Search NASA⌕ Search

Engineering topics

Mclean, Thomas Donaldson

Publications and source records attributed to Mclean, Thomas Donaldson.

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectral measurements at the BNL NSLS-II synchrotron facility

During the first week of August 2022, Tim Gildea of Los Alamos National Laboratory’s (LANL) RP-SVS group performed a series of neutron spectral measurements at the National Synchrotron Light Source II (NSLS-II) 3GeV facility located at Brookhaven National Lab (BNL)1 . These measurements were conducted under Memorandum Purchase Order (MPO) 413911 with the objective of gaining an accurate understanding of the photoneutron fields generated under normal and selected fault conditions. The spectral data collected during the course of the study was analyzed at LANL and the results form the basis of this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation report on the Thermo Scientific TruDose (neutron,gamma) EPD3

This report summarizes an evaluation study on the Thermo Scientific TruDose n/γ EPD3 by LANL’s RP-SVS group. Two EPD3s were received for assessment (SNs 7500100 and 7500108) along with an EPD3 desktop reader. The evaluation included intercomparisons with Thermo’s N2 EPD which is in wide circulation at LANL but is no longer commercially available. A favourable assessment of the TruDose EPD3 would help support it as a viable option to replace the N2 EPD. The data and observations included in this report could also serve as the basis of a Technical Basis Document for the use of the EPD3 at LANL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Vessels Irradiation Experimental Campaign

The purpose of this report is to document the neutron flux field characterization experiments and to provide experiment data to validate radiation transport models. To predict material damage, irradiation experiments expose materials to known radiation fields to correlate the exposure to damage effects. As a part of irradiation experiments, the neutron field in the experiment must be well characterized; this characterization includes effects like room return. Only the neutron component of the 252 Cf sources is considered in theses measurements and calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Evaluation of the ASM2000 software

The ASM2000 software is based on the NetCAM3 software (currently installed at RLUOB) with the main difference being enhanced multi-CAM head support. Therefore, as the NetCAM3 software has been previously tested, the current evaluation concentrated on performance related to multi-head operation. In addition, bug fixes and improvements to prior versions of the NetCAM3 code were incorporated into the ASM2000 V2.0.0 software package.

97 MATHEMATICS AND COMPUTING↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

MCNP modelling of the Thermo SPA3 with Tungsten (Rees model) collimator

A Thermo Model SPA3 2”x2” NaI probe fitted with a Tungsten collimator has been modelled using MCNP6. The collimator was assumed to be machinable Tungsten which typically includes Ni and Fe. Various ratios of these additives are used in industry and for the purposes of these calculations the collimator was assumed to contain 7% Ni and 3% Fe with a density of 17.0 g/cm 3 . The dimensions of the collimator were based on measurements taken by Mike Fanning. The above detector model was used, in a manner similar to the approach described in LA-UR-19-32358, to calculate photopeak count rates per unit activity per unit area (i.e. cpm per pCi/cm 2 ) conversion factors for various contamination scenarios.

61 RADIATION PROTECTION AND DOSIMETRY↗