Search NASASearch

Engineering topics

McCubbin, Francis M.

Publications and source records attributed to McCubbin, Francis M..

At least 19 records

Adapting Apollo-Era Instrumentation for Cold Sample Processing While Maintaining Curatorial Standard Practices

The goal of the Apollo Next Generation Sample Analysis (ANGSA) Program is to study “specially curated samples,” that is, unstudied Apollo samples that have been preserved under unique conditions. A subset of the funded ANGSA work includes the study of Apollo samples stored under cold conditions since their return from the Moon. Ongoing ANGSA processing and future returned samples require cold curation strategies to preserve the integrity of organic and other temperature-sensitive constituents within those samples. Standard Apollo curation processing hardware and procedures are designed for room temperature operations, not cold conditions. This abstract details the major modifications of a heritage lunar cabinet in preparation for the first cold curation processing at Johnson Space Center. Future publications will provide greater detail on the low temperature materials and operation procedures. This work not only supports Apollo but also future cold sample return missions.

Amick, Cecilia L.

Using Simulated Micrometeoroid Impacts to Understand the Progressive Space Weathering of the Surface of Mercury

The surfaces of airless bodies such as Mercury are continually modified by space weathering, which is driven by micrometeoroid impacts and solar wind irradiation. Space weathering alters the chemical composition, microstructure, and spectral properties of surface regolith. In lunar and ordinarychondritic style space weathering, these processes affect the reflectance properties by darkening (lowering of reflectance), reddening (increasing reflectance with increasing wavelength), and attenuation of characteristic absorption features. These optical changes are driven by the production of nanophase Febearing particles (npFe). While our understanding of these alteration processes has largely been based on data from the Moon and near-Earth S-type asteroids, the space weathering environment at Mercury is much more extreme. The surface of Mercury experiences a more intense solar wind flux and higher velocity micrometeoroid impacts than its planetary counterparts at 1 AU. Additionally, the composition of Mercury’s surface varies significantly from that of the Moon. Most notably, a very low albedo unit has been identified on Mercury’s surface, known as the low reflectance material (LRM). This unit is enriched with up to 4 wt.% carbon, likely in the form of graphite, over the local mean. In addition, the surface concentration of Fe across Mercury’s surface is low (<2 wt.%) compared to the Moon. Our understanding of how these low-Fe and carbon phases are altered as a result of space weathering processes is limited. Since Fe plays a critical role in the development of space weathering features on other airless surfaces (e.g., npFe), its limited availability on Mercury may strongly affect the space weathering features in surface materials. In order to understand how space weathering affects the chemical, microstructural, and optical properties of the surface of Mercury, we can simulate these processes in the laboratory [7]. Here we used pulsed laser irradiation to simulate the short duration, high temperature events associated with micrometeoroid impacts. We used forsteritic olivine, likely present on the Mercurian surface, with varying FeO contents, each mixed with graphite, in our experiments. We then performed reflectance spectroscopy and electron microscopy to investigate the spectral, chemical, and microstructural changes in these samples.

Thompson, Michelle S.

Revolutionizing our Understanding of the Solar System via Sample Return from Mercury

Data from Mariner 10, MESSENGER, and ground-based telescopic observations have facilitated great advancements towards understanding the geochemistry, geology, internal structure, exosphere, and magnetosphere of Mercury. However, there are critical science questions that can be only addressed via examination of a sample in Earth-based laboratories, where numerous highly sensitive analytical measurements are possible. Collecting a sample from the surface of Mercury and bringing it to Earth for in-depth analysis would allow for transformative Solar System science to be conducted, examining aspects of our Solar System such as the evolution of the protoplanetary disk, space weathering on airless bodies, the geochemical behavior of elements at extreme conditions, and the origin and distribution of volatiles across the terrestrial planets. Furthermore, our knowledge of Mercury’s differentiation and geochemical processes, chronology and geologic evolution, tectonism and geomechanical properties, and past and ongoing magnetism would be greatly advanced via analysis of a sample from Mercury. Although there are ample challenges and knowledge gaps associated with sample return from Mercury in terms of both spacecraft requirements and material requirements for curatorial facilities, a sample from the planet would be an invaluable scientific resource for generations to come, enabling the most sophisticated measurements to be brought to bear for decades and helping to truly unlock the mysteries of our Solar System.

Vander Kaaden, Kathleen E.

Meca500 Robotic Arm Developments Towards Astromaterials Curation Applications

As a part of the ongoing efforts to develop new curation tools and techniques for astromaterials within the Astromaterials Acquisition and Curation office at NASA’s Johnson Space Center, we are developing a variety of manually and electrically controlled micromanipulation systems. Most current techniques require manual manipulation, and in some cases the manipulation task is being done entirely freehand. The motorized systems avail-able are restricted to three degrees of freedom and use proprietary control systems. For example, the MicroSupport AxisPro manipulation system currently used in microscale particle experiments is limited in its range of motion, as it can only move the manipulators in a three axis Cartesian range over a predetermined area above microscope slides. While having an efficient user interface, the control system is proprietary and prevents custom development and optimization to extend the viable applications of the system. In order to address some of these limitations, we have been testing robotic designs with multiple degrees of freedom and of a variety of designs. We are currently investigating the Meca500 robotic arm by Mecademic as a potential manipulation system to overcome some of these obstacles.

Cowden, T. R.

Development of Low-Cost Micromanipulation Systems for Small Extraterrestrial Samples

The analysis of microscale to mm-scale astromaterials often involves the transfer of samples from storage or collection substrates to analytical substrates. These transfers are accomplished by hand (via tweezers or fine-tipped needles) or by utilizing micromanipulation instruments. Freehand manipulation of small particles is extremely challenging due to involuntary hand tremors on the order of 100μm and due to the triboelectric charging induced by frequent contact between the manipulation tool and the support substrate. Months or years of practice may be required before an investigator develops the necessary experience to confidently transfer a 10-20μm particle in this manner. Handling even mm-sized particles with fine-tipped tweezers can be challenging, due to the inability to precisely control the force with which grains are being held. Mechanical, hydraulic, and motorized/electrical micromanipulators enable the precise handling of microscale samples and are often utilized in laboratories where frequent small sample preparation is required. However, the price of such instruments (~ $10,000 to $100,000) makes them cost-prohibitive for some institutions. Graduate students or early-career scientists interested in conducting research on interplanetary dust particles, Itokawa particles returned by Hayabusa, or future samples returned by OSIRIS-REx or Hayabusa2 may experience difficulty in justifying the expense of a micromanipulator to their advisors or principle investigators. Johnson Space Center’s Astromaterials Acquisition and Curation Office and the Lunar and Planetary Institute conduct annual training for early career scientists and for investigators that require experience with handling of small extraterrestrial samples. In support of this training, we have been developing low-cost mechanical alternatives to expensive micromanipulators that training participants can implement in their respective facilities.

Snead, Christopher J.

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.

The Acquisition, Containment, and Curation of Mars Samples on Earth

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (henceforth AACO) is responsible for receiving and curating all of NASA’s extraterrestrial samples, current and future (as per NASA Policy Directive (NPD) 7100.10E “Curation of Extraterrestrial Materials”). As such, the AACO coordinates sample capture, containment, and transportation to the curation facility as well as documents, preserves, prepares, and distributes all of the samples within NASA’s astromaterial collections for research, education, and public outreach. Since the lunar rock and soil samples returned during the Apollo Program, NASA’s first Class V Restricted Earth Return Missions, the AACO curates six other astromaterials collections. Lessons learned from each collection and respective missions (e.g. Apollo, Genesis, Stardust) as well as advancements in science and technology have informed the AACO’s plan for acquiring and curating Martian samples. Given the nature of the collection, a mobile and modular facility is recommended. The two broad requirements a Mars sample facility must maintain are: 1) the ability to contain the samples to protect the public from exposure of an “unknown unknown” biological agent and 2) ensure the scientific integrity of the samples are maintained (while maximizing scientific outcome). Although Apollo samples were eventually deemed safe and released to the scientific community for evaluation, there is no guarantee that this will be the case for Martian samples. Therefore, the facility in which the samples will be contained and investigated must be modular and able to accommodate an array of instrumentation that could be highly variable depending on the initial scientific outcomes. Furthermore, in order to facilitate proper sample capture and containment upon landing as well as sample distribution to other laboratories with proper containment, a mobile facility is a valuable investment.

Harrington, Andrea D.

Isolation and Monitoring of Cleanroom-Associated Microbial Contaminates From Geological Collections

Microbial contamination is of particular interest to geological curation as many microorganisms can change mineral composition and produce compounds used as biosignatures used for the detection of life. Microbial cells can change the mineral composition of rocks through organic acid production and direct enzymatic oxidation/reduction of transition metals. Enzymatic oxidation of iron and manganese can occur at a rate several orders of magnitude faster than under abiotic conditions and produce highly reactive nanoparticle- sized oxides that can react and sorb other metals and organic compounds. Many fungi can also produce organic acids that dissolve and chelate mineral matrices chemically reducing and dissolving rock surfaces. Finally, several common soil-associated bacteria and fungi produce secondary metabolites that contain unusual amino acid analogs and non-ribosomal peptides containing both L- and D- chirality used in characterizing carbonaceous chondrites and the detection of extraterrestrial life.

Davis, Richard E.

The Geochemistry of Aubrites: Investigating Reduced Parent Bodies

The aubrites (~30 known meteorites) are a unique group of differentiated meteorites that formed on asteroids with oxygen fugacities (ƒO2) from ~2 to ~6 log units below the iron-wüstite buffer [1–2]. At these highly reduced conditions, elements deviate from the geochemical behavior exhibited at terrestrial ƒO2, forming FeO-poor silicates, Si-bearing metals, and exotic sulfides [3]. Here we examine the 3D mineralogy and the geochemistry of fourteen aubrites, including mineral major element compositions, bulk-rock compositions, and oxygen isotopic compositions to understand their formation and evolution at extreme ƒO2 conditions. While previous studies have described the petrology and 2D modal abundances of aubrites, this work investigates the 3D modal mineralogies of silicate, metal, and sulfide phases in aubrite samples, which are then com-pared to the available 2D data. We utilize X-ray computed tomography (XCT) to non-destructively analyze the distribution and abundances of mineral phases in aubrites and locate composite clasts of sulfide grains for future analysis.

Wilbur, Z. E.

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.

Discreditation of Bobdownsite and the Establishment of Criteria for the Identification of Minerals with Essential Monofluorophosphate (PO3F2-)

Bobdownsite, IMA number 2008-037, was approved as a new mineral by the Commission on New Minerals, Nomenclature and Classification (CNMNC) as the fluorine endmember of the mineral whitlockite. The type locality of bobdownsite is in Big Fish River, Yukon Canada, and bobdownsite was reported to be the first naturally occurring mineral with essential monofluorophosphate (PO3F2-). The type specimen of bobdownsite has been reinvestigated by electron probe microanalysis (EPMA), and our data indicate that fluorine abundances are below detection in the mineral. In addition, we conducted detailed analysis of bobdownsite from the type locality by gas chromatography isotope ratio mass spectrometry, Raman spectroscopy, EPMA, and NMR spectroscopy. These data were compared with previously published data on synthetic monofluorophosphate salts. Collectively, these data indicate that bobdownsite is indistinguishable from whitlockite with a composition along the whitlockite-merrillite solid solution. Bobdownsite is therefore discredited as a valid mineral species. An additional mineral, krásnoite, has been purported to have monofluorophosphate components in its structure, but reexamination of those data indicate that F- in krásnoite forms bonds with Al, similar to OH- bonded to Al in perhamite. Consequently, krásnoite also lacks monofluorophosphate groups, and there are currently no valid mineral species with monofluorophosphate in their structure. We recommend that any future reports of new minerals that contain essential monofluorophosphate anions be vetted by abundance measurements of fluorine, vibrational spectroscopy (both Raman and FTIR), and where paramagnetic components are permissibly low, NMR spectroscopy. Furthermore, we emphasize the importance of using synthetic compounds containing monofluorophosphate anions as a point of comparison in the identification of minerals with essential monofluorophosphate. Structural data that yield satisfactory P-F bond lengths determined by X-ray crystallography, coupled with direct chemical analyses of fluorine in a material do not constitute sufficient evidence alone to identify a new mineral with essential monofluorophosphate anions.

McCubbin, Francis M.

Applying Modern Analytical Techniques to the Apollo Samples: A Potential Model for Future Sample Return Missions

From 1969-1972 the Apollo missions collected 382 kg of lunar samples from six distinct locations on the Moon. Studies of the Apollo sample suite have shaped our understanding of the formation and early evolution of the Earth-Moon system, and have had important implications for studies of the other terrestrial planets (e.g., through the calibration of the crater counting record). Despite nearly 50 years of research on Apollo samples, scientists are still developing new theories about the origin and evolution of the Moon. In order to resolve these questions, scientists need access to new lunar samples, particularly new plutonic samples. Although no new large plutonic samples (i.e., hand-samples) remain to be discovered in the Apollo sample collection, there are many large polymict breccias in the Apollo collection containing relatively large (1 cm or larger) previously identified plutonic clasts, as well as a large number of unclassified lithic clasts. In addition, new, previously unidentified plutonic clasts are potentially discoverable within these breccias. The question becomes how to non-destructively locate and identify new lithic clasts of interest while minimizing the contamination and physical degradation of the samples.

Zeigler, Ryan A.

Curating Nasa's Future Extraterrestrial Sample Collections: the Role of Advanced Curation

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC) (henceforth referred to herein as NASA Curation Office) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F "Curation of Extraterrestrial Materials," JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.

McCubbin, Francis M.

The Role of Carbon in Exotic Crust Formation on Mercury

The terrestrial planets that comprise our inner Solar System, including the Moon, are all rocky bodies that have differentiated into a crust, mantle, and core. Furthermore, all of these bodies have undergone various igneous processes since their time of primary crust formation. These processes have resurfaced each of these bodies, at least in part, resulting in the production of a secondary crust, to which Mercury is no exception. From its first flyby encounter with Mercury on January 14, 2008, the MErcury Surface, Space ENvironment, GEochemistry and Ranging (MESSENGER) spacecraft collected data on the structure, chemical makeup, and density of the planet among other important characteristics. The X-Ray Spectrometer on board MESSENGER measured elevated abundances of sulfur and low abundances of iron, suggesting the planets oxygen fugacity (fO2) is several log10 units below the Iron-Wustite buffer. Similar to the role of other volatiles (e.g. sulfur) on highly reducing planetary bodies, carbon is expected to behave differently in an oxygen starved environment than it does in an oxygen enriched environment (e.g., Earth).

Vander Kaaden, Kathleen E.

Planning Related to the Curation and Processing of Returned Martian Samples

The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA’s extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E “Curation of Extraterrestrial Materials”, JSC is charged with “the curation of all extraterrestrial material under NASA control, including future NASA missions.” The Directive goes on to define Curation as including “…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach.” Here we describe some of the ongoing planning efforts in curation as they pertain to the return of martian samples in a future, as of yet unplanned, mission.

McCubbin, Francis M.

Endogenous Lunar Volatiles

Despite all of the new data generated on endogenous lunar volatiles since the publication of New Views of the Moon, many important questions remain unanswered or only partially resolved. This abstract looks to the future and discusses several of those important remaining questions on the topic of endogenous lunar volatiles.

McCubbin, Francis M.

Assessing the Behavior of Typically Lithophile Elements Under Highly Reducing Conditions Relevant to the Planet Mercury

With the data returned from the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (lvtESSENGER) mission, there are now numerous constraints on the physical and chemical properties of Mercury, including its surface composition. The high S and low FeO contents observed from MESSENGER suggest a low oxygen fugacity of the present materials on the planet's surface. Most of our understanding of elemental partitioning behavior comes from observations made on terrestrial rocks, but Mercury's oxygen fugacity is far outside the conditions of those samples, estimated at approximately 3-7 log units below the Iron-Wustite (lW) oxygen buffer, several orders of magnitude more reducing than other terrestrial bodies we have data from. With limited oxygen available, lithophile elements may instead exhibit chalcophile, halophile, or siderophile behaviors. Furthermore, very few natural samples of rocks that formed under reducing conditions (e.g., enstatite chondrites, achondrites, aubrites) are available in our collections for examination of this change in geochemical affinity. Our goal is to determine the elemental partitioning behavior of typically lithophile elements at lower oxygen fugacity as a function of temperature and pressure. Experiments were conducted at I GPa in a 13 mm QUICKpress piston cylinder and at 4 GPa in an 880-ton multi-anvil press, at temperatures up to 1850 C. The composition of starting materials for the experiments were designed so the final run products contained metal, silicate melt, and sulfide melt phases. Oxygen fugacity was controlled in the experiments by adding silicon metal to the samples, in order to utilize the Si-Si02 buffer, which is approx. 5 log units more reducing than the IW buffer at our temperatures of interest. The target silicate melt composition was diopside (CaMgSi206) because measured surface compositions indicate partial melting of a pyroxene-rich mantle. The results of our experiments will aid in our understanding of the fate of elements during the differentiation and thermal evolution of Mercury and other highly reducing planetary bodies.

Rowland, Rick, II