Search NASA⌕ Search

Engineering topics

Meng, Y.

Publications and source records attributed to Meng, Y..

At least 19 records

The Surface-Topography Challenge: A Multi-Laboratory Benchmark Study to Advance the Characterization of Topography

Surface performance is critically influenced by topography in virtually all real-world applications. The current standard practice is to describe topography using one of a few industry-standard parameters. The most commonly reported number is Ra, the average absolute deviation of the height from the mean line (at some, not necessarily known or specified, lateral length scale). However, other parameters, particularly those that are scale-dependent, influence surface and interfacial properties; for example the local surface slope is critical for visual appearance, friction, and wear. The present Surface-Topography Challenge was launched to raise awareness for the need of a multi-scale description, but also to assess the reliability of different metrology techniques. In the resulting international collaborative effort, 153 scientists and engineers from 64 research groups and companies across 20 countries characterized statistically equivalent samples from two different surfaces: a “rough” and a “smooth” surface. The results of the 2088 measurements constitute the most comprehensive surface description ever compiled. We find wide disagreement across measurements and techniques when the lateral scale of the measurement is ignored. Consensus is established through scale-dependent parameters while removing data that violates an established resolution criterion and deviates from the majority measurements at each length scale. Our findings suggest best practices for characterizing and specifying topography. The public release of the accumulated data and presented analyses enables global reuse for further scientific investigation and benchmarking.

42 ENGINEERING↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The structure of sc16 GaP obtained at 17.5 GPa and 1400 K

We report using a laser-heated diamond anvil cell, a powdered sample of gallium phosphide was compressed to 17.5 GPa and heated up to 1400 K. The material obtained was characterized at room temperature using synchrotron x-ray diffraction. Experimental results were compared with first-principles calculations. The polymorph observed assumes the simple cubic structure (sc16) initially reported for GaAs at high pressures. Microdiffraction mapping showed variable grain sizes of the synthesized phase, with the largest grains located in the middle of the heated spot. Structural refinements were performed on selected grains. The structure predicted based on first-principles calculations is in close agreement with the experiments. The two Ga–P bonds show similar lengths in sc16-GaP; however, the bond angles differ, resulting in a distorted tetrahedral coordination geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hot Hydride Superconductivity Above 550 K

The search for room temperature superconductivity has accelerated in the last few years driven by experimentally accessible theoretical predictions that indicated alloying dense hydrogen with other elements could produce conventional superconductivity at high temperatures and pressures. These predictions helped inform the synthesis of simple binary hydrides that culminated in the discovery of the superhydride LaH 10 with a superconducting transition temperature T c of 260 K at 180 GPa. We have now successfully synthesized a metallic La-based superhydride with an initial T c of 294 K. When subjected to subsequent thermal excursions that promoted a chemical reaction to a higher order system, the Tc onset was driven irreversibly to 556 K. X-ray characterization confirmed the formation of a distorted LaH 10 based backbone that suggests the formation of ternary or quaternary compounds with substitution at the La and/or H sites. The results provide evidence for hot superconductivity, aligning with recent predictions for higher order hydrides under pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental thermal equation of state of B 2–KCl

The alkali halides are often used as optically-transparent pressure-transmitting media and thermal insulators in laser-heated diamond anvil cell experiments. High P-T equations of state for these materials would allow them to be used simultaneously as sensitive in situ pressure markers, making sample preparation and data analysis simpler. KCl is especially useful for this application because its high melting point, crystallographic simplicity, and low electron density are ideal for use in high-temperature X-ray diffraction experiments. However, the high-temperature static equation of state data for this material is limited in pressure to 8 GPa. As experiments routinely exceed 100 GPa in pressure and thousands of Kelvin, it is necessary for the equation of state of KCl to be determined experimentally at these conditions if it is to be used as an equation of state calibrant in the future. This work combines new high-pressure, high-temperature data of the B2 phase of KCl (up to 167 GPa and 2400 K) with the previously published room-temperature data of Dewaele et al. (2012) to produce a Mie-Gruneisen-Debye thermal equation of state for this material. The room temperature equation of state parameters are similar to those reported previously: V 0 = 32.0(3) cm 3 /mole, K 0 = 24(1) GPa and $K$$^{'}_{0}$ = 4.56(5). The thermal parameters, 0 and q, are 2.9(4) and 1.0(1), respectively. While a q of 1 is expected, the 0 is higher than expected from previous calculations, lower pressure experimental data, and the available shockwave data. Here, previously-reported equations of state underestimate the pressure of KCl at high temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The ultrahigh pressure stability of silver: An experimental and theoretical study

We measured the atomic volume of Ag in a toroidal diamond anvil cell to a maximum pressure of 416 GPa and calculated the atomic volume and elastic constants of Ag up to 750 and 460 GPa, respectively. Our density functional theory calculations at 0 K utilize an all-electron fully relativistic method and agree well with our volume measurements, particularly at pressures above ~75 GPa. In this work, we corrected our experimental results for non-hydrostaticity using a line shift analysis, and the resulting Vinet equation of state (EOS) parameters are reported. We find that the uniaxial stress sustained by Ag increases linearly up to 4.5 GPa at a pressure of 416 GPa. Our experimental results indicate that the fcc structure of Ag remains stable to at least 416 GPa at room temperature. Our theoretical results show that C44 increases as pressure increases and reaches a maximum at ~100 GPa above which it begins to decrease, a sign that the fcc structure of Ag is becoming unstable, and at V/V 0 = 0.30, the bcc structure is lower in energy than fcc.

36 MATERIALS SCIENCE↗