Search NASA⌕ Search

Engineering topics

Mccabe, M. E., Jr.

Publications and source records attributed to Mccabe, M. E., Jr..

Performance testing of a two-phase interface heat exchanger

This paper describes the design and performance testing of a heat exchanger which interfaces separate two-phase ammonia thermal loops. The basic design involves a tube-in-tube concept, with boiling occurring in the inner tube and condensation in the outer tube. Eight such tubes are arranged in parallel. Testing has demonstrated that up to 8.2 kW of heat may be transferred across the heat exchanger when the saturation temperature difference between the systems is 5 C. Performance of the heat exchanger is affected primarily by the mass flow rate of ammonia in the liquid supply loop.

Mccabe, M. E., Jr.↗

A high power spacecraft thermal management system

This paper describes the design and test results of an ammonia hybrid capillary pumped loop thermal control system. As a hytbrid, the system can operate as either a passive, capillary pumped loop, or, as a mechanically pumped system. The system is comprised of an evaporator section, a condenser section, 10 meters of liquid and vapor transport lines, a mechanical pump, and a reservoir. In the evaporator section, four capillary pumps are each integrated into three cold plates. The mechanical pump is installed in the liquid line and is in series with the capillary pumps. Testing has demonstrated that in the capillary pumped mode, the HPSTM can acquire and transport a total heat load of between 120 W and 24 kW, with a maximum heat flux density of 4.3 W/sq cm in the evaporator section. In the mechanically pumped configuration, a heat acquisition potential of 50 kW (9 W/sq cm heat flux density) has been demonstrated. The hybrid system still retains the proven capillary capabilities of temperature control, heat load sharing and fluid flow control between evaporator plates, rapid power cycling, and pressure priming recovery of deprimed evaporators.

Ku, J.↗

Test results of a pumped two-phase mounting plate with ammonia

The design, fabrication, and testing of full-scale prototype units of a two-phase mounting plate (TPMP), which will be used in a two-phase ammonia-based thermal control system for a large spacecraft, are described. The mounting plate uses an evaporator design in which liquid is mechanically pumped through porous feed tubes within the plate. The prototype TPMPs were tested with ammonia at heat loads over 3000 W (3.2 W/sq cm) and local heat fluxes of up to 4 W/sq cm. Calculated total heat transfer coefficients from these tests were between 0.8 and 1.0 W/sq cm per C. This represents a better than twenty-fold improvement over comparable single-phase heat transfer coefficients. Design diagrams are included.

Swanson, T. D.↗