Search NASA⌕ Search

Engineering topics

Mcdougal, J. N.

Publications and source records attributed to Mcdougal, J. N..

Occupational safety considerations with hydrazine fuels

A simple pharmacokinetic model and a specially designed dermal vapor exposure chamber which provides respiratory protection were used to determine the rate of penetration of hydrazine and 1,1-dimethylhydrazine (UDMH) vapor through the skin of rats. Parameters for the pharmacokinetic model were determined from intravenous and inhalation exposure data. The model was then used to estimate the skin permeation coefficient for hydrazine or UDMH vapor from the dermal-vapor exposure data. This analysis indicates that UDMH vapor has a relatively high permeability through skin (0.7 cm/hr), a value somewhat higher than was obtained for hydrazine by the same procedure (0.09 cm/hr). Based on these skin permeability results, a skin-only vapor exposure limit giving protection equivalent to the inhalation Threshold Limit Value (TLV) could be calculated. The current TLV's for UDMH and hydrazine are 0.5 and 0.1 ppm, respectively. The corresponding skin-only TLV equivalents, for personnel wearing respiratory protection, are 32 ppm for UDMH and 48 ppm for hydrazine. Should the proposed lowering to the TLV's for these compounds to 0.01 ppm be adopted, the equivalent skin-only TLV's would become 0.64 ppm for UDMH and 4.8 for hydrazine.

Clewell, H. J.↗