Applications of Laser Induced Breakdown Spectroscopy (LIBS) in Elemental Analysis of Varied Materials
Presented by NETL at Optics, Photonics & Laser Technologies Conference, 06/19
Engineering topics
Publications and source records attributed to McIntyre, Dustin.
Presented by NETL at Optics, Photonics & Laser Technologies Conference, 06/19
Poster Presented by NETL at URTeC Conference, 07/19
Presented by NETL at URTeC Workshop, 04/19
Presented by NETL at APS March Meeting 2019, 03/19
A Laser Induced Breakdown Spectroscopy (LIBS) probe using a dove prism for the laser media. The use of a dove prism allows for the removal of two mirrors over prior art schemes. The use of the dove prism allows for the light from the spark to be analyzed from the return path.
Laser induced breakdown spectroscopy (LIBS) has been used for the analysis of hydrocarbon bearing shale samples. Shale samples taken from a Marcellus gas well at depths ranging from 7498 to 7551 ft (2285.4–2301.5 m) were analyzed by LIBS using an 81 × 81 grid pattern covering an 8 × 8 mm area. The data collected from these experiments were used to construct 2D elemental maps for each sample including the hydrocarbon forming elements C and H. Results show that the spatial elemental composition of the shale varies due to the matrix of the rock, and as a function of the sample depth. The accuracy of the analysis was confirmed by analyzing a shale sample of known elemental concentrations and obtaining a good agreement between analyzed and reference values. It has been shown that LIBS can be used to determine elemental composition variations in hydrocarbon bearing shales in a laboratory setting. In conclusion, extending this capability into wellbores will enable producers to rapidly target resources with greater accuracy.
Presented by NETL at the 43rd International Technical Conference on Clean Energy, 6/18
We present the use of under water laser induced breakdown spectroscopy (LIBS) to detect two rare earth elements; Eu and Yb dissolved in bulk aqueous solutions at ambient and high-pressure conditions. Strong emission lines of Eu and Yb were identified in the underwater LIBS spectra. Temporal evolution of plasma, the effect of laser pulse energy, and the effect of pressure on the spectral emission were studied. Calibration curves were developed to demonstrate the possibility of using LIBS technique for their quantification and limits of detection were estimated.
Kinetic analysis of removal of three rare earth elements metals, Ce 3+ , Sm 3+ , and Yb 3+ ions from aqueous solutions in a continuous flow fixed bed reactor using Dowex 50W-X8 ion-exchange resin was conducted here. The performance of the fixed bed sorption was evaluated using the concept of the sorption breakthrough process. Parameters characteristic of a fixed bed sorption such as breakthrough times, saturation times, critical reactor lengths, and lengths of mass transfer zone were inferred from the metal ion concentration breakthrough curves. The sorption capacity of Dowex 50W-X8 ion-exchange resin for Ce 3+ , Sm 3+ , and Yb 3+ are 191, 252, and 294 mg/g, respectively. The sorption kinetics were evaluated using a zero-order, first-order and second-order reaction models. The kinetics of the sorption process follows a zero-order model which has not been reported before. The rate constants of sorption using the zero-order kinetic model are obtained. Two different analysis were conducted to identify whether the diffusion is intraparticle or film diffusion. Finally, both analysis confirms that the film diffusion is the controlling mechanism in reactor bed.
Explore the source record for details and available documents.
The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown site were used to characterize 9 different core sections of Upper Ordovician black shale from the Eastern Panhandle of West Virginia. The samples are representative of the upper Ordovician Martinsburg Formation, a Utica Shale equivalent, which is a carbonaceous black shale in the Appalachian Basin. The primary impetus of this work was to develop a standardized methodology for the rapid and detailed characterization of chemical composition, physical characteristics, and internal micro structure of lithologic samples with the NETL core characterization equipment. Having a standardized methodology combining these innovative techniques allows large, rapidly produced data sets to be available for multiple researchers and allows collaborative studies. The resultant data sets are presented as part of this report as well and can be accessed from NETL's Energy Data eXchange (EDX) online system (https://edx.netl.doe.gov) using the following link: https://edx.netl.doe.gov/dataset/martinsburg-formation-ct-data. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores with the additional information gathered through these tests. None of the equipment used was suitable for direct visualization of the shale pore space, though fractures and discontinuities were visible and detectable with all methods tested. High resolution CT imagery with the NETL industrial CT scanner was a powerful and insightful way to examine the details of fractures, discontinuities, minerals, and large crystals within the shale, but was time consuming both in image capture and analysis. As such, only a small percentage of the core was scanned at high resolution. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with the measurements from the multi-sensor core logger (including x-ray fluorescence, XRF, measurements) were very useful in identifying zones of interest for more detailed analysis and fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of all methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations of core that have traditionally been performed at NETL.
Interest in passively Q-switched microchip lasers as a means for miniaturization of laser-induced breakdown spectroscopy (LIBS) apparatus has rapidly grown in the last years. To explore the possibility of using a comparatively UV-Vis transparent absorber, we herein present the first report on the evaluation of a commercially available flash lamp-pumped passively Q-switched Nd:YAG laser with LiF:F 2 - saturable absorber as an excitation source in LIBS. Quantitative measurements of barium, strontium, rubidium and lithium in granite, rhyolite, basalt and syenite whole-rock glass samples were performed. Ablation craters produced on a rock glass sample were characterized using a computerized X-ray tomography. Using a gated intensified benchtop spectrometer, limits of detection of 0.97, 23, 37, and 144 ppm were obtained for Li, Sr, Rb, and Ba, respectively. Finally, we discuss the advantages of using such a laser unit for LIBS applications in terms of ablation efficiency, analytical performances, output energy, and standoff capabilities.
Laser induced breakdown spectroscopy (LIBS) is used for elemental characterization of outcrop samples from the Marcellus Shale. Powdered samples were pressed to form pellets and used for LIBS analysis. Partial least squares regression (PLS-R) and univariate calibration curves were used for quantification of analytes. The matrix effect is substantially reduced using the partial least squares calibration method. Predicted results with LIBS are compared to ICP-OES results for Si, Al, Ti, Mg, and Ca. As for C, its results are compared to those obtained by a carbon analyzer. Relative errors of the LIBS measurements are in the range of 1.7 to 12.6%. The limits of detection (LODs) obtained for Si, Al, Ti, Mg and Ca are 60.9, 33.0, 15.6, 4.2 and 0.03 ppm, respectively. An LOD of 0.4 wt.% was obtained for carbon. Finally, this study shows that the LIBS method can provide a rapid analysis of shale samples and can potentially benefit depleted gas shale carbon storage research.
The feasibility of using laser separation for rare earth recovery from coal ashes was explored. To do so, laser-induced motion and travel distances of some rare earth and rare earth oxides (Lu2O3, Yb2O3, HfO2, Dy2O3, Ta2O5, Tm, Lu, Ho, TeO2, La2O3, Ho, TiO2, Fe2O3 Y2O3, GeO2, Sc2O3) and mineral compounds (MgO, CaO, Al2O3, SiO2, KCl) that are commonly found is coal ashes were numerically investigated. The investigations were carried out for particles in quiescent air, (T = 300 K, μ = 18.46 x 10-6 N-s/m2 , ρ = 1.177 kg/m3 ) exposing to a CW laser beam of 6 mm in diameter and it was focused by a 500 mm focal length lens. The results showed that the separation distances between these elements varied from few micrometers to several millimeters and it became widened as the laser power increased. The important result presented here is that all rare earth oxides were separated and concentrated in a small area located near the beam waist while all other mineral compounds traveled further and concentrated in a small area far from the beam waist.
Presented at 2015 World of Coal Ash Conference (WOCA) (Nashville, TN)
To improve our understanding of the role of moisture and mineral matter with respect to CO 2 sequestration in unmineable coal semns, we investigated sorption and swelling behavior of several Eastern and Western US coal samples, pmiicularly, cuttings from San Juan Basin (Fruitland) site of the Southwest Regional Pminership and crushed-coal samples of the Central Appalachian Basin (Russell County, VA) coal seam received from the SECARB pminership. The CO 2 55°C sorption isotherm measurements have been completed for moist (as received) and dried samples representing the well probes. The results are summarized versus mineral matter and moisture content.
Combining CT imaging of geomaterials with computational fluid dynamics provides substantial benefits to researchers. With simulations, geometric parameters can be varied in systematic ways that are not possible in the lab. This paper details the conversion of micro-CT images of a physical fracture in Berea sandstone to several tractable finite volume meshes. By computationally varying the level of detail captured from the scans we produced several realistic fracture geometries with different degrees of wall-roughness and various geometric properties. Simulations were performed and it was noted that increasing roughness increased the resistance to fluid flow. Also, as the distance between walls was increased the mean aperture approached the effective aperture.