Search NASA⌕ Search

Engineering topics

Mihara, Tatehiro

Publications and source records attributed to Mihara, Tatehiro.

X-Ray Polarimetry with the Polarization Spectroscopic Telescope Array (PolSTAR)

This paper describes the Polarization Spectroscopic Telescope Array (PolSTAR), a mission proposed to NASA's 2014 Small Explorer (SMEX) announcement of opportunity. PolSTAR measures the linear polarization of 3-50 keV (requirement; goal: 2.5-70 keV) X-rays probing the behavior of matter, radiation and the very fabric of spacetime under the extreme conditions close to the event horizons of black holes, as well as in and around magnetars and neutron stars. The PolSTAR design is based on the technology developed for the Nuclear Spectroscopic Telescope Array (NuSTAR) mission launched in June 2012. In particular, it uses the same X-ray optics, extendable telescope boom, optical bench, and CdZnTe detectors as NuSTAR. The mission has the sensitivity to measure approx. 1% linear polarization fractions for X-ray sources with fluxes down to approx. 5 mCrab. This paper describes the PolSTAR design as well as the science drivers and the potential science return.

Krawczynski, Henric S.↗

Broad-Band Spectroscopy of Hercules X-1 with Suzaku

Hercules X-1 was observed with Suzaku in the main-on state from 2005 to 2010. The 0.4- 100 keV wide-band spectra obtained in four observations showed a broad hump around 4-9 keV in addition to narrow Fe lines at 6.4 and 6.7 keV. The hump was seen in all the four observations regardless of the selection of the continuum models. Thus it is considered a stable and intrinsic spectral feature in Her X-1. The broad hump lacked a sharp structure like an absorption edge. Thus it was represented by two different spectral models: an ionized partial covering or an additional broad line at 6.5 keV. The former required a persistently existing ionized absorber, whose origin was unclear. In the latter case, the Gaussian fitting of the 6.5-keV line needs a large width of sigma = 1.0-1.5 keV and a large equivalent width of 400-900 eV. If the broad line originates from Fe fluorescence of accreting matter, its large width may be explained by the Doppler broadening in the accretion flow. However, the large equivalent width may be inconsistent with a simple accretion geometry.

X-rays: stars↗

Broad-band Spectroscopy of Hercules X-1 with Suzaku

Hercules X-1 was observed with Suzaku in the main-on state from 2005 to 2010. The 0.4–100 keV wide-band spectra obtained in four observations showed a broad hump around 4–9 keV in addition to narrow Fe lines at 6.4 and 6.7 keV. The hump was seen in all the four observations regardless of the selection of the continuum models. Thus it is considered a stable and intrinsic spectral feature in Her X-1. The broad hump lacked a sharp structure like an absorption edge. Thus it was represented by two different spectral models: an ionized partial covering or an additional broad line at 6.5 keV. The former required a persistently existing ionized absorber, whose origin was unclear. In the latter case, the Gaussian fitting of the 6.5-keV line needs a large width of σ = 1.0–1.5 keV and a large equivalent width of 400–900 eV. If the broad line originates from Fe fluorescence of accreting matter, its large width may be explained by the Doppler broadening in the accretion flow. However, the large equivalent width may be inconsistent with a simple accretion geometry.

Asami, Fumi↗

The Astro-E/XRS Calibration Program and Results

XRS is the microcalorimeter X-ray detector aboard the US-Japanese ASTRO-E observatory, which is scheduled to be launched in early 2000. XRS is a high resolution spectrometer- with less than 9 eV resolution at 3 keV and better than 14 eV resolution over its bandpass ranging from about 0.3 keV to 15 keV. Here we present the results of our first calibration of the XRS instrument. We describe the methods used to extract detailed information about the detection efficiency and spectral redistribution of the instrument. We also present comparisons of simulations and real data to test our detector models.

Gendreau, Keith C.↗

The Astro-E High Resolution X-Ray Spectrometer

The Astro-E High Resolution X-ray Spectrometer (XRS) was developed jointly by the NASA/Goddard Space Flight Center and the Institute of Space and Astronautical Science in Japan. The instrument is based on a new approach to spectroscopy, the X-ray microcalorimeter. This device senses the energies of individual X-ray photons as heat with extreme precision. A 32 channel array of microcalorimeters is being employed, each with an energy resolution of about 12 eV at 6 keV (the Fe-K region). This will provide spectral resolving power 10 times higher than any other non-dispersive X-ray spectrometer. The instrument incorporates a three stage cooling system capable of operating the array at 60 mK for about two years in orbit. The array sits at the focus of a grazing incidence conical mirror. The quantum efficiency of the microcalorimeters and the reflectivity of the X-ray mirror system combine to give high throughput over the 0.3-12 keV energy band. This new capability will enable the study of a wide range of high-energy astrophysical sources with unprecedented spectral sensitivity. This paper presents the basic design requirements and implementation of the XRS, and also describes the instrument parameters and performance.

Kelley, Richard L.↗

The Astro-E/XRS Calibration Program and Results

XRS is the microcalorimeter X-ray detector aboard the US-Japanese ASTRO-E observatory, which is scheduled to be launched in early 2000. XRS is a high resolution spectrometer- with less than 9 eV resolution at 3 keV and better than 14 eV resolution over its bandpass ranging from about 0.3 keV to 15 keV. Here we present the results of our first calibration of the XRS instrument. We describe the methods used to extract detailed information about the detection efficiency and spectral redistribution of the instrument. We also present comparison of simulations and read data to test our detector models.

Gendreau, Keith C.↗

The Astro -E/XRS Calibration Program and Results

XRS is the microcalorimeter X-ray detector aboard the US-Japanese ASTRO-E observatory, which is scheduled to be launched in early 2000. XRS is a high resolution spectrometer- with less than 9 eV resolution at 3 keV and better than 14 eV resolution over its bandpass ranging from about 0.3 keV to 15 keV. Here we present the results of our first calibration of the XRS instrument. We describe the methods used to extract detailed information about the detection efficiency and spectral redistribution of the instrument. We also present comparisons of simulations and real data to test our detector models

Gendreau, Keith C.↗

ASCA observations of the warm absorber in MCG-6-30-15: The discovery of a change in column density

We report the first X-ray observations of the Seyfert 1 galaxy MCG-6-30-15 obtained at medium spectral resolution. The partially-ionized, 'warm' absorber is resolved and shown to be due to O VII and O VIII. The main absorption edge agrees with that of O VII at the redshift of the galaxy to within 1%. The column density of the absorbing material is greater by a factor of 2 in the first of our two obsevations, which were 3 weeks apart, while the mean flux is slightly lower and the ionization parameter slightly higher. We also discuss the flourescent iron emssion line seen in the source, which is at 6.40 keV. The line is significantly broadened, with a Full Width at Half Maximum (FWHM) of about 0.4 keV.

Fabian, Andrew C.↗

ASCA observation of three bright early-type galaxies: NGC 4472, NGC 4406, and NGC 4636

We report Advanced Satellite for Cosmology and Astrophysics (ASCA) 0.3-10 keV and X-ray observations of three early type galaxies, NGC 4472, NGC 4406, and NGC 4636. The extended mission in these galaxies is well described by thin thermal eimssion from hot gas. The gas temperature is 0.92 +/- 0.02 keV for NGC 4472, 0.79 +/- 0.01 keV for NGC 4406, and 0.73 +/- 0.02 keV for NGC 4636. The metal abundance for NGC 4472, NGC 4406, and NGC 4636 are, under the assumption of solar ratios, 0.63 +/- 0.15, 0.45 +/- 0.10, and 0.38 +/- 0.07, respectively. Detailed analysis has allowed determination of the abundances of oxygen, silicon, sulfur, and iron. The observed abundances are consistent with the solar ratios. For NGC 4472 and NGC 4406 we also determined the mean temperature of the gas producing the Si lines from the ratio of the Si H to He-like lines and find it to be consistent with the continuum temperature. The X-ray temperature is in good agreement with the observed optical velocity dispersion, stellar density profile, and gas density profile. Our data indicates that the supernova rate should be less than one fifth of the nominal rate in early type galaxies. We derive the mass of these systems within fixed angular scales and find that M/L greater than 40, confirming that elliptical galaxies are dark matter dominated at large radii.

Awaki, Hisamitsu↗

The broad band X-ray spectrum of SN 1978k and two other luminous X-ray sources in the spiral galaxy NGC 1313

We present preliminary results of our analysis of the Advanced Satellite for Cosmology and Astrophysics (ASCA) PV phase observation of the nearby spiral galaxy NGC 1313. ASCA cleanly resolves the three previously known luminous sources, one of which is the very luminous supernova, SN 1978k. The spectrum of SN 1978k is described by either a power law with a photon index gamma approximately 2.2 or a thermal model with temperature kT approximately 3.0 keV and abundances Z approximately 0.2 Z(sun). There is no evidence for strong line emission from it or from the other two sources. The spectrum of SN 1978k arises either in shocked gas in extreme departure from ionization equilibrium or from synchrotron processes associated with a newborn pulsar. A second source, near the galactic center, is well-fit by a power-law with a photon index of approximately 1.8. It is possibly an active nucleus-like source, but physically displaced from the optical nucleus of the galaxy. The spectrum of the third source, located 8 kpc south of the nucleus, along with the absence of an optical counterpart, suggests that it is a low mass X-ray binary; but its high X-ray luminosity clouds this interpretation. This observation demonstrates the ability of ASCA to perform effective broad band spectroscopic measurements of sources at a 2-10 keV flux level of 5 x 10(exp -13) erg cm(exp -2) s(exp -1).

Petre, Robert↗

Soft X-ray spectral features in the Seyfert 1 Galaxy NGC4051

We report ASCA observations of NGC 4051 during the PV phase. The time averaged X-ray spectrum is not well fit by a simple power law with an iron K-emission line and shows significant absorption-edge features most probably due to O VII and O VIII and a strong soft excess. This is the first direct measurement of edges in the spectrum of this object and confirms that the X-ray spectrum of NGC 4051 is modified by a 'warm' absorbing gas. The best fit underlying power law index in the 0.4-10 keV band is 1.88. A power law modified by a warm absorber model can partly explain the apparent soft excess and qualitatively fit the SIS spectrum. However, the addition of a black body of kT approx. = 0.1 keV improves the fit considerably. The 90% upper limit on the width of the iron line is 460 eV full width at half maximum (FWHM). Applying the fluorescent iron line model from an accretion disk gives an upper limit of 20 deg for the inclination of the disk.

Mihara, Tatehiro↗