Development of X-33/X-34 Aerothermodynamic Data Bases: Lessons Learned and Future Enhancements

A synoptic of programmatic and technical lessons learned in the development of aerothermodynamic data bases for the X-33 and X-34 programs is presented in general terms and from the perspective of the NASA Langley Research Center Aerothermodynamics Branch. The format used is that of the "aerothermodynamic chain," the links of which are personnel, facilities, models/test articles, instrumentation, test techniques, and computational fluid dynamics (CFD). Because the aerodynamic data bases upon which the X-33 and X-34 vehicles will fly are almost exclusively from wind tunnel testing, as opposed to CFD, the primary focus of the lessons learned is on ground-based testing. The period corresponding to the development of X-33 and X-34 aerothermodynamic data bases was challenging, since a number of other such programs (e.g., X-38, X-43) competed for resources at a time of downsizing of personnel, facilities, etc., outsourcing, and role changes as NASA Centers served as subcontractors to industry. The impact of this changing environment is embedded in the lessons learned. From a technical perspective, the relatively long times to design and fabricate metallic force and moment models, delays in delivery of models, and a lack of quality assurance to determine the fidelity of model outer mold lines (OML) prior to wind tunnel testing had a major negative impact on the programs. On the positive side, the application of phosphor thermography to obtain global, quantitative heating distributions on rapidly fabricated ceramic models revolutionized the aerothermodynamic optimization of vehicle OMLs, control surfaces, etc. Vehicle designers were provided with aeroheating information prior to, or in conjunction with, aerodynamic information early in the program, thereby allowing trades to be made with both sets of input; in the past only aerodynamic data were available as input. Programmatically, failure to include transonic aerodynamic wind tunnel tests early in the assessment phase led to delays in the optimization phase, as OMLs required modification to provide adequate transonic aerodynamic performance without sacrificing subsonic and hypersonic performance. Funding schedules for industry, based on technical milestones, also presented challenges to aerothermodynamics seeking optimum flying characteristics across the subsonic to hypersonic speed regimes and minimum aeroheating. This paper is concluded with a brief discussion of enhancements in ground-based testing/CFD capabilities necessary to partially/fully satisfy future requirements.

Miller, C. G.

Development of X-33/X-34 Aerothermodynamic Data Bases: Lessons Learned and Future Enhancements

A synoptic of programmatic and technical lessons learned in the development of aerothermodynamic data bases for the X-33 and X-34 programs is presented in general terms and from the perspective of the NASA Langley Research Center Aerothermodynamics Branch. The format used is that of the aerothermodynamic chain, the links of which are personnel, facilities, models/test articles, instrumentation, test techniques, and computational fluid dynamics (CFD). Because the aerodynamic data bases upon which the X-33 and X-34 vehicles will fly are almost exclusively from wind tunnel testing, as opposed to CFD, the primary focus of the lessons learned is on ground-based testing.

Miller, C. G.

Langley hypersonic aerodynamic/aerothermodynamic testing capabilities - Present and future

The Langley Hypersonic Facilities Complex consists of nine hypersonic, blowdown-to-vacuum wind tunnels that complement one another to provide a range of Mach number from 6 to 22, with Reynolds number from 0.03 to 40 million per foot and, most importantly for blunt configurations, a normal shock density ratio from 4 to 12. Presently, most of these facilities are receiving modifications and upgrades to hardware components and instrumentation to increase their capability, reliability, and productivity. Descriptions and capabilities of these facilities are presented along with measurement techniques routinely used. Future facility plans are discussed, with the focus on an Advanced Hypervelocity Aerophysics Facility being proposed for construction in the mid-1990s.

Miller, C. G.

Heat transfer measurements on biconics at incidence in hypersonic high enthalpy air and nitrogen flows

Heat transfer rate measurements have been obtained at 0, 5, 15, and 21 deg angles-of-attack for a straight biconic scale model of an aeroassisted orbital vehicle proposed for planetary probe missions. Heat-transfer distributions were measured using palladium thin-film resistance gauges deposited on a glass-ceramic substrate. The windward heat transfer correlations were based on equilibrium flow in the shock layer of the model, although the flow may depart from equilibrium in the flow-field.

Gai, S. L.

Measured and predicted heating distributions for biconics at Mach 10

Laminar heating distributions have been measured on a 1.9 percent scale model of a generic aeroassisted vehicle taking the shape of a spherically blunted, 13-deg/7-deg biconic whose forecone section is bent upward (by 7 deg) to furnish self-trim capability at a 20-deg angle-of-attack. The results thus obtained were compared with data gathered for a straight biconic. While no Reynolds number effect on heating was noted on the windward side of the forecone, the opposite was true of the leeward side, where a Reynolds number increase caused circumferential flow separation at lower angles of attack. Generally, windward heating was predicted to within 10 percent with a computer code solving the steady, three-dimensional parabolized Navier-Stokes equations.

Miller, C. G.

Langley hypersonic facilities complex - Description and application

The Langley Hypersonic Facilities Complex (HFC) consists of hypersonic, blowdown wind tunnels developed and put into operation between the late 1950's and early 1970's. These facilities complement one another to presently provide ranges of Mach number from 6 to 22, unit Reynolds number from 0.1 to 15 million per foot, and normal shock density ratio from 4 to 12. Descriptions of these facilities are presented along with the testing techniques routinely used. Examples of the application of the HFC to generate data bases for proposed entry vehicles and for the verification of computer codes are given. Plans to upgrade the facilities to improve flow quality, productivity, capability and reliability are discussed.

Miller, C. G.

Measured and predicted vortex-induced leeward heating on a biconic at Mach 6 and 10

Detailed longitudinal and circumferential heating distributions were measured on a spherically blunted, 13 deg/7 deg biconic at angles of attack from 0 deg to 27 deg. The measurements were made in the Langley 20-inch Mach 6 tunnel and 31-inch Mach 10 tunnel to provide heating distributions at Mach 6 and 10 in air. The free-stream Reynolds number based on model length varied from 0.4 to 4.8 million at Mach 6 and 0.3 to 1.3 million at Mach 10. The basic trends in leeward heating are found to be described by a single parameter, the viscous interaction parameter. A decrease in this parameter results in a decrease in leeward heating for attached flow, an increase in heating for separated flow, and a forward movement of the separation region. The parabolized Navier-Stokes code for laminar flow qualitatively predicted the longitudinal and circumferential heating distributions.

Miller, C. G.

Refinement of an 'alternate' method for measuring heating rates in hypersonic wind tunnels

Recently obtained hypersonic wind tunnel results are presented which resolve the principal uncertainty associated with the use of thin film gages on substrates of the glass ceramic substance designated MACOR.THe uncertainty is with respect to both MACOR's thermal properties and the variation of these properties with temperature. The relatively large influence of shock strength on stagnation point heating at low Reynolds numbers is illustrated.

Miller, C. G.

Stabilizing Crystal Oscillators With Melting Metals

Heat of fusion provides extended period of constant temperature and frequency. Crystal surrounded by metal in spherical container. As outside temperature rises to melting point of metal, metal starts to liquefy; but temperature stays at melting point until no solid metal remains. Potential terrestrial applications include low-power environmental telemetering transmitters and instrumentation transmitters for industrial processes.

Stephens, J. B.

Experimental heating distributions for biconics at incidence in Mach 10 air and comparison to prediction

Heating distributions were measured on a 1.9 percent scale model of a generic, aeroassisted vehicle proposed for missions to a number of planets and also a candidate as a moderate L/D earth orbital transfer vehicle. This vehicle is a spherically blunted, 13 deg/7 deg biconic with the fore-cone bent upward 7 deg to provide self-trim capability; also tested was a straight biconic with the same noise radius and half angles. These measurements were made in the Langley 31-Inch Mach 10 Tunnel at values of the free-stream Reynolds number, based on model length, equal to 0.2 and 0.9 million. The angle of attack, referenced to the aft cone, was varied from 0 to 20 deg. Heating distributions predicted with a parabolized Navier Stokes (PNS) code are compared to measurement over the present range of Reynolds number and angle of attack. Windward heating was predicted to within 10 percent by the PNS code. Leeward heating distributions were predicted qualitatively for both values of Reynolds number, but quantitative agreement was poorer than on the windward side.

Miller, C. G.

Heat-transfer distributions for biconics at incidence in hypersonic-hypervelocity real-gas flows

Laminar heat-transfer distributions were measured on spherically blunted, 13/7 deg straight and bent biconics at freestream velocities from 4.5 to 6.9 km/s and Mach numbers from 6 to 9. The flows were generated in the NASA's Langley Expansion Tube using helium, nitrogen, air, and carbon dioxide; angle of attack, referenced to the axis of the aft cone, was varied from zero to 20 deg. The penalty in windward heating to the fore cone due to the 7-deg nose bend diminished rapidly with increasing angle of attack and was only 10 to 20 percent at the design trim angle of attack of 20 deg. Leeward heating initially decreased, then increased, with increasing angle of attack. Windward heating rates predicted with a computer code that solves the parabolized Navier-Stokes equations were in good agreement with measurements for helium and air. The study used a 1.9-percent scale model of the proposed generic planetary vehicle and is directly applicable to the orbital transfer vehicle, which incorporates a spherically blunted biconic.

Miller, C. G.

Gas-Bearing Crucible for Shot Tower

Device protects molten drops from contamination and distortion. Gas flowing through levitator tube levitates small balls while they melt. Gas heated by filament extending through center of tube. Gas bearing crucible on tube has concave configuration to hold single relatively large ball or many recesses to hold many small balls. By time spheres reach foam, they are cooled sufficiently by radiation to retain their shape.

Youngberg, C. L.

Sphere forming method and apparatus

A system is provided for forming small accurately spherical objects. Preformed largely spherical objects are supported at the opening of a conduit on the update of hot gas emitted from the opening, so the object is in a molten state. The conduit is suddenly jerked away at a downward incline, to allow the molten object to drop in free fall, so that surface tension forms a precise sphere. The conduit portion that has the opening, lies in a moderate vacuum chamber, and the falling sphere passes through the chamber and through a briefly opened valve into a tall drop tower that contains a lower pressure, to allow the sphere to cool without deformation caused by falling through air.

Youngberg, C. L.

Heat-transfer distributions on biconics at incidence in hypersonic-hypervelocity He, N2, air, and CO2 flows

Laminar heat-transfer rates were measured on spherically blunted, 13 degrees/F degrees on-axis and bent biconics (fore cone bent 7 degrees upward relative to aft cone) at hypersonic-hypervelocity flow conditions in the Langley Expansion Tube. Freestream velocities from 4.5 to 6.9 km/sec and Mach numbers from 6 to 9 were generated using helium, nitrogen, air, and carbon dioxide test gases, resulting in normal shock density ratios from 4 to 19. Angle of attack, referenced to the axis of the aft cone, was varied from zero to 20 degrees in 4 degree increments. The effect of nose bend, angle of attack, and real-gas phenomena on heating distributions are presented along with comparisons of measurement to prediction from a code which solves the three-dimensional 'parabolized Navier-Stokes' equations.

Miller, C. G.

Heat-transfer distributions on biconics at incidence in hypersonic-hypervelocity He, N2, air, and CO2 flows

Laminar heat transfer rates were measured on spherically blunted, 13 deg/7 deg on axis and bent biconics (fore cone bent 7 deg upward relative to aft cone) at hypersonic hypervelocity flow conditions in the Langley Expansion Tube. Freestream velocities from 4.5 to 6.9 km/sec and Mach numbers from 6 to 9 were generated using helium, nitrogen, air, and carbon dioxide test gases, resulting in normal shock density ratios from 4 to 19. Angle of attack, referenced to the axis of the aft cone, was varied from 0 to 20 deg in 4 deg increments. The effect of nose bend, angle of attack, and real gas phenomena on heating distributions are presented along with comparisons of measurement to prediction from a code which solves the three dimensional parabolized Navier-Stokes equations.

Miller, C. G.

An experimental investigation of control surface effectiveness and real-gas simulation for biconics

Aerodynamic coefficients, pressure distributions, and oil-flow patterns measured on spherically blunted, 13 degrees/7 degrees on-axis and bent biconics at Mach 6 and 10 in air are compared. Angle of attack, referenced to the axis of the aft cone, was varied from zero to 40 degrees. The effect of deflection of base-mounted flaps on aerodynamic characteristics was examined at Mach 10. Real-gas effects on aerodynamic coefficients, pressure distributions and shock detachment distance were simulated by testing the biconic models in Mach 6 air and Mach 6 CF4 flows. (Density ratio equal to 5.3 for air and 12 for CF4.) The on-axis biconic is stable but cannot be trimmed at angles of attack above zero with the assumed center of gravity and flap configuration. Flaps on the bent biconic produced a stable and trim configuration for angles of attack from zero to 23 degrees. A significant effect of density ratio on aerodynamic coefficients, pressure distribution, and shock detachment distance was observed.

Miller, C. G.