Search NASA⌕ Search

Engineering topics

Miko, David K.

Publications and source records attributed to Miko, David K..

A Practical Assessment of the Effect of Water Interspersed with Plutonium Metal Hemishells - Summary

Operations with fissile materials can be performed safely by complying with any of the listed single-parameter subcritical limits in ANS-8.1. For metallic units, the single-parameter subcritical limits apply to a single piece having no concave surfaces. They may be extended to an assembly of pieces, provided that there is no neutron moderating material interspersed with the pieces. An MCNP6.1 study was undertaken at the Los Alamos National Laboratory (LANL) to investigate the effect that interspersed water has on plutonium-metal hemishells. At LANL, it is common to have more than one hemishell at any given location, which obviously have concave surfaces. The intent of this paper is to present a high-level summary of the effect of having multiple concave shells, interspersed with water, as well as to discuss the methodology we used to determine the Upper Subcritical Limits (USL's) associated with the results. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of Fresh Fuel Rods to Demonstrate Compliance with Criticality Safety Limits

In order to operate TA-66 as a radiological facility with the quantity of nuclear material required to fulfil its mission, a criticality safety evaluation was required. This evaluation defined the control parameters for operations at the facility. The resulting evaluation for TA-66 placed limits on the amount of SNM, as well as other materials such as beryllium. In addition, there is a limit on the number of uranium fuel rods allowed subject to enrichment, outer diameter, and overall length restrictions. The enrichments for the rods to be shipped to TA-66 were documented in LA-UR-13-23581, but the outer diameter and length were not documented. This report provides this information.

42 ENGINEERING↗

An Empirical Method for Determining 234 U Percentage

When isotopic information for uranium is provided, the concentration of 234 U is frequently neglected. Often the isotopic content is given as a percentage of 235 U with the assumption that the remainder consists of 238 U. In certain applications, such as heat output, the concentration of 234 U can be a significant contributing factor. For situations where only the 235 U and 238 U values are given, a simple way to calculate the 234 U component would be beneficial. The approach taken here is empirical. A series of uranium standards with varying enrichments were analyzed. The 234 U and 235 U data were fit using a second order polynomial.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NEN-1 Fuel Rod Imaging Analysis

NEN1 is in possession of a variety of nuclear fuel rods. For verification purposes and to help with criticality safety evaluations, these rods have been measured to determine their pallet diameter. In this paper, the methodology for acquiring the fuel rod pelet diameter is described and the analysis for the pallet diameter is presented.

07 ISOTOPE AND RADIATION SOURCES↗

Confinement Vessel Assay System: Design and Implementation Report

Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC&A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using 252 Cf placed a various locations throughout the measurement system. Measurements were also performed with a 252 Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

36 MATERIALS SCIENCE↗

Confinement Vessel Assay System: Calibration and Certification Report

Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of ≤ 100-g 239 Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

36 MATERIALS SCIENCE↗