Search NASASearch

Engineering topics

Miller, E.

Publications and source records attributed to Miller, E..

At least 19 records

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations

The Visual and Infrared Mapping Spectrometer for Cassini

The Visual and Infrared Mapping Spectrometer (VIMS) is a remote sensing instrument developed for the Cassini mission to Saturn by an international team representing the national space agencies of the United States, Italy, and France. A dual imaging spectrometer, VMS' unique design consists of two optical systems boresighted and operating in tandem, coordinated by a common electronics unit.

imaging

Oscillating flow loss test results in Stirling engine heat exchangers

The results are presented for a test program designed to generate a database of oscillating flow loss information that is applicable to Stirling engine heat exchangers. The tests were performed on heater/cooler tubes of various lengths and entrance/exit configurations, on stacked and sintered screen regenerators of various wire diameters and on Brunswick and Metex random fiber regenerators. The test results were performed over a range of oscillating flow parameters consistent with Stirling engine heat exchanger experience. The tests were performed on the Sunpower oscillating flow loss rig which is based on a variable stroke and variable frequency linear drive motor. In general, the results are presented by comparing the measured oscillating flow losses to the calculated flow losses. The calculated losses are based on the cycle integration of steady flow friction factors and entrance/exit loss coefficients.

Koester, G.

Neutral mass spectrometer measurements in the shuttle bay environment

A neutral mass spectrometer, flown as part of the Induced Environment Contamination Monitor (IECM), is briefly described. Results from STS-2, -3, -4, and Spacelab 1 are qualitatively summarized. The gases observed were, for the most part, those with molecular weights below 45 amu with sources attributable to instrument background, shuttle-induced environment, and the ambient atmosphere. The most abundant gases were H2O, N2, and He. Heavier gases consisted primarily of fluorocarbons.

Miller, E.

Results from the UCSD magnetic monopole search

The energy loss mechanism for slowly moving magnetic monopoles in helium provides a means of extending the search for such particles by ionization techniques to velocities approximately 3 X 1 million cm/sec (beta approximately equals 0.0001). Other gases (e.g., CH2 or CO2) mixed with helium will be ionized with high efficiency by collisions with excited helium atoms, thus allowing the use of large proportional chamber systems for the detection of the monopoles. The first reported results utilizing this mechanism was the experiment of Kajino, et al., using a detector with an area-solid angle product alpha time delta alpha of 24.7 square meters sr. They set a limit on the flux of monopoles of 7.2 x 10 to the 13th power cm(-2) sr(-1) sec(-1) at a 90% confidence level for beta 3x 0.0001. Here, the results of a He:CH2 proportional tube array designed to extend the velocity limit down to beta approximately 0.0001 are reported. The detector which has been operating at the University of California, San Diego (UCSD) since last summer, is a prototype for a larger array currently under construction at UCSD. The data presented here is from 200 days of live time with the prototype detector.

Masek, G. E.

Boundary layer control of nocturnal convection associated with a synoptic scale system

Well defined nocturnal convection, together with distinct maximum precipitation events in Nebraska, were associated with strong diurnal wind oscillations at 850 mb in Oklahoma, Kansas and Missouri in the present study of pronounced precipitation and low level circulation variations over the Great Plains on May 5-10, 1979. A numerical prediction model, used to relate boundary layer flow modulations to synoptic scale flow for this case, is driven by a diurnal cycle. Experimental forecasts displayed diurnal wind modulations at 500 m, with rising motions of the order of 4 cm/sec at the 2200 m level, along the leading edge of the nocturnal jet.

Astling, E. G.

Shuttle on-orbit contamination and environmental effects

Ensuring the compatibility of the space shuttle system with payloads and payload measurements is discussed. An extensive set of quantitative requirements and goals was developed and implemented by the space shuttle program management. The performance of the Shuttle system as measured by these requirements and goals was assessed partly through the use of the induced environment contamination monitor on Shuttle flights 2, 3, and 4. Contamination levels are low and generally within the requirements and goals established. Additional data from near-term payloads and already planned contamination measurements will complete the environment definition and allow for the development of contamination avoidance procedures as necessary for any payload.

Leger, L. J.

Space Shuttle contamination measurements from flights STS-1 through STS-4

Results of contamination measurements performed on the initial four flights of the Space Shuttle Orbiter are summarized and compared with requirements contained in the Space Shuttle Flight and Ground System Specifications and those formulated by the Contamination Requirements Definition Group. In general, the results of measurements carried out with the induced environment contamination monitor indicate that molecular fluxes, deposition rates, and average counts of particulates are within the requirements and close to predicted values. Among the exceptions, were such special circumstances as water dumps, payload bay door closures, and RCS engine, APU, and flash evaporator operations which led to molecular and particulate contamination levels exceeding the limits. In cases where these circumstances would interfere with sensitive payload operations, careful mission planning to preclude a contamination source by operational limitation should be done to avoid losses.

Ehlers, H. K. F.

Synchronized voltage contrast display analysis system

An apparatus and method for comparing internal voltage potentials of first and second operating electronic components such as large scale integrated circuits (LSI's) in which voltage differentials are visually identified via an appropriate display means are described. More particularly, in a first embodiment of the invention a first and second scanning electron microscope (SEM) are configured to scan a first and second operating electronic component respectively. The scan pattern of the second SEM is synchronized to that of the first SEM so that both simultaneously scan corresponding portions of the two operating electronic components. Video signals from each SEM corresponding to secondary electron signals generated as a result of a primary electron beam intersecting each operating electronic component in accordance with a predetermined scan pattern are provided to a video mixer and color encoder.

Johnston, M. F.

Space Shuttle preliminary. Contamination assessment from STS-1 and STS-2

A preliminary assessment of the space shuttle contamination environment was made using data from the first two orbital flight tests, STS-1 and STS-2. Data sources consisted of crew observations during flight, postflight vehicle inspection, and the induced environment contamination monitor which was used on STS-2 and consists of 10 instruments. These instruments are used to measure gas phase contaminants, particle population, humidity, and molecular deposition in the orbiter payload bay during ascent and descent and particle population, molecular deposition, and gas cloud during orbital flight. Results of the measurements described are presented in summary form and indicate low molecular deposition rates for both pressurized and orbital flight.

Leger, L. J.

Environmental interaction implications for large space systems

Large Space Systems (LSS) comprise a new class of spacecraft, the design and performance of which may be seriously affected by a variety of environmental interactions. The special concerns associated with spacecraft charging and plasma interactions from the LSS designer's viewpoint are addressed. Survivability of these systems under combined solar U.V., particle radiation and repeated electrical discharges is of primary importance. Additional questions regard the character of electrical discharges over very large areas, the effects of high current/voltage systems and magnitude of induced structural disturbances. A concept is described for a large scale experiment platform.

Miller, E.

Spacecraft charging and plasma interaction implications for large space systems

Specific discharge mechanisms, plasma interactions, and scale effects associated with very large spacecraft are studied. The large area, low density character, and extensive use of non-conducting materials is thought to have a major impact on the performance and survivability of many large space systems.

Miller, E.

Image data processing system requirements study. Volume 1: Analysis

Digital image processing, image recorders, high-density digital data recorders, and data system element processing for use in an Earth Resources Survey image data processing system are studied. Loading to various ERS systems is also estimated by simulation.

Honikman, T.

EOS image data processing system definition study

The Image Processing System (IPS) requirements and configuration are defined for NASA-sponsored advanced technology Earth Observatory System (EOS). The scope included investigation and definition of IPS operational, functional, and product requirements considering overall system constraints and interfaces (sensor, etc.) The scope also included investigation of the technical feasibility and definition of a point design reflecting system requirements. The design phase required a survey of present and projected technology related to general and special-purpose processors, high-density digital tape recorders, and image recorders.

Gilbert, J.

Factors affecting frequency and orbit utilization by high power transmission satellite systems

The factors affecting the sharing of the geostationary orbit by high power (primarily television) satellite systems having the same or adjacent coverage areas and by satellites occupying the same orbit segment are examined and examples using the results of computer computations are given. The factors considered include: required protection ratio, receiver antenna patterns, relative transmitter power, transmitter antenna patterns, satellite grouping, and coverage pattern overlap. The results presented indicate the limits of system characteristics and orbit deployment which can result from mixing systems.

Kuhns, P. W.