Search NASA⌕ Search

Engineering topics

Mendell, Mark J.

Publications and source records attributed to Mendell, Mark J..

A Research Agenda on Assessing and Remediating Home Dampness and Mold to Reduce Dampness-Related Health Effects

This report briefly summarizes, based on recent review articles and selected more recent research reports, current scientific knowledge on two topics: assessing unhealthy levels of indoor D/M in homes and remediating home dampness-related problems to protect health. Based on a comparison of current scientific knowledge to that required to support effective, evidence-based, health-protective policies on home D/M, gaps in knowledge are highlighted, prior questions and research questions specified, and necessary research activities and approaches recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Research Agenda on Assessing and Remediating Home Dampness and Mold to Reduce Dampness-Related Health Effects

This report briefly summarizes, based on recent review articles and selected more recent research reports, current scientific knowledge on two topics: assessing unhealthy levels of indoor D/M in homes and remediating home dampness-related problems to protect health. Based on a comparison of current scientific knowledge to that required to support effective, evidence-based, health-protective policies on home D/M, gaps in knowledge are highlighted, prior questions and research questions specified, and necessary research activities and approaches recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A longitudinal study of ventilation rates in California office buildings and self-reported occupant outcomes including respiratory illness absence

Limited evidence has associated lower ventilation rates (VRs) in offices with higher illness-related absence rates. We studied spaces in office buildings, selected without knowledge of their VRs, in three California climate zones. In each study space, real-time logging sensors measured carbon dioxide and thermal parameters for one year. Web-based surveys every three months collected data on occupants’ health outcomes. Using multivariate models, relationships were assessed between CO 2 concentrations, or VRs estimated from CO 2 , and adverse occupant outcomes including respiratory infections and illness absences. For all outcomes, positive associations were hypothesized with higher CO 2 levels (and negative associations with higher VRs). Low survey response limited sample size and study power. In the 16 study spaces, CO 2 concentrations were uniformly low over the year, and most estimated VRs ranged from twice to nine times the California office minimum VR standard (7 L/s or 15 cfm per person). Primary CO 2 and VR metrics had no statistically significant relationships with occupant outcomes. Within the observed range of uniformly low CO 2 and high VRs (mostly 16–42 L/s per person), little variation in contaminant concentrations would be expected, which would explain lack of relationships with occupant outcomes. These high VRs resulted partly from frequently used energy-saving “economizer” cycles in moderate California climates, but VRs at other times also substantially exceeded required VRs. These findings suggest, consistent with theory, that within a higher VR range, increased VRs do not reduce respiratory illness. Further studies are needed to better characterize such relationships.

60 APPLIED LIFE SCIENCES↗

Indoor Environmental Exposures and Exacerbation of Asthma: An Update to the 2000 Review by the Institute of Medicine

Background: Previous research has found relationships between specific indoor environmental exposures and exacerbation of asthma. Objectives: In this review we provide an updated summary of knowledge from the scientific literature on indoor exposures and exacerbation of asthma. Methods: Peer-reviewed articles published from 2000 to 2013 on indoor exposures and exacerbation of asthma were identified through PubMed, from reference lists, and from authors’ files. Articles that focused on modifiable indoor exposures in relation to frequency or severity of exacerbation of asthma were selected for review. Research findings were reviewed and summarized with consideration of the strength of the evidence. Results: Sixty-nine eligible articles were included. Major changed conclusions include a causal relationship with exacerbation for indoor dampness or dampness-related agents (in children); associations with exacerbation for dampness or dampness-related agents (in adults), endotoxin, and environmental tobacco smoke (in preschool children); and limited or suggestive evidence for association with exacerbation for indoor culturable Penicillium or total fungi, nitrogen dioxide, rodents (nonoccupational), feather/down pillows (protective relative to synthetic bedding), and (regardless of specific sensitization) dust mite, cockroach, dog, and dampness-related agents. Discussion: This review, incorporating evidence reported since 2000, increases the strength of evidence linking many indoor factors to the exacerbation of asthma. Conclusions should be considered provisional until all available evidence is examined more thoroughly. Conclusion: Multiple indoor exposures, especially dampness-related agents, merit increased attention to prevent exacerbation of asthma, possibly even in nonsensitized individuals. Additional research to establish causality and evaluate interventions is needed for these and other indoor exposures.

60 APPLIED LIFE SCIENCES↗

Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each specific outcome threshold are estimated; and the highest of these MVRs, which would then meet all outcome thresholds, is selected as the target MVR. In a second step, implemented only if the target MVR from step 1 is judged impractically high, costs and benefits are estimated and this information is used in a risk management process. Four human outcomes with substantial quantitative evidence of relationships to VRs are identified for initial consideration in setting MVR standards. These are: building-related symptoms (sometimes called sick building syndrome symptoms), poor perceived indoor air quality, and diminished work performance, all with data relating them directly to VRs; and cancer and non-cancer chronic outcomes, related indirectly to VRs through specific VR-influenced indoor contaminants. In an application of step 1 for offices using a set of example outcome thresholds, a target MVR of 9 L/s (19 cfm) per person was needed. Because this target MVR was close to MVRs in current standards, use of a cost/benefit process seemed unnecessary. Selection of more stringent thresholds for one or more human outcomes, however, could raise the target MVR to 14 L/s (30 cfm) per person or higher, triggering the step 2 risk management process. Consideration of outdoor air pollutant effects would add further complexity to the framework. For balancing the objective and subjective factors involved in setting MVRs in a cost-benefit process, it is suggested that a diverse group of stakeholders make the determination after assembling as much quantitative data as possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand controlled ventilation and classroom ventilation

This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗