At least 19 records

Performance evaluation of pulse shape discrimination capable organic scintillators for space applications

Scintillators with pulse-shape discrimination (PSD) capability are of great interest to many fields in the scientific community. The ability to discern a gamma ray from a neutron using PSD varies between different types of scintillator materials and dopants. Here a new generation of organic scintillator materials with PSD capability were studied to determine their radiation hardness to neutron and gamma-ray radiation. The PSD capability, average pulse shapes, and light output of four types of organic scintillator were characterized before and after neutron and gamma-ray irradiation. The main goal of this investigation is to study the effects of long-term irradiation that may be experienced in space applications on the light output and particle discriminating capabilities of each material. EJ-270, EJ-276, organic glass, and Stilbene were tested. Damage due to neutron irradiation (displacement damage) was not observed in any of the scintillators up to 2.56 x 10 11 n/cm 2 , except for Stilbene which showed a small (12%) decrease in light output. All scintillators presented some light output reduction after gamma-ray irradiation (total ionizing dose), with reductions of 17% (EJ-276 and OGS), 32% (EJ-270), and 42% (Stilbene) observed immediately after 100 kRad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Derived Neutron Data User Guide, V1.0

The purpose of this document is to provide a brief overview of the Mars Odyssey Improved Derived Neutron Data (IDND) archive. This document is designed to instruct the user on how to find and access the IDND data in order to make basic plots and analyses. It does not explain how to navigate the PDS, nor does it explain how to do high level processing of the data.

47 OTHER INSTRUMENTATION↗

Exploring Gamma-Ray and Neutron Spectroscopy Missions to Mars Caves [Slides]

In this work, we investigate the sensitivity of active neutron detector systems in Mars caves using MCNP6 to model neutron transport in different cave geometries, compositions, and detectors to determine if active neutron measurements can be used to identify the hydration of cave walls vs floor vs ceilings, and to perform a concept study for potential future Mars cave missions in search of hydration and habitable regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Small Penetrator Instrument Concept for the Advancement of Lunar Surface Science

Fundamental scientific objectives concerning the surface and subsurface material and dynamics of the Moon are the drivers for the use and advancement of penetrators, which emplace a suite of scientific instruments by impact into a planetary surface, typically at velocities of dozens to hundreds of meters per second. Small lunar penetrators are poised to become a valuable new tool for lunar science and exploration during the next decade. These low-cost ballistic probes can be deployed in large numbers from orbit, or from descending robotic or crewed vehicles, in order to explore and characterize the diversity of extreme lunar shallow subsurface environments. In this paper, we describe the general overview of penetrator objectives, potential instrumentation, and how these would benefit the advancement of lunar science at various extreme environments.

47 OTHER INSTRUMENTATION↗

Nuclear Spectroscopy for the Exploration of Mars and Beyond

Nuclear spectroscopy will continue to play a critical role in planetary exploration in the next decade, including searching for habitable environments and biosignatures, identifying ideal targets for in-situ resource utilization, and continuing its track record in understanding planetary evolution. Nuclear spectroscopy is the only technique that provides bulk geochemical abundance at depth, at a range of spatial scales depending on platform.

79 ASTRONOMY AND ASTROPHYSICS↗

Proton irradiation damage and annealing effects in ON Semiconductor J-series silicon photomultipliers

Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However, the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. As such, to study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of 1.68 × 10 9 , 1.73 × 10 10 , 6.91 × 10 10 , and 1.73 × 10 11 protons cm –2 , and their corresponding estimated doses of 0.15, 1.55, 6.19, and 15.5 kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Compact readout of large CLYC scintillators with silicon photomultipler arrays

Compact readout of a large (5 x 5 x 5 cm 3) CLYC scintillator was demonstrated with a 8 x 8 array of 6mm silicon photomultipliers (SiPMs, specifically, a SensL ArrayJ-60035-64P) and an optimized amplification and summing circuit. Read out by the SiPM array, the crystal yielded an energy resolution of 5.5% at 662 keV and a figure of merit of 3.5, equivalent to the performance achieved with a 3-inch Hamamatsu R6233-100 PMT. To reduce channel count and avoid individual amplification of each SiPM in the array, the standard outputs of 16 SiPMs were passively summed then amplified. A current feedback amplifier was used for each channel to provide the required fast response time. The four amplified channels were then passively summed resulting in a single signal channel. A custom laboratory setup, based on the PSD8C ASIC, was used to capture the output and provide time-gated integration for PSD computation. We conclude the compact volume, low bias voltage, and reduced mass of the SiPM array readout are desirable for space and national security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of proton-induced radiation damage on CLYC and CLLBC performance

Cerium-doped Cs 2 LiYCl 6 (CLYC) and Cs 2 LiLaBr x Cl 6-x (CLLBC) are scintillators in the elpasolite family that are attractive options for resource-constrained applications due to their ability to detect both gamma rays and neutrons within a single volume. Space-based detectors are one such application, however, the radiation environment in space can over time damage the crystal structure of the elpasolites, leading to degraded performance. We have exposed 4 samples each of CLYC and CLLBC to 800 MeV protons at the Los Alamos Neutron Science Center. The samples were irradiated with a total number of protons of 1.3 x 10 9 , 1.3 x 10 10 , 5.2 x 10 10 , and 1.3 x 10 11 , corresponding to estimated doses of 0.14, 1.46, 5.82, and 14.6 kRad, respectively on the CLYC samples and 0.14, 1.38, 5.52, and 13.8 kRad, respectively on the CLLBC samples. Here, we report the impact these radiation doses have on the light output, activation, gamma-ray energy resolution, pulse shapes, and pulse-shape discrimination figure of merit for CLYC and CLLBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Gamma Signature Accounting for Field Line Transport of Debris Ions after a Nuclear Explosion

Delayed gammas (DGs) are produced by the decay of radioactive fission fragments after a nuclear explosion. Currently, the time and energy profile of the delayed gamma signal is propagated in DIORAMA to the GEO satellite sensors by assuming a point source at the burst location for the production of the delayed gammas. However, in reality the production of delayed gammas is spread over some spatial extent. First, the debris ions are confined within an expanding region by the magnetic field and/or surrounding plasma. This expanding confinement bubble eventually collapses, at which point the debris ions can be trapped on magnetic field lines and transported away from the original burst location. In this work the effects of debris ion transport on the associated time profile of delayed gammas at a GEO satellite is presented. The first step was the development of the Delayed Gamma Source Model (DGSM), which is based on the analytical Electron Source Model (ESM) code developed at LANL that models the spatial distribution of energetic electrons produced after a high-altitude nuclear explosion (HANE) for use as a source term in LANL artificial belt diffusion code. This model creates a spatial grid in latitude, longitude, and altitude of the distribution of radioactive debris ions. The output of this code is combined with a separate analysis code also described, which produces the DG time profile signature at a GEO sensor faceplate when accounting for the spatial spread of delayed gamma production during field line transport. Some simple case studies are presented to show how the DG signature at GEO calculated with this higher-fidelity model and a simple point-source model, as is currently assumed in DIORAMA, compare.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New and Extended Data Processing of Mars Odyssey Neutron Spectrometer Data

The Los Alamos National Laboratory designed and built Mars Odyssey Neutron Spectrometer (MONS) has been operating and collecting data from February 2002 to the present. MONS measures the neutron leakage albedo from galactic cosmic ray bombardment of Mars. These signals can indicate the presence of near-surface water deposits on Mars, and can also be used to study properties of the seasonal polar CO 2 ice caps. This work outlines a new analysis of the MONS data that results in new and extended time-series maps of MONS thermal and epithermal neutron data. The new data are compared to previous publications on the MONS instrument. We then present preliminary results studying the inter-annual variability in the polar regions of Mars based on 8 Mars-Years of MONS data from the new dataset.

79 ASTRONOMY AND ASTROPHYSICS↗