Search NASA⌕ Search

Engineering topics

Mehti Koklu

Publications and source records attributed to Mehti Koklu.

At least 19 records

Semispan Test Results of an Active Flow Control Enabled High-Lift Common Research Model in Landing Configuration

A 10%-scale semispan, Active Flow Control (AFC) enabled, simplified high-lift version of the Common Research Model (CRM-SHL-AFC) was tested in the 14- by 22-Foot Subsonic Tunnel at the NASA Langley Research Center. The main objective of the test was to develop an AFC system that can provide the necessary lift recovery on a simple-hinged flap high-lift system while minimizing its pneumatic power requirement. Three new types of AFC approaches were examined: Double-Row Sweeping Jets (DRSWJ), Alternating Pulsed Jets (APJ), and High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used an upstream row of sweeping jets combined with a downstream row of steady jets to overcome strong adverse pressure gradients. The test was conducted mostly at a freestream Mach number of 0.20. For exploration purposes, a limited number of runs were made at lower Mach numbers or using vortex generators (VGs). Minimal sensitivity to Mach number or VGs, for the cases evaluated, were observed. The AFC-induced lift coefficient increment was maintained over the AFC-off case for most flow-control cases examined. The CRM-SHL-AFC configuration equipped with HELP actuation was the only actuator configuration able to match or exceed the targeted lift performance of a reference conventional high-lift configuration. The presented aerodynamic data include lift, drag, and pitching moment coefficients as a function of angle of attack, with and without the Transonic Wall Interference Correction System (TWICS) method applied. Lift increments as a function of AFC pneumatic power usage (i.e., nozzle pressure ratio, mass flow, momentum coefficient, and power coefficient) are also presented at a lower angle of attack (α = 8.9°) and at maximum lift (α= 17.1°). At the two angles of attack, the surface pressure distributions and autospectral densities from the unsteady pressure transducers for the AFC-off case and the best HELP actuation case are compared.

high-lift↗

Semispan Test Results of a Conventional High-Lift Common Research Model in Landing Configuration

A 10%-scale high-lift version of the Common Research Model (CRM-HL) was tested in the 14- by 22-Foot Subsonic Tunnel at the NASA Langley Research Center. This research was aimed at providing a representative reference case for comparison with an Active Flow Control (AFC) enabled version of the CRM-HL and to increase the existing experimental database for CFD high-lift prediction. The test was conducted mostly at a freestream Mach number of 0.20. The effects of the engine nacelle, nacelle chine, tufts, small variations in Mach number, hysteresis-associated increasing/decreasing angle of attack, and incoming floor boundary-layer thickness (i.e., thinning by activation of the floor boundary layer removal system) were examined. A prestall lift performance degradation for the CRM-HL configuration was resolved with a properly placed nacelle chine. Surface pressure results are presented in detail for three key variants of CRM-HL — baseline (nacelle on), nacelle off, and nacelle with the most effective chine installation. The presented aerodynamic forces and surface pressures include both with and without the wall correction using the Transonic Wall Interference Correction System (TWICS) method. A limited set of photogrammetry results is also presented to document the model deformation under test conditions.

high-lift↗

A New Method for Predicting Turbulent Flow Reattachment Location: Application of Stratford Criterion for Reattaching Flows

A new method for predicting turbulent flow reattachment location has been developed. The method predicts the reattachment location using the surface static pressure distribution and requires only a single empirical parameter. The method is based on the well-known Stratford’s flow separation criterion, which results from an approximate solution to the equations of motion within the boundary layer. Because of the large pressure rise, the original Stratford separation criterion is not valid for reattaching flows. In order to apply the Stratford criterion for reattaching flows, the reference location was moved to the pressure drop conditions instead of pressure rise conditions. In addition, the pressure distribution was scaled using a technique that was originally introduced for supersonic base flows. A new empirical parameter was also obtained for the modified Stratford criterion. The method has been tested for 30 different separated flow configurations from the literature. The variety of test cases include subsonic flows, transonic flows, 2D flows, and axisymmetric flows, with experimental as well as high resolution numerical simulation results. The flow reattachment predictions with the new method agree very well with the reported data. The error is less than 5% and typically about 2%. The new method is an extremely simple and a quick way of finding the reattachment location. Given the complexities of the existing experimental techniques for finding the reattachment location, the method easily and quickly provides the flow reattachment location, which could be used to estimate the physical extent of separation bubbles, as a performance index for flow control methods, or to assess the predictive capability of turbulence models.

Flow reattachment location↗

Performance Assessment of Fluidic Oscillators Tested on the NASA Hump Model

Flow separation control over a wall-mounted hump model was studied experimentally to assess the performance of fluidic oscillators (sweeping jet actuators). An array of fluidic oscillators was used to control flow separation. The results showed that the fluidic oscillators were able to achieve substantial control over the separated flow by increasing the upstream suction pressure and downstream pressure recovery. Using the data available in the literature, the performance of the fluidic oscillators was compared to other active flow control (AFC) methods such as steady blowing, steady suction, and zero-net-mass-flux (ZNMF) actuators. Several integral parameters, such as the inviscid flow comparison coefficient, pressure drag coefficient, and modified normal force coefficient, were used as quality metrics in the performance comparison of the AFC methods. These quality metrics indicated the superiority of the steady suction method, especially at lower excitation amplitudes that is followed by the fluidic oscillators, steady blowing, and the ZNMF actuators, respectively. An aerodynamic figure of merit (AFM) was also constructed using the integral parameters and AFC power usage. The AFM results revealed that, for this study, steady suction was the most efficient AFC method at lower excitation amplitudes. The steady suction loses its efficiency as the excitation amplitude increases, and the fluidic oscillators become the most efficient AFC method. Both the steady suction and the fluidic oscillators have an AFM > 1 for the range tested in this study, indicating that they provide a net benefit when the AFC power consumption is also considered. On the other hand, both the steady blowing and ZNMF actuators were found to be inefficient AFC methods (AFM < 1) for the current configuration. Although they improved the flow field by controlling flow separation, the power requirement was more than their benefit.

Fluidic oscillators↗

Wind Tunnel Testing of High Efficiency Low Power (HELP) Actuation for Active Flow Control

A High Efficiency Low Power (HELP) methodology has been successfully developed and tested on an active flow control (AFC) version of the 10%-scale high-lift Common Research Model (CRM-HL) at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel (14x22). The AFC variant of the CRM-HL, designated as CRM-SHL-AFC, was integrated with modular HELP actuator cartridges on the shoulder of its highly deflected (≥50°) simplehinged flaps. A reference conventional CRM-HL configuration equipped with Fowler flaps and a nacelle chine was chosen to provide the targeted lift enhancement goals and for comparison with the results of the CRM-SHL-AFC. The current data are presented with the Transonic Wall Interference Correction System (TWICS) method applied. The HELP actuators, which use a combination of unsteady sweeping jets and steady discrete jets in tandem, were designed to overcome strong adverse pressure gradients, while minimizing the pneumatic power usage. The power coefficient (C(sub π)), which takes account of both supply air pressure and mass flow usage for the AFC actuators, is a useful parameter for judging the actuators’ performance efficiency and perhaps for scaling-up of the AFC system. Full HELP actuation coverage with a constant spanwise nozzle pressure ratio (NPR) was able to achieve the lift enhancement goals for the entire lift curve and was found to be the most effective AFC case. For the most effective case, mass flow rates greater than ~0.91 lbm/s and NPR values greater than ~1.8 (corresponding to C(sub π) = 0.18) are needed to achieve the lift enhancement goal at α = 9°, whereas mass flow rates greater than ~1.23 lbm/s and NPR values greater than ~2.3 (corresponding to C(sub π) = 0.3) are needed to achieve the lift enhancement goal at α = 17°. Surface pressure distributions indicate that the HELP actuation on the flap shoulder increased the suction pressures (and flow circulation) globally in both the streamwise and the spanwise directions, and thereby enhanced the lift over the entire high-lift system. The CRM-SHLAFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional CRM-HL, thus meeting the objective of the research.

John C Lin↗

Mitigation of Nacelle/Pylon Wake on the High-Lift Common Research Model Using a Nacelle Chine

A 10% scale, high-lift version of the Common Research Model (CRM-HL) was tested in the NASA Langley Research Center 14-by22-Foot Subsonic Tunnel. The focus of the wind tunnel test campaign was to assess the feasibility of active flow control (AFC) on the simplified CRM-HL configuration. The modular design of the CRM-HL model enabled the testing of the conventional CRM-HL version to establish a benchmark for the AFC research. The wind tunnel model has the capability of being tested with and without the engine nacelle/pylon for comparison. The wind tunnel investigation included the acquisition of force and moment data, steady pressure data, as well as surface flow visualization using minitufts. For some select cases, numerical simulations were performed to aid in understanding the wind tunnel data. Wind tunnel measurements indicated a lift degradation of the conventional CRM-HL at high angles of attack. The surface flow visualization with fluorescent minitufts revealed that the lift degradation is due to flow separation caused by the nacelle/pylon wake on the inboard wing. The wake and the consequent flow separation were successfully mitigated using a nacelle chine installed on the inboard side of the engine nacelle.

Mehti Koklu↗

Unsteady Pressure Measurement on a Simplified High-Lift Configuration of the Common Research Model using Active Flow Control

The High-Lift Common Research Model (CRM-HL) is a product of the NASA Advanced Air Transport Technology (AATT) Project intended to study various high-lift aerodynamic phenomena including enhanced lift, acoustic noise generation, and optimum placement of leading and trailing-edge devices. The current study was conducted in the NASA Langley 14-by 22-Foot Subsonic Tunnel (14x22) for the purpose of evaluating enhanced lift through the use of active flow control (AFC). The current paper documents the effect of sweeping-jet actuation combined with steady blowing on a simplified high-lift configuration using unsteady pressure measurements. The time-series parameters for the measurements are documented as well as the data acquisition system used to acquire the data. An uncertainty analysis will be presented in order to document the system performance and provide an estimate of the data quality. Repeatability of the data will be shown along with trends associated with model angle of attack, and those associated with changes in the nozzle pressure ratio (NPR) of the AFC system.

Common Research Model↗

Unsteady Pressure Measurements on a Simplified High-Lift Configuration of the Common Research Model using Active Flow Control

The High-Lift Common Research Model (CRM-HL) is a product of the NASA Advanced Air Transport Technology (AATT) Project intended to study various high-lift aerodynamic phenomena including enhanced lift, acoustic noise generation, and optimum placement of leading and trailing-edge devices. The current study was conducted in the NASA Langley 14-by 22-Foot Subsonic Tunnel (14x22) for the purpose of evaluating enhanced lift through the use of active flow control (AFC). The current paper documents the effect of sweeping-jet actuation combined with steady blowing on a simplified high-lift configuration using unsteady pressure measurements. The time-series parameters for the measurements are documented as well as the data acquisition system used to acquire the data. An uncertainty analysis will be presented in order to document the system performance and provide an estimate of the data quality. Repeatability of the data will be shown along with trends associated with model angle of attack, and also those associated with changes in the nozzle pressure ratio (NPR) of the AFC system.

Active Flow Control↗

A Method for Obtaining Surface Flow Vectors and Its Implementation in Interferometric Skin Friction Measurement

A new method was developed to extract surface flow vectors from an oilflow visualization image that has oil streaklines. The method is analogous to the PIV processing where the image is divided into interrogation windows. A representative flow direction is obtained for each interrogation window using image processing with a line-detection algorithm. Repeating the process for the entire image, one can find the surface vector field. The Hough transformation, Radon transformation and Machine Learning were used as line-detection algorithms. The obtained vector field is then postprocessed to filter spurious vectors and to apply smoothing. The method was tested on 2D and 3D models with different flow complexities. The method was able to predict surface flow vectors for all cases tested. The predicted surface flow vectors were used in obtaining the surface skin friction. The successful implementation of the surface flow vectors enables interferometric skin friction measurements on surfaces beneath 3D complex flows. In addition, the surface flow vectors can be superimposed on the oilflow visualization images to better explain the surface flow topology.

Surface flow vectors↗

A Method for Obtaining Surface Flow Vectors and Its Implementation in Interferometric Skin Friction Measurement

A new method was developed to extract surface flow vectors from an oilflow visualization image that has oil streaklines. The method is analogous to the PIV processing where the image is divided into interrogation windows. A representative flow direction is obtained for each interrogation window using image processing with a line-detection algorithm. Repeating the process for the entire image, one can find the surface vector field. The Hough transformation, Radon transformation and Machine Learning were used as line-detection algorithms. The obtained vector field is then postprocessed to filter spurious vectors and to apply smoothing. The method was tested on 2D and 3D models with different flow complexities. The method was able to predict surface flow vectors for all cases tested. The predicted surface flow vectors were used in obtaining the surface skin friction. The successful implementation of the surface flow vectors enables interferometric skin friction measurements on surfaces beneath 3D complex flows. In addition, the surface flow vectors can be superimposed on the oilflow visualization images to better explain the surface flow topology.

Surface flow vectors↗

Flow Physics Study of Sweeping Jet Actuation on a NACA 0015 Swept Wing Configuration

Preliminary results from a recently completed active flow control (AFC) experiment on a 30 deg swept, semispan wing are presented. The constant chord NACA 0015 wing is configured with sweeping jet actuators at the flap shoulder to study the effects of excitation introduced into a separated, three-dimensional flowfield. The research is aimed at developing efficient active flow control approaches for swept wing configurations. Oil and tuft flow visualization data, steady and unsteady pressure data, particle image velocimetry (PIV), oil flow interferometry (OFI), and force and moment data are used to compare the flowfields with and without AFC. The parameters that were varied include freestream velocity, actuator momentum coefficient, and flap deflection angle.

active flow control↗

Flow Physics Study of Sweeping Jet Actuation on an NACA 0015 Swept Wing Configuration

Results from a recently completed active flow control (AFC) experiment on a low aspect ratio, AR = 4.35, 30 degree swept, semispan wing with a 30% chord trailing edge flap are presented. The constant chord NACA 0015 wing is configured with sweeping jet actuators at the flap shoulder to facilitate our study of three-dimensional, swept wing separated and AFC controlled flowfields on the flap. Two flap deflection angles (delta_f = 0 degrees and 20 degrees) are examined. Oil and tuft flow visualization data, steady and unsteady pressure data, and particle image velocimetry (PIV) complement the balance lift and drag data. These results are used to examine smooth body separation, fixed separation, and the AFC-controlled flap flowfield downstream of a sweeping jet actuator. A momentum coefficient of 1.1% reattaches the flow to the flap surface when flap delta_f = 20 degrees increasing lift by approximately 0.26. This fundamental study is a first step in a research effort focused on improving the efficiency of AFC systems for swept wing applications.

active flow control↗

Skin Friction Measurement on a Swept NACA 0015 Wing Using Oil Film Interferometry

An application of oil film interferometry (OFI) to measure skin friction on the 3D flow over an NACA 0015 airfoil with 30° of sweep is presented. Local flow direction must be known to apply OFI to complex 3D flows such as this. A recently developed surface flow vector extraction method was integrated into the OFI analysis algorithm. Surface flow vectors were used to calculate the surface streamlines and hence provided local flow direction to the OFI analysis. After calibration using photogrammetry, the surface flow vectors also enabled decomposition of the skin friction coefficient into different components (such as chordwise and spanwise). The presented method successfully measured skin friction at locations with different flow characteristics such as high skin friction regions, strong spanwise flow regions, and 3D flow separated regions. In the current OFI analysis, multiple interferogram images acquired at different times were analyzed for the same location. The multiple interferogram analysis enabled averaging, which reduced the scatter the skin friction data. The results presented herein demonstrate the capability of the current approach, thereby extending OFI skin friction measurements to complex 3D flows.

Skin friction measurement↗

Wind Tunnel Testing of AFC over a Deflected Aileron on the High-Lift Common Research Model

Active flow control (AFC) using discrete fluidic actuators distributed along the span, just upstream of the deflected aileron of the 10% scale high-lift version of the Common Research Model (CRM-HL), was evaluated during a wind tunnel test in the NASA Langley 14- by 22-Foot Subsonic Tunnel. For this set of experiments, a new outboard section was fabricated incorporating a deflectable aileron. Aileron deflection angles of 0, 7.5, 16, and 25 were investigated. This experimental investigation is in response to a recent study by Boeing potential to use AFC with a drooped aileron during takeoff to improve lift-to-drag ratio (L/D) by as much as 5%, depending on AFC mass flow rate. AFC is used at deflection angles above the nominal deflection of 7.5 to control the resulting flow separation that occurs and potentially improve L/D. Improvements in aircraft low-speed L/D can affect vehicle range and/or payload. Tuft flow visualization data, steady and unsteady surface pressure data, and force and moment data are used to compare the flowfields with and without AFC. Parameters varied include actuator momentum coefficient and aileron deflection angle. The surface pressure and tuft flow visualization results indicate that without AFC, the flow over a majority of the aileron upper surface is separated for aileron deflection angles larger than 7.5. When AFC is applied, the flow is reattached to the aileron. Force and moment results show that a local increase in lift leads to an increase in L/D of at least 3.5% using mass flow rates thought to be available from air sources onboard a commercial transport.

AFC↗

Skin Friction Measurement on a Swept NACA 0015 Wing Using Oil Film Interferometry

An application of oil film interferometry (OFI) to measure skin friction on the 3D flow over an NACA 0015 airfoil with 30° of sweep is presented. Local flow direction must be known to apply OFI to complex 3D flows such as this. A recently developed surface flow vector extraction method was integrated into the OFI analysis algorithm. Surface flow vectors were used to calculate the surface streamlines and hence provided local flow direction to the OFI analysis. After calibration using photogrammetry, the surface flow vectors also enabled decomposition of the skin friction coefficient into different components (such as chordwise and spanwise). The presented method successfully measured skin friction at locations with different flow characteristics such as high skin friction regions, strong spanwise flow regions, and 3D flow separated regions. In the current OFI analysis, multiple interferogram images acquired at different times were analyzed for the same location. The multiple interferogram analysis enabled averaging, which reduced the scatter the skin friction data. The results presented herein demonstrate the capability of the current approach, thereby extending OFI skin friction measurements to complex 3D flows.

Skin friction measurement↗