dCache integration with CERN Tape Archive
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Meyer, S..
Explore the source record for details and available documents.
The United States biofuel mandate might be the largest operating program to reduce greenhouse gas (GHG) emissions. Our paper uses regulatory information about abatement and compliance cost estimates to measure the greenhouse gas abatement cost curve of the mandate. Historical compliance costs per unit of biofuel appear readily available, yet findings here show that using these data along with observed biofuel quantities biases biofuel mandate abatement cost estimates upward. Unbiased estimation requires that related biofuel mandate costs and emissions are estimated along with associated market effects, including on fuel use, using an economic model. Moreover, this approach relates greenhouse gas abatement to the implications for crop prices and land use, taking account of interactions within the crop sector. Results show that the United States biofuel mandate causes up to 20 million metric tons of carbon dioxide equivalent abatement for compliance costs that are equivalent to carbon prices ranging up to $20 per ton, with a large part coming from reductions in petroleum product use as the mandate encourages substitution to biofuels. Abatement costs are reduced if ethanol is made at new facilities with fewer emissions or if petroleum output expansion causes greater emissions than the historical average. Results also indicate that GHG abatement via the mandate is initially costly due to the nature of biofuel demand, there can be a trade-off between corn price increase and GHG reduction, and the increase in total area planted to crops in the U.S. is less important than the reallocation of land among crops.
A new ultra-low temperature experiment including a superconducting vector magnet has been developed for soft x-ray absorption spectroscopy experiments at third generation synchrotron light sources. The sample is cooled below 50 mK by a cryogen free {sup 3}He-{sup 4}He dilution refrigerator. At the same time, magnetic fields of up to ±7 T in the horizontal direction and ±0.5 T in the vertical direction can be applied by a superconducting vector magnet. The setup allows to study ex situ and in situ prepared samples, offered by an attached UHV preparation chamber with load lock. The transfer of the prepared samples between the preparation section and the dilution refrigerator is carried out under cryogenic temperatures. First commissioning studies have been carried out at the Variable Polarization XUV Beamline P04 at PETRA III and the influence of the incident photon beam to the sample temperature has been studied.
High-energy e{sup –} and π{sup –} were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5–300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172–345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter’s magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.
Explore the source record for details and available documents.
We present the list of point sources found in the WMAP 5-year maps. The technique used in the first-year and three-year analysis now finds 390 point sources, and the five-year source catalog is complete for regions of the sky away from the galactic plane to a 2 Jy limit, with SNR greater than 4.7 in all bands in the least covered parts of the sky. The noise at high frequencies is still mainly radiometer noise, but at low frequencies the CMB anisotropy is the largest uncertainty. A separate search of CMB-free V-W maps finds 99 sources of which all but one can be identified with known radio sources. The sources seen by WMAP are not strongly polarized. Many of the WMAP sources show significant variability from year to year, with more than a 2:l range between the minimum and maximum fluxes.
This project is divided into four main tasks: cell manufacture, acceptance, and lot certification of cells, performance testing of cells, and abuse testing of cells. Lithium/bromine chloride in thionyl chloride (Li/BCX) 149 DD cells (PN 3B2085-XA) were built according to the provisions of Electrochem Industries Quality Plan 17096. Acceptance and lot certification testing was performed according to NASA JSC Document EP5-83-025, Revision B. Acceptance testing included open circuit and load voltage check, visual examination, size and weight measurements, and high temperature exposure. Lot certification tests were performed for capacity performance and for performance under conditions of thermal and electrical abuse. These tests included 149 C exposure, capacity discharge, fuse check, high temperature exposure, high rate discharge, short circuit, vibration, and overdischarge testing. A quantity of 200 cells was delivered to Johnson Space Center for life test evaluation. A parametric evaluation of the capacity discharge of Li/BCX DD cells was performed over a variety of temperatures and discharge rates. This testing served to map the performance capability of the cell. Tests were also performed over a variety of electrical and thermal abuse conditions. Abuse tests included short circuit, charging, overdischarge, high temperature exposure, shock, and vibration.
Explore the source record for details and available documents.
A large-scale Monte Carlo calculation is presented of the deconfining phase-transition temperature in lattice quantum chromodynamics without fermions. By using the Wilson action, it is found that the transition temperature as a function of the lattice coupling g is consistent with scaling behavior dictated by the perturbative beta function for 6/g-squared greater than 6.15.
A Monte Carlo calculation of the quark-liberating phase transition in lattice quantum chromodynamics is presented. The transition temperature as a function of the lattice coupling g does not scale according to the perturbative beta function for 6/g-squared less than 6.1. Finite-size scaling is used in analyzing the properties of the lattice system near the transition point.
Two versions of a Nasvytis multiroller traction drive were tested in liquid oxygen for possible application as cryogenic boost pump speed reduction drives for advanced hydrogen-oxygen rocket engines. The roller drive, with a 10.8:1 reduction ratio, was successfully run at up to 70,000 rpm input speed and up to 14.9 kW (20 hp) input power level. Three drive assemblies were tested for a total of about three hours of which approximately one hour was at nominal full speed and full power conditions. Peak efficiency of 60 percent was determined. There was no evidence of slippage between rollers for any of the conditions tested. The ball drive, a version using balls instead of one row of rollers, and having a 3.25:1 reduction ratio, failed to perform satisfactorily.
Explore the source record for details and available documents.
FORTRAN program for computing stellar opacity from absorption spectra, electron scattering, and electron conduction data