Search NASA⌕ Search

Engineering topics

McPeters, R.

Publications and source records attributed to McPeters, R..

Lidar Measurements of Stratospheric Ozone, Aerosols and Temperature during the SAUNA Campaign at Sodankyla, Finland

The Sodankyla Total Column Ozone Intercomparison (SAUNA) campaign took place at the Finnish Meteorological Institute Arctic Research Center (FMI-ARC) at Sodankyla, Finland (67.37 N) in two separate phases during early spring 2006, and winter 2007. These campaigns has several goals: to determine and improve the accuracy of total column ozone measurements during periods of low solar zenith angle and high total column ozone; to determine the effect of ozone profile shape on the total column retrieval; and to make validate satellite ozone measurements under these same conditions. The GSFC Stratospheric Ozone Lidar (STROZ), which makes profile measurements of ozone temperature, aerosols and water vapor participated in both phases of the campaign. During the deployments, more than 30 profile measurements were made by the lidar instrument, along with Dobson, Brewer, DOAS, ozonesonde, and satellite measurements. The presentation will concentrate on STROZ lidar results from the second phase of the campaign and comparisons with other instruments will be discussed. This will include both ground-based and satellite comparisons.

McGee, T.↗

The Antarctic Ozone Hole: Initial Results from Aura / OMI Compared with TOMS

A series of TOMS instruments (on November 7 , Meteor 3, and Earth Probe) has been monitoring the annual development of the Antarctic ozone hole since the 1980s. The ozone mapping instrument on Aura, OMI, is expected to take over this record of observation from the aging Earth Probe TOMS instrument. The area of the ozone hole can be taken as a sensitive indicator of the magnitude of ozone destruction each year. The timing of initial formation of the ozone hole and its duration are sensitive to the atmospheric dynamics of the southern polar regions. The entire TOMS data record (1978 - 2004) has recently been reprocessed with the new version 8 algorithm, which includes a revised calibration. The effect has been to slightly increase ozone hole area over earlier estimates, but only by 23%. OMI (ozone monitoring instrument) on Aura is a hyperspectral imaging instrument that operates in a pushbroom mode to measure solar backscattered radiation in the ultraviolet and visible. OMI has higher spatial resolution than TOMS - 14 x 24 km versus 38 km x 38 km from TOMS. OMI has now begin mapping total column ozone on a global basis in a measurement similar to TOMS. The ozone hole measurements for 2003 are compared with those from Earth Probe TOMS.

McPeters, R.↗

EOS-Aura's Ozone Monitoring Instrument (OMI): Validation Requirements

OMI is an advanced hyperspectral instrument that measures backscattered radiation in the UV and visible. It will be flown as part of the EOS Aura mission and provide data on atmospheric chemistry that is highly synergistic with other Aura instruments HIRDLS, MLS, and TES. OMI is designed to measure total ozone, aerosols, cloud information, and UV irradiances, continuing the TOMS series of global mapped products but with higher spatial resolution. In addition its hyperspectral capability enables measurements of trace gases such as SO2, NO2, HCHO, BrO, and OClO. A plan for validation of the various OM1 products is now being formulated. Validation of the total column and UVB products will rely heavily on existing networks of instruments, like NDSC. NASA and its European partners are planning aircraft missions for the validation of Aura instruments. New instruments and techniques (DOAS systems for example) will need to be developed, both ground and aircraft based. Lidar systems are needed for validation of the vertical distributions of ozone, aerosols, NO2 and possibly SO2. The validation emphasis will be on the retrieval of these products under polluted conditions. This is challenging because they often depend on the tropospheric profiles of the product in question, and because of large spatial variations in the troposphere. Most existing ground stations are located in, and equipped for, pristine environments. This is also true for almost all NDSC stations. OMI validation will need ground based sites in polluted environments and specially developed instruments, complementing the existing instrumentation.

Brinksma, E. J.↗

Uncertainties in Upper Stratospheric Ozone Trends from 1979 to 1996

The time series of differences in coincident measurements of ozone by Stratospheric Aerosol and Gas Experiment (SAGE) and by Solar Backscattered Ultraviolet (SBUV), SBUV/2, Umkehr and Microwave Limb Sounder (MLS) are analyzed, and the slopes in the differences are calculated. SAGE ozone measurements are also compared against those by HALOE. The purpose of these comparisons is to look for statistically significant nonzero slopes which could indicate long-term calibration problems in one or more of the measurement systems. It is found that the slopes are remarkably similar between the Northern and Southern Hemisphere midlatitudes, and, apart from a few exceptions, the slopes are also similar in the tropics. Slopes of MLS-SAGE differences and HALOE-SAGE trends from approximately 1992 to 1996 have values of approximately -0.5 +/- 0.4%/yr (95% confidence limits) in Umkehr layers 7-9 (which are centered at approx. 37, 42, and 47 km altitude). Umkehr-SAGE slopes for 1979-1996, however, are almost all positive and in the range -0.1 - 0.41%/yr for Umkehr layers 4 - 8, while SBUV-SAGE slopes for 1979-1989 are essentially zero in layers 4 - 7 and 0.3-0.4%/yr in layers 8 and 9. Averaging all these results with SBUV-SAGE 11 slopes from 1985 to 1989, the other sensors minus SAGE slopes are most likely between 0.2 and -0.2%/yr1 from approx. 20 to 40 km altitude. The results indicate slightly negative slopes in Umkehr layers 5-7 and positive slopes in the other three layers. There thus appears to be no overall drift in the SAGE ozone measurements from 1979 to 1996, but SAGE sunrise/sunset trend differences greater than 40 km altitude, combined with the more accurate SBUV-SAGE slopes for 1979-1989, suggest a most likely slope range of 0.4 to -0.4%/yr between 40 and 50 km altitude. SBUV/2 measurements from 1989 to 1994 have an upward trend with respect to SAGE measurements of approx. 0.7% /yr with some altitudinal structure; this slope exceeds the estimated 95% uncertainties on the SBUV/2 trends.

Cunnold, D. M.↗

Description and Sensitivity Analysis of the SOLSE/LORE-2 and SAGE III Limb Scattering Ozone Retrieval Algorithms

The SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) instruments are scheduled for reflight on Space Shuttle flight STS-107 in July 2002. In addition, the SAGE III (Stratospheric Aerosol and Gas Experiment) instrument will begin to make limb scattering measurements during Spring 2002. The optimal estimation technique is used to analyze visible and ultraviolet limb scattered radiances and produce a retrieved ozone profile. The algorithm used to analyze data from the initial flight of the SOLSE/LORE instruments (on Space Shuttle flight STS-87 in November 1997) forms the basis of the current algorithms, with expansion to take advantage of the increased multispectral information provided by SOLSE/LORE-2 and SAGE III. We also present detailed sensitivity analysis for these ozone retrieval algorithms. The primary source of ozone retrieval error is tangent height misregistration (i.e., instrument pointing error), which is relevant throughout the altitude range of interest, and can produce retrieval errors on the order of 10-20 percent due to a tangent height registration error of 0.5 km at the tangent point. Other significant sources of error are sensitivity to stratospheric aerosol and sensitivity to error in the a priori ozone estimate (given assumed instrument signal-to-noise = 200). These can produce errors up to 10 percent for the ozone retrieval at altitudes less than 20 km, but produce little error above that level.

Loughman, R.↗

Calibration of the Shuttle Ozone Limb Sounding Experiment (SOLSE) and the Limb Ozone Retrieval Experiment (LORE)

The calibration and characterization of two new instruments designed to retrieve ozone profiles into the lower stratosphere will be presented. These instruments will fly as a single payload on the Space Shuttle Columbia currently scheduled to lift off July 11, 2002. The purpose of SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) is to provide a thorough test of the limb ozone retrieval technique, which is being employed on several satellite instruments currently deployed or planned for deployment in the near future. OSIRIS (Optical Spectrograph and Infrared Imager System) and SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography) are already in orbit, while OMPS (the Ozone Mapping and Profiler Suite) is planned as the primary US ozone monitoring instrument in the next decade.. SOLSE is a Czerny-Turner spectrograph utilizing a 1k x 1k cooled CCD at the focal plane and covering the spectral range of 310-380 nm in the ultraviolet and 535-865 nm in the visible to near infrared. LORE is a 5 channel filter radiometer with center band wavelengths of 322, 350, 603, 675, and 1000 nm. The focus of this paper will be on measurements of the SOLSE spectrograph performance in the limb-viewing configuration including stray light rejection, spatial and spectral resolution and absolute radiometric response.

Janz, S. J.↗

Earth Probe Total Ozone Mapping Spectrometer (TOMS) Data Product User's Guide

Two data products from the Earth Probe Total Ozone Mapping Spectrometer (EP/TOMS) have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The EP/ TOMS began taking measurements on July 15, 1996. The instrument measures backscattered Earth radiance and incoming solar irradiance; their ratio is used in ozone retrievals. Changes in the reflectivity of the solar diffuser used for the irradiance measurement are monitored using a carousel of three diffusers, each exposed to the degrading effects of solar irradiation at different rates. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and the drift is less than 0.5 percent over the first year of data. The Level-2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level-3 product contains daily total ozone and reflectivity in a 1-degree latitude by 1.25 degrees longitude grid. Level-3 files containing estimates of LTVB at the Earth surface and tropospheric aerosol information are also available, Detailed descriptions of both HDF data-files and the CD-ROM product are provided.

McPeters, R.↗

ADEOS Total Ozone Mapping Spectrometer (TOMS) Data Products User's Guide

Two data products from the Total Ozone Mapping Spectrometer (ADEOS/TOMS) have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The ADEOS/ TOMS began taking measurements on September 11, 1996, and ended on June 29, 1997. The instrument measured backscattered Earth radiance and incoming solar irradiance; their ratio was used in ozone retrievals. Changes in the reflectivity of the solar diffuser used for the irradiance measurement were monitored using a carousel of three diffusers, each exposed to the degrading effects of solar irradiation at different rates. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and the drift is less than 0.5 percent over the 9-month data record. The Level 2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level 3 product contains daily total ozone and reflectivity in a 1-degree latitude by 1.25 degrees longitude grid. The Level 3 files containing estimates of UVB at the Earth surface and tropospheric aerosol information will also be available. Detailed descriptions of both HDF data files and the CDROM product are provided.

Krueger, A.↗