Search NASA⌕ Search

Engineering topics

McDowell, Jonathan

Publications and source records attributed to McDowell, Jonathan.

Disentangling the AGN and Star formation Contributions to the Radio–X-Ray Emission of Radio-loud Quasars at 1 < Z < 2

We constrain the emission mechanisms responsible for the prodigious electromagnetic output generated by active galactic nuclei (AGNs) and their host galaxies with a novel state-of-the-art AGN radio-to-X-ray spectral energy distribution model fitting code (ARXSED). ARXSED combines multiple components to fit the spectral energy distributions (SEDs) of AGNs and their host galaxies. Emission components include radio structures such as lobes and jets, infrared emission from the AGN torus, visible-to-X-ray emission from the accretion disk, and radio-to-ultraviolet emission from the host galaxy. Applying ARXSED to the radio SEDs of 20 3CRR quasars at 1 < z < 2 verifies the need for more than a simple power law when compact radio structures are present. The nonthermal emission contributes 91%–57% of the observed-frame 1.25 mm to 850 μm flux, and this component must be accounted for when using these wavelengths to estimate star formation properties. We predict the presence of strong radio-linked X-ray emission in more than half the sample sources. ARXSED estimates median (and the associated first and third quartile ranges) BH mass of ${2.9}_{1.7}^{6.0}\times {10}^{9}\,{M}_{\odot }$ , logarithm of Eddington ratio of $-{1.0}_{-1.2}^{-0.6}$ , and spin of ${0.98}_{0.94}^{0.99}$ for our sample. The inferred AGN torus and accretion disk parameters agree with those estimated from spectroscopic analyses of similar samples in the literature. We present the median intrinsic SED of the luminous radio-loud quasars at 1 < z ≲ 2; this SED represents a significant improvement in the way each component is modeled.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the ROSAT HRI Spectral Response

The ROSAT High Resolution Imager has a limited (2-band) spectral response. This spectral capability can give X-ray hardness ratios on spatial scales of 5 arcseconds. The spectral response of the center of the detector was calibrated before the launch of ROSAT, but the gain decreases with time and also is a function of position on the detector. To complicate matters further, the satellite is 'wobbled', possibly moving a source across several spatial gain states. These difficulties have prevented the spectral response of the ROSAT High Resolution Imager (HRI) from being used for scientific measurements. We have used Bright Earth data and in-flight calibration sources to map the spatial and temporal gain changes, and written software which will allow ROSAT users to generate a calibrated XSPEC (an x ray spectral fitting package) response matrix and hence determine a calibrated hardness ratio. In this report, we describe the calibration procedure and show how to obtain a response matrix. In Section 2 we give an overview of the calibration procedure, in Section 3 we give a summary of HRI spatial and temporal gain variations. Section 4 describes the routines used to determine the gain distribution of a source. In Sections 5 and 6, we describe in detail how, the Bright Earth database and calibration sources are used to derive a corrected response matrix for a given observation. Finally, Section 7 describes how to use the software.

Prestwich, Andrea H.↗

AXAF Coordinate Transformation at XRCF

Coordinate transformation between focal plane and detector pixel systems must be handled carefully at the X-ray Calibration Facility (XRCF) as it will be during flight. The High Resolution Mirror Assembly (HRMA) X-ray Detection System (HXDS) stage dithers, and the five-axis mount (FAM) attachment points underwent various types of motion during testing. At the XRCF when the FAM moved, the Science Instrument Module (SIM) travel direction was not necessarily aligned with the mirror axis motion, and, in addition, an arbitrary position offset had to be calibrated. Misalignment from the mirror axis was assessed by measuring its displacement from the boresight configuration of the default FAM frame, and the HXDS stage was monitored for motion from the default FAM reference point. Mirror position, prescribed in a mirror modal coordinate system, was measured in HRMA pitch and yaw axes. Prior to corrections for dithering and FAM movement, the coordinate data at XRCF also had to be corrected for possible misalignments of the mirror mount relative to XRCF and the default FAM axes due to the movement of the FAM feet. Those misalignments were processed in terms of yaw-pitch-roll Euler angles in the mirror nodal coordinate, and in the default FAM frame, respectively. An AXAF Science Center (ASC) coordinate library, pixlib, has been built to support these coordinate transformations and was used during x-ray calibration at the George C. Marshall Space Flight Center, Huntsville, AL. The design and implementation of this library will be discussed.

He, Helen↗