Search NASASearch

Engineering topics

McPeters, Richard

Publications and source records attributed to McPeters, Richard.

Trend Quality Ozone from NPP OMPS: The Version 2 Processing

A version 2 processing of data from two ozone monitoring instruments on Suomi NPP, the OMPS nadir ozone mapper and the OMPS nadir ozone profiler, has now been completed. The previously released data were useful for many purposes but were not suitable for use in ozone trend analysis. In this processing, instrument artifacts have been identified and corrected, an improved scattered light correction and wavelength registration have been applied, and soft calibration techniques were implemented to produce a calibration consistent with data from the series of SBUV/2 instruments. The result is a high-quality ozone time series suitable for trend analysis. Total column ozone data from the OMPS nadir mapper now agree with data from the SBUV/2 instrument on NOAA 19 with a zonal average bias of −0.2 % over the 60° S to 60° N latitude zone. Differences are somewhat larger between OMPS nadir profiler and N19 total column ozone, with an average difference of −1.1 % over the 60° S to 60° N latitude zone and a residual seasonal variation of about 2 % at latitudes higher than about 50°. For the profile retrieval, zonal average ozone in the upper stratosphere (between 2.5 and 4 hPa) agrees with that from NOAA 19 within ±3 % and an average bias of −1.1 %. In the lower stratosphere (between 25 and 40 hPa) agreement is within ±3 % with an average bias of +1.1 %. Tropospheric ozone produced by subtracting stratospheric ozone measured by the OMPS limb profiler from total column ozone measured by the nadir mapper is consistent with tropospheric ozone produced by subtracting stratospheric ozone from MLS from total ozone from the OMI instrument on Aura. The agreement of tropospheric ozone is within 10 % in most locations.

OMPS nadir ozone mapper

The Ozone Monitoring Instrument: Overview of 14 Years in Space

This overview paper highlights the successes of the Ozone Monitoring Instrument (OMI) on board the Aura satellite spanning a period of nearly 14 years. Data from OMI has been used in a wide range of applications and research resulting in many new findings. Due to its unprecedented spatial resolution, in combination with daily global coverage, OMI plays a unique role in measuring trace gases important for the ozone layer, air quality, and climate change. With the operational very fast delivery (VFD; direct readout) and near real-time (NRT) availability of the data, OMI also plays an important role in the development of operational services in the atmospheric chemistry domain.

KNMI

Synoptic Ozone, Cloud Reflectivity, and Erythemal Irradiance from Sunrise to Sunset for the Whole Earth as Viewed by the DSCOVR Spacecraft from the Earth-Sun Lagrange 1 Orbit

EPIC (Earth Polychromatic Imaging Camera) on board the DSCOVR (Deep Space Climate Observatory) spacecraft is the first earth science instrument located near the earth-sun gravitational plus centrifugal force balance point, Lagrange 1. EPIC measures earth-reflected radiances in 10 wavelength channels ranging from 317.5 to 779.5 nm. Of these channels, four are in the UV range 317.5, 325, 340, and 388 nm, which are used to retrieve O3, 388 nm scene reflectivity (LER: Lambert equivalent reflectivity), SO2, and aerosol properties. These new synoptic quantities are retrieved for the entire sunlit globe from sunrise to sunset multiple times per day as the earth rotates in EPIC's field of view. Retrieved ozone amounts agree with ground-based measurements and satellite data to within 3 %. The ozone amounts and LER are combined to derive the erythemal irradiance for the earth's entire sunlit surface at a nadir resolution of 1818 km2 using a computationally efficient approximation to a radiative transfer calculation of irradiance. The results show very high summertime values of the UV index (UVI) in the Andes and Himalayas (greater than 18), and high values of UVI near the Equator at equinox.

Cloud reflectivity

An Update on Ozone Profile Trends for the Period 2000 to 2016

Ozone profile trends over the period 2000 to 2016 from several merged satellite ozone data sets and from ground-based data measured by four techniques at stations of the Network for the Detection of Atmospheric Composition Change indicate significant ozone increases in the upper stratosphere, between 35 and 48 kilometers altitude (5 and 1 hectopascals). Near 2 hectopascals (42 kilometers), ozone has been increasing by about 1.5 percent per decade in the tropics (20 degrees S to 20 degrees N), and by 2 to 2.5 percent per decade in the 35 to 60 degree latitude bands of both hemispheres. At levels below 35 kilometers (5 hectopascals), 2000 to 2016 ozone trends are smaller and not statistically significant. The observed trend profiles are consistent with expectations from chemistry climate model simulations. This study confirms positive trends of upper stratospheric ozone already reported, e.g., in the WMO/UNEP (World Meteorological Organization/United Nations Environmental Programme) Ozone Assessment 2014 or by Harris et al. (2015). Compared to those studies, three to four additional years of observations, updated and improved data sets with reduced drift, and the fact that nearly all individual data sets indicate ozone increase in the upper stratosphere, all give enhanced confidence. Uncertainties have been reduced, for example for the trend near 2 hectopascals in the 35 to 60 degree latitude bands from about plus or minus 5 percent (2 sigma) in Harris et al. (2015) to less than plus or minus 2 percent (2 sigma). Nevertheless, a thorough analysis of possible drifts and differences between various data sources is still required, as is a detailed attribution of the observed increases to declining ozone-depleting substances and to stratospheric cooling. Ongoing quality observations from multiple independent platforms are key for verifying that recovery of the ozone layer continues as expected.

chemistry climate model simulations

A 40 Year Time Series of SBUV Observations: the Version 8.6 Processing

Under a NASA program to produce long term data records from instruments on multiple satellites (MEaSUREs), data from a series of eight SBUV and SBUV 12 instruments have been reprocessed to create a 40 year long ozone time series. Data from the Nimbus 4 BUV, Nimbus 7 SBUV, and SBUV/2 instruments on NOAA 9, 11, 14, 16, 17, and 18 were used covering the period 1970 to 1972 and 1979 to the present. In past analyses an ozone time series was created from these instruments by adjusting ozone itself, instrument by instrument, for consistency during overlap periods. In the version 8.6 processing adjustments were made to the radiance calibration of each instrument to maintain a consistent calibration over the entire time series. Data for all eight instruments were then reprocessed using the adjusted radiances. Reprocessing is necessary to produce an accurate latitude dependence. Other improvements incorporated in version 8.6 included the use of the ozone cross sections of Brion, Daumont, and Malicet, and the use of a cloud height climatology derived from Aura OMI measurements. The new cross sections have a more accurate temperature dependence than the cross sections previously used. The OMI-based cloud heights account for the penetration of UV into the upper layers of clouds. The consistency of the version 8.6 time series was evaluated by intra-instrument comparisons during overlap periods, comparisons with ground-based instruments, and comparisons with measurements made by instruments on other satellites such as SAGE II and UARS MLS. These comparisons show that for the instruments on NOAA 16, 17 and 18, the instrument calibrations were remarkably stable and consistent from instrument to instrument. The data record from the Nimbus 7 SBUV was also very stable, and SAGE and ground-based comparisons show that the' calibration was consistent with measurements made years laterby the NOAA 16 instrument. The calibrations of the SBUV/2 instruments on NOAA 9, 11, and 14 were more of a problem. The rapidly drifting orbits of these satellites resulted in relative time and altitude dependent differences that are significant. Despite these problems, total column ozone appears to be consistent to better than 1% over the entire time series, while the ozone vertical distribution is consistent to approximately 5%.

McPeters, Richard

The Re-Analysis of Ozone Profile Data from a 41-Year Series of SBUV Instruments

In this study we present the validation of ozone profiles from a number of Solar Back Scattered Ultra Violet (SBUV) and SBUV/2 instruments that were recently reprocessed using an updated (Version 8.6) algorithm. The SBUV dataset provides the longest available record of global ozone profiles, spanning a 41-year period from 1970 to 2011 (except a 5-year gap in the 1970s) and includes ozone profile records obtained from the Nimbus-4 BUV and Nimbus-7 SBUV instruments, and a series of SBUV(/2) instruments launched on NOAA operational satellites (NOAA 09, 11, 14, 16, 17, 18, 19). Although modifications in instrument design were made in the evolution from the BUV instrument to the modern SBUV(/2) model, the basic principles of the measurement technique and retrieval algorithm remain the same. The long term SBUV data record allows us to create a consistent, calibrated dataset of ozone profiles that can be used for climate studies and trend analyses. In particular, we focus on estimating the various sources of error in the SBUV profile ozone retrievals using independent observations and analysis of the algorithm itself. For the first time we include in the metadata a quantitative estimate of the smoothing error, defined as the error due to profile variability that the SBUV observing system cannot inherently measure. The magnitude of the smoothing error varies with altitude, latitude, season and solar zenith angle. Between 10 and 1 hPa the smoothing errors for the SBUV monthly zonal mean retrievals are of the order of 1 %, but start to increase above and below this layer. The largest smoothing errors, as large as 15-20%, were detected in in the troposphere. The SBUV averaging kernels, provided with the ozone profiles in version 8.6, help to eliminate the smoothing effect when comparing the SBUV profiles with high vertical resolution measurements, and make it convenient to use the SBUV ozone profiles for data assimilation and model validation purposes. The smoothing error can also be minimized by combining layers of data, and we will discuss recommendations for this approach as well. The SBUV ozone profiles have been intensively validated against satellite profile measurements obtained from the Microwave Limb Sounders (MLS) (on board the UARS and AURA satellites), Stratospheric Aerosol and Gas Experiment (SAGE) and Michelson Interferometer for Passive Atmospheric Sounding (MIPAS). Also, we compare coincident and collocated SBUV ozone retrievals with observations made by ground-based instruments, such as microwave spectrometers, lidars, Umkehr instruments and balloon-borne ozonosondes. Finally, we compare the SBUV ozone profiles with output from the NASA GSFC GEOS-CCM model. In the stratosphere between 25 and 1 hPa the mean biases and standard deviations are within 5% for monthly mean ozone profiles. Above and below this layer the vertical resolution of the SBUV algorithm decreases and the effects of vertical smoothing should be taken into account. Though the SBUV algorithm has a coarser vertical resolution in the lower stratosphere and troposphere, it is capable of precisely estimating the integrated ozone column between the surface and 25 hPa. The time series of the tropospheric - lower stratospheric ozone column derived from SBUV agrees within 5% with the corresponding values observed by an ensemble of ozone sonde stations in North Hemisphere. Drift of the ozone time series obtained from each SBUV(/2) instrument relative to ground based and satellite measurements are evaluated and some features of individual SBUV(l2) instruments are discussed. In addition to evaluating individual instruments against independent observations, we also focus on the instrument to instrument consistency in the series. Overall, Version 8.6 ozone profiles obtained from two different SBUV(l2) instruments compare within a couple of percent during overlap periods and are consistently varying in time, with some exceptions. Some of the noted discrepancies might bssociated with ozone diurnal variations, since the difference in the local time of the observations for a pair of SBUV(l2) instruments could be several hours. Other issues include the potential short-term drift in measurements as the instrument orbit drifts, and measurements are obtained at high solar zenith angles (>85 ). Based on the results of the validation, a consistent, calibrated dataset of SBUV ozone profiles has been created based on internal calibration only.

Kramarova, Natalya

A New SBUV Ozone Profile Time Series

Under NASA's MEaSUREs program for creating long term multi-instrument data sets, our group at Goddard has re-processed ozone profile data from a series of SBUV instruments. We have processed data from the Nimbus 7 SBUV instrument (1979-1990) and data from SBUV/2 instruments on NOAA-9 (1985-1998), NOAA-11 (1989-1995), NOAA-16 (2001-2010), NOAA-17 (2002-2010), and NOAA-18 (2005-2010). This reprocessing uses the version 8 ozone profile algorithm but now uses the Brion, Daumont, and Malicet (BMD) ozone cross sections instead of the Bass and Paur cross sections. The new cross sections have much better resolution, and extended wavelength range, and a more consistent temperature dependence. The re-processing also uses an improved cloud height climatology based on the Raman cloud retrievals of OMI. Finally, the instrument-to-instrument calibration is set using matched scenes so that ozone diurnal variation in the upper stratosphere does not alias into the ozone trands. Where there is no instrument overlap, SAGE and MLS are used to estimate calibration offsets. Preliminary analysis shows a more coherent time series as a function of altitude. The net effect on profile total column ozone is on average an absolute reduction of about one percent. Comparisons with ground-based systems are significantly better at high latitudes.

McPeters, Richard

Looking at Ozone From a New Angle: Shuttle Ozone Limb Sounding Experiment-2 (SOLSE-2)

The ozone layer above Earth is our planet's fragile sunscreen, protecting people, vegetation, and wildlife. NASA has been measuring ozone for more than 20 years by looking down, but SOLSE-2 will show that more information is available by looking at ozone from the side, at Earth's limb or atmospheric boundary. When the ozone layer is compromised, increased ultraviolet (UV) levels from the sun cause health problems ranging from severe sunburns to skin cancer and cataracts. A concerted global effort has been made to reduce or eliminate the production of chemicals that deplete ozone, but the ozone layer is not expected to recover for many decades because these chemicals can remain active in the atmosphere for up to 100 years. We know now that ozone monitoring needs to be focused in the lower stratosphere. The discovery of the ozone hole in 1985 demonstrated that very large changes in ozone were occurring in the lower stratosphere near 20 km, instead of the upper stratosphere as first expected, and where current ozone instruments are focused. Measuring ozone from a tangential perspective that is centered at the limb provides ozone profiles concentrated in the lower stratosphere. The first flight of SOLSE proved that this technique achieves the accuracy and coverage of traditional measurements, and surpasses the altitude resolution and depth of retrieval of conventional techniques. Results from the first flight convinced the science community to design the next generation ozone monitoring satellite based on SOLSE. The Ozone Mapping and Profiling Suite (OMPS) is currently being built for the NPOESS satellite. The primary objective of SOLSE-2 is to confirm the promising results of the first flight over a wider range of viewing conditions and spectral wavelengths. Sometimes a really hard problem can be solved when you look at it from a different angle! While scientists conduct research, protect yourself by observing the UV index and spend less unprotected time outdoors.

McPeters, Richard

Ozone Layer Observations

The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV and SAGE (Stratospheric Aerosol and Gas Experiment) instruments for example, show that the largest changes are occurring in the lower stratosphere and upper troposphere. The goal of ozone measurement in the next decades will be to document the predicted recovery of the ozone layer as CFC (chlorofluorocarbon) levels decline. This will require a continuation of global measurements of total column ozone on a global basis, but using data from successor instruments to TOMS. Hyperspectral instruments capable of measuring in the UV will be needed for this purpose. Establishing the relative roles of chemistry and dynamics will require instruments to measure ozone in the troposphere and in the stratosphere with good vertical resolution. Instruments that can measure other chemicals important to ozone formation and destruction will also be needed.

McPeters, Richard

On the Long-Term Calibration of the TOMS Total Ozone Record

Comparison of Total Ozone Mapping Spectrometer (TOMS) data to the network of ground-based Dobson/Brewer measurements reveals difference in the time dependence of the calibration of the two systems. We have been searching for a method to determine the time dependence of the TOMS calibrations that is independent of the Dobson/Brewer network. In a separate paper by DeLand et al., calibrations of the Solar Backscatter UV Spectrometer (SBUV) instruments have been rederived using the D-pair (306/313 nm wavelengths) data at the equator. These calibrations have been applied to the data from the Nimbus 7 SBUV and the NOAA 9 and 11 SBUV/2 data to derive a new version 7 data set for each instrument. We have used these data to do a detailed comparison to the Nimbus 7 and Earth Probe TOMS data. Assuming that the D-pair establishes the correct calibration, these comparisons reveal some small calibration drifts (approximately 1%) in the TOMS data. They also reveal an offset in the D-pair calibration with respect to the Dobson network of approximately 8 Dobson units with the Dobson being lower than the D-pair. The D-pair calibration offsets have been used to create a merged ozone data set from TOMS with a calibration that has been determined independent of the Dobson/Brewer network. Trend analyses of these data will be presented and compared to trend analyses using the ground-based data.

Stolarski, Richard S.

Some Long-Standing Issues Arising From Comparisons Between TOMS and The Ground-Based Ozone Network

Data from the series of Total Ozone Mapping Spectrometers (TOMS) have been compared to column ozone measurements taken by ground-based systems (Dobsons, Brewers and Filtermeters). On average, the comparisons show good agreement, with approximately 80% of the ground stations having less than a 2.5% standard deviation when compared to TOMS on a monthly mean basis. There are, however, differences that imply possible errors either in the TOMS ozone retrieval algorithm or in the basic assumptions used by the ground-based instruments. Some of the issues arising from these differences are: What are the relative calibrations of TOMS instruments? Why do the calibrations of the ground-based stations vary as much as they do with respect to TOMS as a transfer standard? Why are the TOMS data so much larger (approximately 6%) than the ground-based data in Antarctica and other ice-covered locations? Why is there seasonality in the difference between TOMS and ground-based stations in the Southern Hemisphere? Why are the differences a function of total ozone? Where and why are the differences a function of reflectivity? Why do some terrain and land-sea boundary features appear in the TOMS ozone data? The above issues will be highlighted by using data from TOMS and the ground stations. Plots of the individual station differences will be available.

Labow, Gordon J.

Merged Long-Term Data Sets from TOMS and SBUV Total Ozone Measurements

Total ozone has been measured by a series of nadir-viewing satellite instruments. These measurements begin with the Total Ozone Mapping Spectrometer (TOMS) and Solar Backscatter UltraViolet (SBUV) instruments on Nimbus 7, launched in late 1978. The measurements have continued with the Meteor 3 TOMS, Earth Probe TOMS, and NOAA 9,11,14 SBUV/2 instruments. The problem for producing a long-term data set is establishing the relative calibration of the various instruments to better than 1%. There was a nearly two year gap between the Meteor 3 TOMS and the Earth Probe TOMS. This gap is filled by the NOAA 9 and 11 SBUV/2 instruments, but they were in drifting orbits that result in effective gaps in the record when the equator crossing time occurs at large solar zenith angle. We have used recently re-derived calibrations of the SBUV instruments using the D-pair (306/313 nm wavelengths) data at the equator. These equatorial D-pair measurements should maintain the internal calibration of each instrument better than previous approaches. We then use the comparisons between instruments during their overlap periods to establish a consistent calibration over the entire data set. The resulting merged ozone data set is independent of the ground-based Dobson/Brewer network.

Stolarski, Richard