Search NASA⌕ Search

Engineering topics

McLaughlin, David A.

Publications and source records attributed to McLaughlin, David A..

Occupational Contamination with a Highly Enriched Uranium Solution

This medical case report describes the first reported instance of occupational skin contamination with a uranyl nitrate solution containing highly enriched uranium. The report provides an overview of the unique medical treatment and management considerations in such a case. Herein, internal dose assessment is covered in detail. The discussion covers key points regarding uranium characteristics, chemical and radiological damage to body tissues from HEU exposure, and resources available for assistance with a case of radiological contamination. This information adds to the limited medical literature on this topic and provides a valuable reference for medical personnel when dealing with this uncommon problem.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

WORKER INHALATION DOSE COEFFICIENTS FOR RADIONUCLIDES NOT PREVIOUSLY IDENTIFIED IN ICRP PUBLICATION 68

While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 methodology is used, along with updated radiological decay data and metabolic data, to identify committed equivalent dose coefficients [hT(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory’s Spallation Neutron Source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculation Package: Derivation of Facility-Specific Derived Air Concentration (DAC) Values in Support of Spallation Neutron Source Operations

Derived air concentration (DAC) values for 175 radionuclides* produced at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), but not listed in Appendix A of 10 CFR 835 (01/01/2009 version), are presented. The proposed DAC values, ranging between 1 E-07 μCi/mL and 2 E-03 {micro}Ci/mL, were calculated in accordance with the recommendations of the International Commission on Radiological Protection (ICRP), and are intended to support an exemption request seeking regulatory relief from the 10 CFR 835, Appendix A, requirement to apply restrictive DACs of 2E-13 μCi/mL and 4E-11 {micro}Ci/mL and for non-listed alpha and non-alpha-emitting radionuclides, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗