Development of a Portable Pixelated Fast-Neutron Imaging Panel
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to McConchie, Seth.
Explore the source record for details and available documents.
This document is the primary deliverable for a scoping study proposed to DOE National Laboratory Announcement Number LAB 19-2114 in the NNSA research area. The study supports user applications employing active neutron interrogation by providing a science plan to improve the modeling capability and the nuclear data that radiation transport codes use. Users rely on the accuracy of the elastic scattering and non-elastic cross-sections spanning thermal energies to 14 MeV (and higher in some cases) for modeling the neutron transport through complex geometries of materials potentially composed of many elements. While the elastic scattering cross-section data are accepted for all commonly occurring elements, the non-elastic cross-section data and the associated emission data include reaction channels that require attention. The study focused on the non-elastic reactions that emit secondary, also known as prompt, gammas with the premise that many users would benefit from improved modeling of these reactions. Many users develop material assay technologies based upon gamma signatures from radiative capture, inelastic scattering, and reactions on low-Z isotopes emitting multiple particles, so the nuclear data gaps, modeling deficiencies, and recommendations for addressing the shortfalls were assessed for these reactions. Fission gammas were excluded from this study because there are other efforts underway to address known shortfalls. Follow-on efforts that successfully execute the recommendations will tangibly improve to the ability to model gamma signatures and backgrounds for user applications, such as controlled substance detection, oil-well logging, and space exploration.
Abstract not provided.
Explore the source record for details and available documents.
Not Available
Not Available
A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a fast-neutron tomographic imaging system developed at Oak Ridge National Laboratory. The system uses an associated particle DT (deuterium-tritium) neutron generator as the source and 25 mm × 25 mm × 100 mm plastic scintillators as the neutron detectors. Two image quality indicators were examined: 1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder and 2) a variety of short steels pins embedded radially in the surface of a shielded polyethylene cylinder. Measurements demonstrated detectability down to approximately 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution and small feature detection limit. The current DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor in the current system configuration.
A comparison of the characteristics of the Nuclear Materials Identification System (NMIS) and its more fieldable version that was developed for future treaty applications, the Fieldable Nuclear Materials Identification System (FNMIS), is presented. Both systems were developed for the US Department of Energy (DOE) Office of Nuclear Verification (ONV). Under the Warhead Safety and Security Exchange Agreement, NMIS was also jointly developed with the Russian Federation. The configuration of the systems and their characteristics are described. In addition, the capabilities, advantages and disadvantages, and a comparison fast-neutron transmission imaging measurement is presented. The comparison measurements gave essentially the same results because the software and imaging apparatus have the same capabilities, with the FNMIS completing the measurements slightly faster. NMIS is an open system that is more easily modified for research applications and is not suitable for the ONV mission, and FNMIS is compatible with an information barrier, which is more useful for ONV applications.
The point kinetics model relies upon a series of assumptions that simplify the process of neutron fission chain propagation. Tagged neutron interrogation of uranium using 14.1 MeV neutrons can potentially benefit from the use of the point kinetics model, but the appropriateness of the model's assumptions have yet to be validated for this application. The two assumptions considered by this work are the assumption that a single distribution can be used to describe the neutron multiplicity of a chain-starting event and the assumption that parasitic neutron capture within uranium is negligible. Monte Carlo simulations are used to evaluate the appropriateness of each assumption, as well as the consequences on the emitted doubles rate. This work demonstrates that the use of the point kinetics model for this application is possible, but corrections to the source multiplicity assumption are necessary that would likely require prior knowledge of sample isotopics.
An extension of the point kinetics model is developed in this paper to describe the neutron multiplicity response of a bare uranium object under interrogation by an associated particle imaging deuterium-tritium (D-T) measurement system. This extended model is used to estimate the total neutron multiplication of the uranium. Both MCNPX-PoliMi simulations and data from active interrogation measurements of highly enriched and depleted uranium geometries are used to evaluate the potential of this method and to identify the sources of systematic error. The detection efficiency correction for measured coincidence response is identified as a large source of systematic error. If the detection process is not considered, results suggest that the method can estimate total multiplication to within 13% of the simulated value. Values for multiplicity constants in the point kinetics equations are sensitive to enrichment due to (n, xn) interactions by D-T neutrons and can introduce another significant source of systematic bias. This can theoretically be corrected if isotopic composition is known a priori. Finally, the spatial dependence of multiplication is also suspected of introducing further systematic bias for high multiplication uranium objects.
Abstract The 3rd Generation Attribute Measurement System project has been tasked by the U.S. National Nuclear Security Administration Office of Nuclear Verification to develop the next generation of attribute measurement system for potential verification applications. The primary improvements of this effort, compared to previous attribute measurement systems, are to address authentication and certification concerns throughout the design and development process and to conduct attribute measurements for highly enriched uranium and high explosives in addition to plutonium. This paper will present attribute measurement techniques under consideration by the project.
Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.
Pulsed neutron interrogation measurements have been performed on highly enriched uranium (HEU) oxide fuel pins and depleted uranium (DU) metal using a D-D neutron generator (2x10{sup 6} neutrons-s{sup -1}) and moderated {sup 3}He tubes at the Idaho National Laboratory Power Burst Facility. These measurements demonstrate the ability to distinguish HEU from DU by coincidence counting using a pulsed source. The amount of HEU measured was 8 kg in a sealed 55-gallon drum compared to 31 kg of DU. Neutron events were counted during and after the pulse with the Nuclear Materials Identification System (NMIS) and used to calculate the neutron coincidence time distributions. Passive measurements were also performed for comparison with the pulsed measurements. This paper presents the neutron coincidence time distribution and Feynman variance results from the measurements.