Search NASA⌕ Search

Engineering topics

Meaney, K. D.

Publications and source records attributed to Meaney, K. D..

Dynamics and Power Balance of Near Unity Target Gain Inertial Confinement Fusion Implosions

The change in the power balance, temporal dynamics, emission weighted size, temperature, mass, and areal density of inertially confined fusion plasmas have been quantified for experiments that reach target gains up to 0.72. It is observed that as the target gain rises, increased rates of self-heating initially overcome expansion power losses. This leads to reacting plasmas that reach peak fusion production at later times with increased size, temperature, mass and with lower emission weighted areal densities. Analytic models are consistent with the observations and inferences for how these quantities evolve as the rate of fusion self-heating, fusion yield, and target gain increase. At peak fusion production, it is found that as temperatures and target gains rise, the expansion power loss increases to a near constant ratio of the fusion self-heating power. Finally, this is consistent with models that indicate that the expansion losses dominate the dynamics in this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for suprathermal ion distribution in burning plasmas

At the National Ignition Facility, inertial confinement fusion experiments aim to burn and ignite a hydrogen plasma to generate a net source of energy through the fusion of deuterium and tritium ions. The energy deposited by α-particles released from the deuterium–tritium fusion reaction plays the central role in heating the fuel to achieve a sustained thermonuclear burn. In the hydrodynamic picture, α-heating increases the temperature of the plasma, leading to increased reactivity because the mean ion kinetic energy increases. Therefore, the ion temperature is related to the mean ion kinetic energy. In this report we use the moments of the neutron spectrum to study the relationship between the ion temperature (measured by the variance in the neutron kinetic energy spectrum) and the ion mean kinetic energy (measured by the shift in the mean neutron energy). We observe a departure from the relationship expected for plasmas where the ion relative kinetic energy distribution is Maxwell–Boltzmann, when the plasma begins to burn. Understanding the cause of this departure from hydrodynamic behaviour could be important for achieving robust and reproducible ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A combined MeV-neutron and x-ray source for the National Ignition Facility

We report that in support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF’s long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal > 1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 13 n/cm 2 and an x-ray dose of 7 krad.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of Hydrodynamic Flows in Imploding Fusion Plasmas on the National Ignition Facility [plus supplemental information]

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. In this work, we present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving record hot spot energies with large HDC implosions on NIF in HYBRID-E

HYBRID-E is an inertial confinement fusion implosion design that increases energy coupled to the hot spot by increasing the capsule scale in cylindrical hohlraums while operating within the current experimental limits of the National Ignition Facility. HYBRID-E reduces the hohlraum scale at a fixed capsule size compared to previous HYBRID designs, thereby increasing the hohlraum efficiency and energy coupled to the capsule, and uses the cross-beam energy transfer (CBET) to control the implosion symmetry by operating the inner (23° and 30°) and outer (44° and 50°) laser beams at different wavelengths (Δλ> 0). Small case to capsule ratio designs can suffer from insufficient drive at the waist of the hohlraum. We show that only a small amount of wavelength separation between the inner and outer beams (Δλ1-2 Å) is required to control the symmetry in low-gas-filled hohlraums (0.3 mg/cm3 He) with enough drive at the waist of the hohlraum to symmetrically drive capsules 1180 μm in outer radius. This campaign is the first to use the CBET to control the symmetry in 0.3 mg/cm3 He-filled hohlraums, the lowest gas fill density yet fielded with Δλ> 0. We find a stronger sensitivity of hot spot P2 in μm per Angstrom (40–50 μm/Å wavelength separation) than observed in high-gas-filled hohlraums and previous longer pulse designs that used a hohlraum gas fill density of 0.6 mg/cm3. There is currently no indication of transfer roll-off with increasing Δλ, indicating that even longer pulses or larger capsules could be driven using the CBET in cylindrical hohlraums. We show that the radiation flux symmetry is well controlled during the foot of the pulse, and that the entire implosion can be tuned symmetrically in the presence of the CBET in this system, with low levels of laser backscatter out of the hohlraum and low levels of hot electron production from intense laser–plasma interactions. Radiation hydrodynamic simulations can accurately represent the early shock symmetry and be used as a design tool, but cannot predict the late-time radiation flux symmetry during the peak of the pulse, and semi-empirical models are used to design the experiments. Deuterium–tritium (DT)-layered tests of 1100 μm inner radius implosions showed performance close to expectations from simulations at velocities up to ~360 km/s, and record yields at this velocity, when increasing the DT fuel layer thickness to mitigate hydrodynamic mixing of the ablator into the hot spot as a result of defects in the ablator. However, when the implosion velocity was increased, mixing due to these defects impacted performance. The ratio of measured to simulated yield for these experiments was directly correlated with the level of observed mixing. These simulations suggest that reducing the mixing, e.g., by improving the capsule defects, could result in higher performance. In addition, future experiments are planned to reduce the coast time at this scale, delay between the peak compression and the end of the laser, to increase the hot spot convergence and pressure. To reduce the coast time by several hundred ps compared to the 1100 μm inner radius implosions, HYBRID-E has also fielded 1050 μm inner radius capsules, which resulted in higher hot spot pressure and a fusion energy yield of ~170 kJ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid Cherenkov detector for studying nucleosynthesis in inertial confinement fusion

Measuring gamma rays emitted from nuclear reactions gives insight into their nuclear structure. Notably, there are several nuclear reactions that produce gamma rays at ~1 MeV–3 MeV energies such as T( 4 He, γ) 7 Li, 4 He( 3 He, γ) 7 Be, and 12 C(p, γ) 13 N, which may solve questions lingering about big-bang nucleosynthesis and stellar nucleosynthesis. To observe 1 MeV–3 MeV gamma rays in an inertial confinement fusion system, a new style of the Cherenkov detector was developed using aerogel and fused silica as a Cherenkov medium. Utilizing the OMEGA laser facility, both aerogel and fused silica media were compared with the existing gas-medium Cherenkov detector to validate the concept. Furthermore, gamma ray measurements from high yield inertial confinement fusion implosions (deuterium–tritium and deuterium– 3 He) demonstrated that aerogel and fused silica were viable Cherenkov media, paving the way for a potential optimized detector to make these cross section measurements on OMEGA or the National Ignition Facility.

47 OTHER INSTRUMENTATION↗

Diagnostic signature of the compressibility of the inertial-confinement-fusion pusher

In this study, carbon shell areal density measurements from many types of inertial confinement fusion implosions at the National Ignition Facility (NIF) demonstrate that the final state of the outside portion of the shell is set primarily by capsule coast time, the coasting period between main laser shut off and peak fusion output. However, the fuel areal density does not correlate with the increasing carbon compression. While two-dimensional (2D) radiation-hydrodynamic simulations successfully capture the carbon compression, energy must be added to the simulated fuel-ice layer to reproduce fuel areal density measurements. The data presented demonstrates that the degradation mechanisms that reduce the compressibility of the fuel do not reduce the compressibility of the ablator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗