Search NASA⌕ Search

Engineering topics

McMahon, William

Publications and source records attributed to McMahon, William.

PVcircuit [SWR-22-26]

The software contains objects that are building blocks for PV modeling and interactive data fitting based on: Optoelectronic models for tandem/multijunction solar cells including resistive and luminescent coupling; simulation of modules composed of 2T, 3T, and 4T tandem solar cells; and energy yield analysis of PV systems composed of tandem solar cells.

Geisz, John↗

PVcircuit v0.0.6 [SWR-22-26]

The software contains objects that are building blocks for PV modeling and interactive data fitting based on: Optoelectronic models for tandem/multijunction solar cells including resistive and luminescent coupling; simulation of modules composed of 2T, 3T, and 4T tandem solar cells; and energy yield analysis of PV systems composed of tandem solar cells.

Geisz, John↗

Voltage-Matched Strings using 3-Terminal Tandems: Fundamentals and End Losses

Strings constructed from 3-terminal tandem (3TT) cells can provide some of the performance benefits of voltage-matching with less cell complexity than strings based on 4-terminal tandem cells. However, the circuitry for a 3TT string can become more complex, making circuit analysis more challenging. Here we illustrate the essential features of single-polarity voltage-matched (VM) 3TT strings using representative examples. End losses are intrinsic to this type of string, but can be reduced by minimizing m and n in the Vtop/Vbot VM ratio m/n, and further mitigated by increasing the string length. This analysis agrees with preliminary experimental results.

3TT↗

High-Temperature Nucleation of GaP on V-Grooved Si

The use of nanopatterned {111}-faceted v-grooves has recently shown promise for growing high-quality III–V material on Si. Here, we study the effect of reactor conditions and surface pretreatments on the nucleation of GaP on v-grooved Si in a high-temperature regime, which offers the promise of a defect-free GaP/Si interface favorable for Si passivation and dislocation glide in the GaP. X-ray photoelectron spectroscopy was used to understand the Si surface chemistry prior to nucleation, and transmission electron microscopy was used to probe material quality of the nuclei. Temperature and V/III ratio were found to control the facet selectivity of nucleation. We demonstrate a condition of high temperature and high V–III ratio that leads to uniform nucleation at the bottom of the trenches, with initial material free of nucleation-related interfacial defects. This optimized condition was then shown to coalesce into a thin film after additional growth.

36 MATERIALS SCIENCE↗

Development of a Conditioned System-Level Groundwater Model to Evaluate Long-Term Groundwater Impacts within a Performance Assessment - 20115

A preliminary performance assessment (PA) of single-shell tank Waste Management Area (WMA) A-AX located at the U.S. Department of Energy (DOE)'s Hanford Site in southeastern Washington is being conducted to satisfy the requirements of DOE Order 435.1 [1] as it relates to closure of the single-shell radioactive waste tanks in the WMA A-AX tank farms. A PA assesses the fate, transport, and impacts of radionuclides within a low-level radioactive waste disposal facility in its assumed closure configuration and the subsequent potential doses to humans over a 1,000-year compliance period and a 10,000-year performance evaluation period. The WMA A-AX preliminary PA evaluation is structured around the complementary use of process-level and system-level models to calculate the facility performance against established DOE Order 435.1 [1] performance objectives. Process-level models are those that represent a detailed phenomenological representation of processes of concern in the PA. Process models typically only represent one or a few of the components of the PA, such as groundwater flow and transport, and must be integrated with other modeling elements to perform PA calculations. System-level models are those that are abstracted from the process models, retaining the essential features of the process model, while allowing integration of all aspects of the PA in a single modeling framework. System-level models are often characterized by coarser numerical discretization, lower dimensionality, or other similar simplifications compared to the process-level model. Traditionally, a three-dimensional (3-D) process-level model is utilized primarily to evaluate the long-term impact on groundwater and the potential doses to individuals who consume contaminated groundwater. System-level models are also utilized to evaluate the groundwater pathway in PAs. These models typically have reduced dimensionality (1-D) and are conditioned utilizing flow fields (Darcy fluxes) and moisture content distributions that are abstracted from the process level models. The abstraction approach assures that the flow field in both models is consistent for a specific set of input parameters for flow, differing only in the discretization and dimensionality of the two models. The preliminary WMA A-AX PA incorporates a detailed representation of the geological system and hydraulic properties within the 3-D model STOMP{sup C} numerical code so that the effects of relevant features and processes on water flow and radionuclide transport in the subsurface can be evaluated. The complementary system-level model is developed utilizing the GoldSim{sup C} code to implement a simplified, 1-D equivalent model to represent the groundwater pathway. Contaminant transport through the vadose zone and unconfined aquifer for Tc-99 and I-129 were evaluated in each of the models. Adjustments to the saturated portion of the GoldSim{sup C} 1-D model were required to mimic the dispersion effect captured with the 3-D STOMP{sup C} model. Once this conditioning was conducted, highly similar results for the transport of Tc-99 and I-129 were achieved at the point of calculation, located 100 m downgradient from the WMA A-AX fenceline. These radionuclides represent elements that are regarded as primary dose drivers in the PA groundwater pathway analysis. The high degree of conformance between the two models suggests that the use of the equivalent 1-D system model is suitable for evaluating the full suite of radionuclides that will be released from the tank sources within WMA A-AX over the 1,000-year compliance period and over the 10,000-year evaluation period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Past Leaks from Waste Management Area C, Hanford, Washington - 17525

Waste Management Area C (WMA C) at the Hanford Site was actively used for several decades for storing radioactive waste in tanks, and therefore is alternatively termed a 'waste management area,' or a 'tank farm.' During its operational life, a number of documented leaks occurred within or near to the WMA. The largest ones were associated with leaks in pipelines and diversion boxes, with the inlets or outlets of the tanks, or with leaks from the tanks themselves. Contaminants associated with these leaks were released to the soil, and mobile {sup 99}Tc has reached the groundwater exceeding drinking water standards. An analysis of the impact of past leaks on groundwater resources has been undertaken as part of the overall process of closing the tank farm. The analysis of leaks was carried out using a suite of scoping cases to evaluate alternative conceptual models for the leak behavior to identify those that are in reasonable agreement with observed concentrations of {sup 99}Tc in groundwater. Comparisons of the scoping cases with available {sup 99}Tc observations indicate the following. - Several of the scoping cases produced results that are inconsistent with observations, indicating that the assumptions in those cases may not be representative of conditions in WMA C. These negative results are valuable in improving the understanding of the migration of {sup 99}Tc from WMA C. - The remaining scoping analyses produced comparable results to each other, and none were obviously superior to others in terms of explaining the {sup 99}Tc observations. When uncertainties in groundwater fluxes were taken into account, these scoping analyses were capable of producing both arrival times and concentrations consistent with observed data for {sup 99}Tc. A representative model was used to implement a forward projection of a suite of contaminants of concern to show how the contamination associated with past leaks can be expected to evolve in the future. This paper presents these results and discusses their implications on groundwater contamination at WMA C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗