Stabilization of X-ray Beam for Nanoimaging Using Source Electron Fast Orbit Feedback
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Mead, J..
Explore the source record for details and available documents.
The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.
Explore the source record for details and available documents.
An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.
In this study, we have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. Lastly, the detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.
In this paper, we have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. Finally, we will discuss the technical details of the systems, and present some of the results from them.
Explore the source record for details and available documents.
N/A
The first eight insertion devices (IDs) at the NSLS-II were commissioned during the fall run of 2014. In this paper we discuss commissioning of the synchrotron radiation protection (SRP) system and beamline frontends (FE) for the respective IDs. We describe the diagnostics utilized if FE commissioning and a procedure that was used for the alignment of the photon beam from insertion devices in the beamline frontends. Then we discuss the current status of the SRP system and operation of the commissioned frontends.
A radiometer that uses aperture synthesis in two dimensions is being built as part of research under NASA's Instrument Incubator Program. The instrument development team consists of engineers at the Goddard Space Flight Center, the University of Massachusetts and Quadrant Engineering. This will be an aircraft instrument operating at L-band which builds on the heritage of ESTAR. The choice of L-band was made because the problem of achieving adequate resolution in space is most critical at this wavelength and because a polarimetric, conical scanning airborne radiometer for future experiments to validate soil moisture and ocean salinity retrieval algorithms is not currently available. The instrument will be designed to fly on the NASA P-3 aircraft in a nadir pointing mode, although other options are possible. The antenna will consist of an array of modules arranged in a rectangular grid. Each module will be comprised of a printed circuit dual-polarized patch and integrated receiver. The distribution of modules within the rectangular array will be adjustable so that several different imaging configurations (e.g. "+","Y", "T") can be employed. The integrated receiver will provide amplification and conversion to IF. The IF signal will be routed to a processor where the required correlations performed. The I and Q channels will be created digitally and the correlations will be done digitally in this processor. The digitization will be done with sufficient bits to study the effects of quantization on radiometer performance. A computer/controller will store the data for conversion to an image and will also perform temperature control and other data interfacing and housekeeping tasks. The instrument is currently in the bread boarding phase of development. A design of the critical components has been completed and hardware is being assembled to test the individual elements. It is expected that a complete 2-channel correlator will be tested by the summer of 2000 and that the complete instrument will be ready for flight tests the following summer (2001).
A table of correspondence SAO-HD-DM-GC was prepared by Morin (1973). The machine-readable version of this cross identification was obtained from the Centre de Donnees Stellaires (Strasbourg, France). The table was sorted at the Goddard Space Flight Center by HD number and all blank HD number records were removed to produce the HD-SAO-DM table presented. There were 258997 entries in the original table; there are 180411 entries after removing the blank HD records. The Boss General Catalogue (GC) numbers were retained on the machine-readable version after the sort.
The paper describes a stellar data retrieval system for which the data base consists of 28 machine-readable astronomical catalogs. Eleven of these catalogs have been combined into the Goddard Cross Index (GCI), which serves as the computer entry point to these catalogs. The full data entry from any of the GCI catalogs can be retrieved in a single computer run. With this system, it is possible to prepare candidates for observation by searching the data base for stars with given characteristics. Generation of plots of all catalog stars in or near the telescope's field of view to scale of Palomar, other atlases, or to the telescope itself for use as observing charts or to aid in identifying unknown sources, can be accomplished.
Atelectatic and direct toxic effects of oxygen on human subjects