 10 ns of a 32-wire array experiment on 1 Ma generator and a 600-wire array at 20 MA.
We present the first study to directly compare the mass ablation rates of cylindrical wire arrays as a function of the current rise-rate. Formation of the precursor column is investigated on both the MAPGIE (1 MA, 250 ns) and COBRA (1 MA, 100 ns) generators, and results are used to infer the change in the mass ablation rate induced by the rise-rate of the drive current. Laser shadowography, gated XUV imaging and x-ray diodes are used to compare the dynamical behavior both generators, and x-pinch radiography and XUV spectroscopy and provide density evolution and temperature measurements respectively. Results are compared to predictions from an analytical scaling model based on a fixed ablation rate, and the close correlation achieved suggests that the effective ablation velocity is not a strong function of the current rise rate.
The Cornell University COBRA pulser is a nominal 1 MA machine, capable of driving up to 32 wire cylindrical Z-pinch arrays. COBRA can operate with variable current risetimes ranging from 100 ns to 200 ns (short and long pulse, respectively). Wires are typically strung with a 'press' contact to the electrode hardware, where the wire is loosely pulled against the hardware and held there to establish electrical contact. The machine is normally negative, but a bolt-on convolute can be used to modify the current path and effectively produce positive polarity operation at the load.Previous research with single wires on a 1-5 kA pulser has shown that soldering the wire, thereby improving the wire/electrode contact, and operating in positive polarity can improve the energy deposition into the wire and enhance wire core expansion. Negative polarity showed no difference. Previous experiments on the negative polarity, 20 MA, 100 ns Z accelerator have shown that improving the contact improved the x-ray yield.Cornell data were collected on 16-wire Aluminum Z-pinch arrays in negative polarity. Experiments were conducted with both short and long current pulses with soldered and no-soldered wire/electrode contacts. The initiation, ablation, implosion and stagnation phases were compared for these four conditions. Time dependent x-ray signals were measured using diodes and diamond detectors. An inductive voltage monitor was used to infer minimum current radius achieved, as defined by a uniform shell of current moving radially inward, producing a time dependent inductance. Total energy data were collected with a metal-strip bolometer. Self-emission data were collected by an XUV 4-frame camera and an optical streak camera.In negative polarity and with short pulses, soldering appeared to produce a smaller radius pinch and decrease variations in the x-ray pulse shape. The bolometer, laser backlighter, 4-frame and streak cameras showed negligible differences in the initiation ablation and implosion phases. X-ray yield was increased with soldered arrays in negative polarity with long pulses. The bolometer also showed a 50% increase in radial power emitted for soldered arrays. 4-frame images showed soldered arrays have a more pronounced 'Christmas Tree' effect originating from the cathode. The inductive voltage monitor showed, with both long and short pulses, that soldered and no-solder arrays reached the same minimum current radius at the same time. However, with long pulses soldered arrays radiate x-rays at the time of minimum current radius while no-solder array x-ray output is delayed by {approx}20 ns, resulting in decreased x-ray yield.
We are investigating the development of the axial instability, a modulation of the size of the coronal plasma that develops around each wire in wire-array Z-pinches. The modulation is a result of nonuniform ablation of material from the relatively cold wire core. It has long been known that the wavelength of this modulation is constant late in time and, since it is unique to different materials, it has come to be known as the fundamental mode. In these experiments we imaged individual wires with laser shadowgraphy early in time primarily in low wire number, large wire diameter aluminum arrays for ease of viewing. We Observe the development of this modulation from the time of initiation of coronal plasma, obtaining its dominant wavelength and amplitude growth as a function of time. We also studied the instability on coiled wires, which modify the wire ablation mechanism and completely suppress the fundamental mode[Hall2008]. time is discussed.
Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.
Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.
The results of experiments with combined aluminum (Al) and stainless steel (SS) alloy 304, nested wire arrays from the 1 MA COBRA generator at Cornell University are presented. The loads studied consisted of a 6 mm diameter inner array and a 13 mm diameter outer array with a different material in each array: SS or aluminum. Al implodes before SS in all loads studied, even when Al was on the inner array. The new wire ablation dynamic model and spectroscopic modeling are used to interpret these data. The observed implosion dynamics are likely a result of the higher ablation rate of Al. These initial results suggest that combining wire materials with different ablation rates in wire array loads could be developed into a useful technique for x-ray pulse shaping and radiation yield optimization.