Search NASA⌕ Search

Engineering topics

McLaughlin, Stephanie

Publications and source records attributed to McLaughlin, Stephanie.

History and Status of ALSEP and the Apollo Lunar Data Project

A suite of automated scientific instruments (the Apollo Lunar Surface Experiment Package, or ALSEP) was installed at each of the landing sites of Apollo 12, 14, 15, 16, and 17 from 1969 to 1972. They operated from deployment until decommissioning on 30 September 1977. These data were continuously transmitted to Earth and saved on the Range Tapes, which were recorded at the Manned Space Flight Network stations. These data were also broken out by experiment and sent to the experiment Principal Investigators on what were called the P.I. Tapes. Starting in April 1973 the Range Tape data were stored in digital format on 7-track magnetic tapes, the ARCSAV Tapes. In February 1976, the handling of the Range Tapes was transferred to UT Galveston. They produced 9-track tapes referred to as the Work Tapes. Following the Apollo program the Range and ARCSAV tapes, which were never archived, were lost. The Work Tapes were archived at the National Space Science Data Center (NSSDC). Some investigators archived their individual experiment data with NSSDC as well, but much of the data had minimal documentation, were not in digital form, or were stored in difficult to translate formats. Data from many experiments were never delivered to the NSSDC. The Lunar Data Project was started to address the problem of both missing and not readily usable data. Our effort has resulted in recovery of some of the ARCSAV tapes, recovery and digitization of a large volume of Apollo scientific and technical documentation, and restoration of many ALSEP and other Apollo data collections. Restoration involves deciphering formats, assembling necessary ancillary data (metadata), and packaging data in digital format to be archived with the Planetary Data System (PDS). Recovery of the data from the ARCSAV tapes involved having the tapes read on special equipment and extracting the individual experiment data out of the integrated data stream. We will report on the history and status of the various recovery efforts.

Work Tapes↗

The Complex Spin State of 103P-Hartley 2: Kinematics and Orientation in Space

We derive the spin state of the nucleus of Comet 103P/Hartley 2, its orientation in space, and its short-term temporal evolution from a mixture of observations taken from the DIXI (Deep Impact Extended Investigation) spacecraft and radar observations. The nucleus is found to spin in an excited long-axis mode (LAM) with its rotational angular momentum per unit mass, M, and rotational energy per unit mass, E, slowly decreasing while the degree of excitation in the spin increases through perihelion passage. M is directed toward (RA, Dec; J2000) = 8+/-+/- 4 deg., 54 +/- 1 deg. (obliquity = 48 +/- 1 deg.). This direction is likely changing, but the change is probably <6 deg. on the sky over the approx. 81.6 days of the DIXI encounter. The magnitudes of M and E at closest approach (JD 2455505.0831866 2011-11-04 13:59:47.310) are 30.0 +/- 0.2 sq. m/s and (1.56 +/- 0.02) X 10(exp -3) sq. m /sq. s respectively. The period of rotation about the instantaneous spin vector, which points in the direction (RA, Dec; J2000) = 300 +/- 3.2deg., 67 +/- 1.3 deg. at the time of closest approach, was 14.1 +/- 0.3 h. The instantaneous spin vector circulates around M, inclined at an average angle of 33.2 +/- 1.3 deg. with an average period of 18.40 +/- 0.13 h at the time of closest approach. The period of roll around the principal axis of minimum inertia (''long'' axis) at that time is 26.72 +/- 0.06 h. The long axis is inclined to M by approx. 81.2 +/- 0.6 deg. on average, slowly decreasing through encounter. We infer that there is a periodic nodding motion of the long axis with half the roll period, i.e., 13.36+/- 0.03 h, with amplitude of 1 again decreasing through encounter. The periodic variability in the circulation and roll rates during a cycle was at the 2% and 10-14% level respectively. During the encounter there was a secular lengthening of the circulation period of the long axis by 1.3 +/- 0.2 min/d, in agreement with ground-based estimates, while the period of roll around the long axis changed by approx. -4.4 min/d at perihelion. M decreased at a rate of 0.038 (sq m/s) per day in a roughly linear fashion. Assuming a bulk density between 230-300 kg/m3 and a total volume for the nucleus of 8.09 X 10(exp 8) cubic m, the net torque acting on the nucleus was in the range 0.8-1.1 X 10(exp 5) kg m(exp 2) /s(exp 2). In order to bring the spacecraft photometric and imaging data into alignment on the direction of M, the directions of the intermediate and short principal axes of inertia had to be adjusted by 33 deg (on the sky) from the values indicated by the shape model with an assumed homogeneous interior. The adjusted direction of the intermediate axis is RA, Dec = 302 deg., -16.5 deg.. The morning and evening terminators in the images are identified, and the variation of the insolation at three regions on the nucleus associated with active areas calculated. The plume of water vapor observed in the inner coma is found to be directed close to the direction of local gravity over the sub-solar region for a range of reasonable bulk densities. The plume does not follow the projected normal to the surface at the sub-solar point.

Comets↗

Invited Article: Deep Impact instrument calibration

Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [{approx}1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of {approx}9 pixels. The charge coupled device (CCD) read noise is {approx}1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to {approx}1%. Spectrometer read noise is {approx}2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to {approx}10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of {approx}2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to {approx}0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗