Search NASA⌕ Search

Engineering topics

Mihalczo, John T.

Publications and source records attributed to Mihalczo, John T..

HEU Metal Delayed Critical Experiments with 10 to 19 Inch Thick Graphite Reflectors

Approximately 100 graphite-reflected highly enriched uranium (HEU, 93.14 wt % 235 U) metal annular and cylindrical critical experiments were performed in the early 1960s at the Oak Ridge Critical Experiments Facility (ORCEF). This report presents details from experiment logbooks, experimental data sheets and the author's memory for 44 HEU metal (93.14 wt % 235 U) critical assemblies with graphite reflectors varying from 10 to 19 in. thick, outside diameters varying from 7 to 15 in., inside diameters varying from 7 to 13 in. and critical HEU metal masses varying from 20.4 to 69.0 kg. The data from the 44 experiments described in this report are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Evaluation Program (ICSBEP) once the uncertainty analysis on the measured k eff is completed. Based on previous ICSBEP benchmarks with this HEU metal at ORCEF, the uncertainties in the measured k eff are expected to be as low as ±0.0004. Preparation of this report is part of an effort at Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented series of critical and subcritical experiments enumerated in Critical and Subcritical NEA Benchmark Possibilities for Measurements at ORCEF and Other US DOE Facilities (Mihalzo, ORNL/TM-2019/1188, 2019) and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities. More than 500 operational days of critical facility time were used, not including setup and dismantlement time. This documentation for a part of one series of graphite reflected highly enriched uranium metal critical experiments, that used 50 operational days of ORCEF time, was performed using funding received from the DOE Office of Nuclear Energy’s Nuclear Energy University Programs at the University of Tennessee Nuclear Engineering Department. This documentation was also supported by the Nuclear Criticality, Radiation Transport, and Safety programs at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical Highly Enriched Uranium Metal Cylinders with Thin Graphite Top and Bottom Reflectors

Nine 7, 11, and 15 in. diam highly enriched uranium (HEU, 93.15 wt % 235 U) metal cylinders were assembled on the vertical assembly machine in the Oak Ridge Critical Experiments Facility (ORCEF) and had 1, 2, or 3 in. thick HLM graphite reflectors on the top and bottom. The experiments, which were performed between April 3, 1970, and February 18, 1971, used 23 operational days at ORCEF. Before those experiments were carried out, unreflected and unmoderated, graphite- and polyethylene-reflected, and polyethylene-moderated HEU metal cylinders had been assembled to obtain delayed criticality at ORCEF in the 1960s and reported by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) at the Nuclear Energy Agency (NEA)*. The data from the nine critical experiments are acceptable for use as criticality safety benchmark experiments for the NEA’s ICSBEP once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with HEU metal at ORCEF, the uncertainties in k eff are expected to be as low as ±0.0004.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Addendum to ICSBEP Logbooks 12r, 13r, 14r and 15r for Polyethylene and Graphite Reflected HEU Metal Critical Experiments

This report documents the experimenters’ data sheets that were recently (2023) discovered for critical experiments with highly enriched uranium metal with polyethylene and graphite reflectors. These data sheets were produced at the time of the measurements, when the dimensional inspection reports for the polyethylene and graphite were available. However, at this writing, those inspection reports are not available but may be in unmarked storage for the Y-12 National Security Complex. However, the data sheets presented herein contain sketches of the experimental configurations and other additional information that is not in the logbooks, such as dimensions and masses of the graphite measurements. This report reproduces the experimental data sheets that complement the logbooks. Some of the data on these sheets and the logbooks can be used to infer the dimensions and masses that are not documented. Some obvious mistakes in the logbook and data sheets have been corrected. In the reproduced data sheets, some of the information is not clearly visible: some information, such as average values, can be obtained from other data in the sheets or logbook. This report should be sent to the International Criticality Safety Benchmark Program at Idaho National Laboratory to complement the existing Oak Ridge Critical Facility logbooks there.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Subcritical Californium Source Drive Noise Analysis Measurements With Unreflected Uranium (93.15) Hydride

On July 6, 1989, subcritical californium source-driven noise analysis (CSDNA) measurements were performed with bare uranium hydride cylindrical assemblies at the Los Alamos National Laboratory Critical Experiments Facility in KIVA 1. Three configurations of ~7.5 cm radius-enriched (93.15 wt. % 235 U) uranium hydride with a density of ~10 g/cm 3 cylinders were assembled with uranium hydride heights of ~11, ~14, and ~16 cm. The uranium hydride (~2 and ~3 cm high) was in thin-welded stainless steel cans. The neutron multiplication factors obtained on-line from the measured ratios of spectral densities were 0.942 ± 0.002, 0.917 ± 0.003, and 0.867 ± 0.004 for uranium hydride heights of ~16, ~14, and ~11 cm., respectively. Neutron multiplication factors for these three configurations calculated by Los Alamos National Laboratory Monte Carlo methods were 0.952 ± 0.005, 0.922 ± 0.005, and 0.860 ± 0.005, all of which are in good agreement with the measurements. The break frequency noise analysis data could be fitted to obtain the prompt neutron decay constant at all subcritical states. Some data presented in this report are from notes that are not in the logbooks. A discussion of the two different point kinetics theories of the measurements that illustrated the deficiencies of the rigorous theory at low neutron multiplication factors (k eff < 0.80) is given in an Appendix. These measurements may be the only configuration of unreflected, highly enriched uranium hydride configuration assembled. The presence of hydrogen diluted the uranium density, decreasing the reactivity, but this is offset by slowing down the neutron energy to the energy ranges of higher-fission cross sections. Extrapolations to delayed critical indicate that adding one more 3 cm can and one more 2 cm can would result in the unreflected cylindrical system being slightly above critical with a critical mass of ~37 kg, which is considerably less than the critical mass of an unreflected and unmoderated highly enriched uranium metal sphere. An unreflected, highly enriched uranium hydride sphere would have a critical mass less than 37 kg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical and Subcritical Californium Source Driven Noise Analysis Experiments with Fresh PWR Fuels Pins

These experiments were performed in 1983 between August 1 and September 16 and used 35 operational days of critical facility time at the Babcock & Wilcox critical facility in Lynchburg, Va. These measurements were to assess the capability of the Cf source driven noise analysis method to measure the subcriticality of light water reactor fresh fuel configurations. This report documents the experiments of 1983 that were not reported at that time. These measurement with 2.459 wt. % 235 U enriched uranium oxide fresh fuel pins started at the delayed critical configuration of the fully assembled pressurized water reactor (PWR) core configuration with 1511 parts per million (ppm) natural boron (19.8 wt. % 10 B) in the water. This was a cylindrical configuration of 4961 fuel pins. After the initial measurements at delayed criticality, subcritical measurements by the Cf source driven noise analysis method were performed in which the number of detectors and Cf source locations were varied. Additional boron was added to the water moderator and reflector to reduce the neutron multiplication factor, with resulting boron concentrations of 1561, 1613, 1765, 1880, 2104, 2384, 2975, 3606, and 4303 ppm. After the completion of these measurements the increased, the boron concentration was returned to that at delayed critical (1511 ppm) and the reactivity was decreased by reducing the number of fuel pins in steps to 3713, 2553, 1281, 749, and 333 fuel pins and then to that (289) of a s ingle square 17 x 17 pin array, corresponding to a single PW fuel element. For all measurement that started at delayed criticality and then reduced the neutron multiplication factor to various subcritical states, inverse kinetics rod drop measurements at the higher reactivities were also performed but not reported here. At all subcritical states the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. Some data presented in this report are from notes not in the logbook. The purpose of this report is to document the experimental information for the measurements performed so that a later date someone could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (INCSBEP) or Nuclear Energy Agency (NEA) benchmark. The data from these measurements is available from the Laboratory Records Department of Oak Ridge National Laboratory and the logbook is available from INCSBEP at Idaho National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders Without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with three unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in August and September 1963 and described in logbook E 20 associated with experiments in the East cell of ORCEF. The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-1/8to 2.00 inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these six experiments described are judged to be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in measured keff could be as low as ± 0.0002.

36 MATERIALS SCIENCE↗

Two Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with two unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in May to Aug 1963 and described in logbook E-19 and E -20 associated with experiments in the East cell of ORCEF. Measurements were also performed in April and May of 1965 and described in logbooks E-22 and E-23 The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235 U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-5/8 to 3.0-inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these 12 experiments described would be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in k eff could be as low as ± 0.0002.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data from Rossi-α and Pulsed Neutron Prompt Neutron Time Decay Measurements at the Oak Ridge Critical Experiments Facility

This report briefly describes the prompt neutron decay measurements by the Rossi-α and pulsed neutron methods performed at the Oak Ridge Critical Experiments Facility. It briefly describes the measurement equipment, the type of data, and how to access the actual data from the Laboratory Records Department at Oak Ridge National Laboratory and the International Nuclear Criticality Safety Benchmark Evaluation Program at Idaho National Laboratory. Most of the data was acquired between 1960 and 1975 with weapons-grade enriched uranium metal assemblies. It also includes measurement of these types performed at Los Alamos National Laboratory by Oak Ridge National Laboratory with the JEZEBEL and FLATTOP criticality assemblies and other plutonium metal parts. The purpose of this report is to support future mining of the data for publication of additional information that can be used to verify calculational methods and nuclear cross sections. Present calculational methods can be used to directly calculate the measured data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗