Search NASA⌕ Search

Engineering topics

Miceli, Antonino

Publications and source records attributed to Miceli, Antonino.

At least 19 records

Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

Guruswamy, Tejas (ORCID:0000000241656765)↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Direct detection system for full-field nanoscale X-ray diffraction-contrast imaging

Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.

47 OTHER INSTRUMENTATION↗

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

Resonant X-ray excitation of the nuclear clock isomer 45 Sc

Resonant oscillators with stable frequencies and large quality factors help us to keep track of time with high precision. Examples range from quartz crystal oscillators in wristwatches to atomic oscillators in atomic clocks, which are, at present, our most precise time measurement devices. The search for more stable and convenient reference oscillators is continuing. Nuclear oscillators are better than atomic oscillators because of their naturally higher quality factors and higher resilience against external perturbations. One of the most promising cases is an ultra-narrow nuclear resonance transition in 45 Sc between the ground state and the 12.4-keV isomeric state with a long lifetime of 0.47 s (ref. 10 ). The scientific potential of 45 Sc was realized long ago, but applications require 45 Sc resonant excitation, which in turn requires accelerator-driven, high-brightness X-ray sources that have become available only recently. Here we report on resonant X-ray excitation of the 45 Sc isomeric state by irradiation of Sc-metal foil with 12.4-keV photon pulses from a state-of-the-art X-ray free-electron laser and subsequent detection of nuclear decay products. Simultaneously, the transition energy was determined as ${\mathrm{12,389.59}}_{+0.12\left({\rm{syst}}\right)}^{\pm 0.15\left({\rm{stat}}\right)}\,{\rm{eV}}$ with an uncertainty that is two orders of magnitude smaller than the previously known values. These advancements enable the application of this isomer in extreme metrology, nuclear clock technology, ultra-high-precision spectroscopy and similar applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Digital encoding algorithm for pixelated detectors

A detector for imaging and efficiently digitizing a spatial distribution of photon flux includes pixel circuits that compressively encode pixel values generated by integrated analog to digital converters (ADCs). On-pixel digital compression circuits (DCCs) implement compression to increase continuous frame rate by reducing the number of bits per pixel while keeping quantization error below Poisson noise. Several mapping algorithms for photon-counting and charge-integrating detectors and compact digital logic implementations are presented.

Hammer, Michael P.↗

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Perovskite CsPbBr 3 Single-Crystal Detector Operating at 10 10 Photons s -1 mm -2 for Ultra-High Flux X-ray Detection

Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr 3 single-crystal detector capable of operating at X-ray fluxes of up to 10 10 photons s -1 mm -2 with beam area ≤ 0.25 mm 2 at 58.61 keV for current-mode X-ray detection is reported. The spectrometer-grade melt-grown CsPbBr 3 detectors show a gamma-ray energy resolution of ~7.5% at 122 keV for 57 Co and dark current as low as 4.3 nA (0.5 nA mm -2 ) at a reverse bias voltage of 200 V (118 V mm -1 ). The detector is tested at X-ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm -1 ). Under a sufficiently high bias voltage and within several hundreds of seconds X-ray exposure, good photocurrent linearity (goodness of fit R 2 > 0.99) and reproducibility are obtained up to a flux of ≈10 10 photons s -1 mm -2 at beam area 0.25 mm 2 with Lower Limit of Detection of ≈10 5 photons s -1 mm -2 and Charge Collection Efficiency of ≈100% for 58.61 keV X-rays. Therefore, wide application of CsPbBr 3 detectors in high-flux X-ray detection is anticipated.

36 MATERIALS SCIENCE↗

Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers

Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.

Bismuth↗

2022 AI Testbed Expeditions Report

By exploiting the coherent properties of a light source, coherent diffraction imaging (CDI) is able to obtain the sample image at a nanoscale resolution using the measured diffraction pattern. Bragg Coherent Diffraction Imaging (BCDI) has become valuable for recovering the displacement and strain field of crystals, providing a valuable tool in material science and solid-state physics. X-ray ptychography is another emerging CDI technique that can produce a high-resolution image of the extended sample and has become popular in many research areas (e.g., materials science, biology, electronics, and optics characterization). CDI including BCDI and ptychography has become an established technique in Synchrotron Facilities including the Advanced Photon Source (APS) and will greatly benefit from the 100x coherent flux increase of the upcoming APS Upgrade (APSU). The current image formation process in CDI employs iterative phase retrieval algorithms, which is a time-consuming and computationally expensive process. Especially after APSU, the traditional iterative methods will not be able to match the experimental data acquisition speed. We employ deep learning (DL) approach to replace the iterative approaches, therefore allowing hundreds of times faster recovery of the object. We developed AutoPhaseNN, a DL-based approach which learns to solve the inverse problem without labeled data. Taking 3D BCDI as a representative technique, AutoPhaseNN has been demonstrated to be one hundred times faster than traditional iterative phase retrieval methods while providing comparable image quality. The current network is trained with 64 x 64 x 64 data size, to achieve higher resolution imaging, we will need to scale the network to input and train/infer 3D arrays of size 256 x 256 x 256 (today) and of size 2560x2560x2560 (APSU). However, the scalability of the network is restricted due to the memory-intensive training process. To perform the training for a 256 x 256 x 256 data size, the required memory exceeds the capacity of the current machine. In this project, we explore using Sambanova system to train the network for the direct data inversion for CDI.

36 MATERIALS SCIENCE↗

A lightweight, user-configurable detector ASIC digital architecture with on-chip data compression for MHz X-ray coherent diffraction imaging

Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionalities from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable detector ASIC digital architecture with on-chip compression which can be implemented in 130 nm technologies in a reasonable area on the ASIC periphery. In addition, we present a design to efficiently handle the variable data from the stream of parallel compressors. The architecture includes user-selectable lossy and lossless compression blocks. The impact of lossy compression algorithms is evaluated on simulated and experimental X-ray ptychography datasets. This architecture is a practical approach to increase pixel detector frame rates towards the continuous 1 MHz regime for not only coherent imaging techniques such as ptychography, but also for other diffraction techniques at X-ray light sources.

47 OTHER INSTRUMENTATION↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗