Search NASASearch

Engineering topics

Miller, Charles

Publications and source records attributed to Miller, Charles.

At least 19 records

CARBO - The Carbon Observatory Instrument Suite - The Next Generation of Earth Observing Instruments for Global Monitoring of Carbon Gases

The Carbon Observatory Instrument Suite, or CARBO, consists of four carbon observing instruments sharing a common instrument bus, yet targeted for a particular wavelength band each with a unique science observation. They are: a) Instrument 1, wavelength centered at 756 nm for oxygen and solar-induced chlorophyll fluorescence (SIF) observations, b) Instrument 2, centered at 1629 nm, for carbon dioxide (CO2) and methane (CH4) observation, c) Instrument 3, centered at 2062 nm for carbon dioxide and d) Instrument 4, centered at 2328 for carbon monoxide (CO) and methane. From low-Earth orbit, these instruments have a field-of-view of 10 to 15 degrees, and a spatial resolution of 2 km square. These instruments have a spectral resolving power ranging from ten to twenty thousand, and can monitor columnaverage dry air mole fraction of carbon dioxide (XCO2) at 1.5 ppm, and methane (XCH4) at 7 ppb. These new instruments will advance the use of immersion grating technology in spectrometer instruments in order to reduce the size of the instrument, while improving performance. These compact, capable instruments are envisioned to be compatible with small satellites, yet modular to be configured to address the particular science questions at hand. Here we report on the current status of the instrument design and fabrication, focusing primarily on Instruments 1 and 2. We will describe the key science and engineering requirements and the instrument performance error budget. We will discuss the optical design with particular emphasis on the immersion grating, and the advantages this new technology affords compared to previous instruments. We will also discuss the status of the focal plane array and the detector electronics and housing. Finally, we report on a new approach – developed during this instrument design process - which enables simultaneous measurement of both orthogonal polarization states (S and P) over the field-of-view and optical bandpass. We believe this polarization sensing capability will enable science observations which were previously limited by instrumental and observational degeneracies. In particular: improved sensitivity to all species, better sensitivity to surface polarization effects, better constraints on aerosol scattering parameters, and superior discrimination of the vertical distribution of gases and aerosols.

Bernas, Michael

Validation of OCO-2 and ACOS-GOSAT using HIPPO and TCCON

Consistent validation of satellite CO2 estimates is a prerequisite for using multiple satellite CO2measurements for joint flux inversion and establishing a long-term atmospheric CO2 data record. Wevalidate recent satellite observation of OCO-2 v7 and ACOS-GOSAT v7.3 using similar analysis as previouswork (Kulawik et al. (2016) and Frankenberg et al. (2106)) through comparisons to the HIAPER Pole-to-Pole Observations (HIPPO) and the Total Carbon Column Observing Network (TCCON) to estimate biasesand errors affecting the understanding of carbon cycle science. CarbonTracker RT is also compared tothe validation data, and additionally used to evaluate the mismatch between the HIPPO observationtimeframe and the OCO-2 record, which are offset by 3-7 years. Some key metrics that are validatedinclude the seasonal cycle phase and amplitude, latitudinal gradient by season, regional biases, anderrors with respect to averaging.

Kulawik, Susan S.

Validation of GOSAT Data Products; Interim Report on the GOSAT/TANSO Project

The Orbiting Carbon Observatory-2 (OCO-2) Team has continued working closely with the Greenhouse Gases Observing Satellite (GOSAT) team to (i) conduct vicarious calibration experiments in Railroad Valley, NV, U.S.A., (ii) retrieve estimates of X CO2 from OCO-2 and GOSAT TANSO-FTS data, and (iii) validate these products using internationally recognized standards. The OCO-/GOSAT relationship was reinforced in March 2015 with the signing a new Memorandum of Understanding between NASA and the GOSAT and GOSAT-2 partners. Over the past year, while the GOSAT team has been finalizing the V201 product, the OCO-2 team has focused primarily on the delivery of the OCO-2 product, providing new opportunities for cross calibration of the OCO-2 and GOSAT instruments and cross validation of their products. These efforts are just now producing results. Members of the OCO-2 team have also continued the analysis of the GOSAT V161.161 data and the ACOS B3.5 products. Those efforts have produced 2 new refereed publications and several others in review. The OCO-2 now preparing to reprocess the entire GOSAT TANSO-FTS data record using the GOSAT V201 product and OCO-2 B7 algorithm to produce a 7-year, multi-satellite climate data record for X(sub CO2).

Wennberg, Paul

Geostationary Carbon Process Mapper (GCPM)

Geostationary Carbon Process Mapper (GCPM) is an earth science mission to measure key atmospheric trace gases related to climate change and human activity.Understanding of sources and sinks of CO2 is currently limited by frequency of observations and uncertainty in vertical transport. GCPM improves this situation by making simultaneous high resolution measurements of CO2, CH4, CF, and CO in near-IR, many times per day. GCPM is able to investigate processes with time scales of minutes to hours. CO2, CH4, CF, Co selected because their combination provides information needed to disentangle natural and anthropogenic sources/sinks. Quasi-continuous monitoring effectively eliminates atmospheric transport uncertainties from source/sink inversion modeling. will have one instrument (GeoFTS), hosted on a commercial communications satellite, planned for two years operation. GCPM will affordably advance the understanding of observed cycle variability improving future climate projections.

Carbon Process

The Geostationary Fourier Transform Spectrometer

The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for an earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. The GeoFTS instrument is a half meter cube size instrument designed to operate in geostationary orbit as a secondary "hosted" payload on a commercial geostationary satellite mission. The advantage of GEO is the ability to continuously stare at a region of the earth, enabling frequent sampling to capture the diurnal variability of biogenic fluxes and anthropogenic emissions from city to continental scales. The science goal is to obtain a process-based understanding of the carbon cycle from simultaneous high spatial resolution measurements of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) many times per day in the near infrared spectral region to capture their spatial and temporal variations on diurnal, synoptic, seasonal and interannual time scales. The GeoFTS instrument is based on a Michelson interferometer design with a number of advanced features incorporated. Two of the most important advanced features are the focal plane arrays and the optical path difference mechanism. A breadboard GeoFTS instrument has demonstrated functionality for simultaneous measurements in the visible and IR in the laboratory and subsequently in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson overlooking the Los Angeles basin. A GeoFTS engineering model instrument is being developed which will make simultaneous visible and IR measurements under space flight like environmental conditions (thermal-vacuum at 180 K). This will demonstrate critical instrument capabilities such as optical alignment stability, interferometer modulation efficiency, and high throughput FPA signal processing. This will reduce flight instrument development risk and show that the GeoFTS design is mature and flight ready.

Carbon exchanges

Monitoring Exchange of CO2 - A KISS Workshop Report 2009

The problem and context: Can top-down estimates of carbon dioxide (CO2) fluxes resolve the anthropogenic emissions of China, India, the United States, and the European Union with an accuracy of +/-10% or better?The workshop "Monitoring Exchange of Carbon Dioxide" was convened at the Keck Institute for Space Studies in Pasadena, California in February 2010 to address this question. The Workshop brought together an international, interdisciplinary group of 24 experts in carbon cycle science, remote sensing, emissions inventory estimation, and inverse modeling. The participants reviewed the potential of space-based and sub-orbital observational and modeling approaches to monitor anthropogenic CO2 emissions in the presence of much larger natural fluxes from the exchange of CO2 between the land, atmosphere, and ocean. This particular challenge was motivated in part by the NRC Report "Verifying Greenhouse Gas Emissions" [Pacala et al., 2010]. This workshop report includes several recommendations for improvements to observing strategies and modeling frameworks for optimal and cost-effective monitoring of carbon exchange

Greenhouse Gas Emissions