Search NASA⌕ Search

Engineering topics

Miller, Eric D.

Publications and source records attributed to Miller, Eric D..

At least 19 records

The XRISM first-light observation: Velocity structure and thermal properties of the supernova remnant N 132D

Abstract We present an initial analysis of the X-Ray Imaging and Spectroscopy Mission (XRISM) first-light observation of the supernova remnant (SNR) N 132D in the Large Magellanic Cloud. The Resolve microcalorimeter has obtained the first high-resolution spectrum in the 1.6–10 keV band, which contains K-shell emission lines of Si, S, Ar, Ca, and Fe. We find that the Si and S lines are relatively narrow, with a broadening represented by a Gaussian-like velocity dispersion of $\sigma _v \sim 450$ km s$^{-1}$. However, the Fe He$\alpha$ lines are substantially broadened with $\sigma _v \sim 1670$ km s$^{-1}$. This broadening can be explained by a combination of the thermal Doppler effect due to the high ion temperature and the kinematic Doppler effect due to the SNR expansion. Assuming that the Fe He$\alpha$ emission originates predominantly from the supernova ejecta, we estimate the reverse shock velocity at the time when the bulk of the Fe ejecta were shock heated to be $-1000 \lesssim V_{\rm rs}$ (km s$^{-1}$) $\lesssim 3300$ (in the observer frame). We also find that Fe Ly$\alpha$ emission is redshifted with a bulk velocity of $\sim 890$ km s$^{-1}$, substantially larger than the radial velocity of the local interstellar medium surrounding N 132D. These results demonstrate that high-resolution X-ray spectroscopy is capable of providing constraints on the evolutionary stage, geometry, and velocity distribution of SNRs.

individual objects↗

The Evolution of Galaxies and Clusters at High Spatial Resolution with Advanced X-ray Imaging Satellite (AXIS)

Stellar and black hole feedback heat and disperse surrounding cold gas clouds, launching gas flows off circumnuclear and galactic disks, producing a dynamic interstellar medium. On large scales bordering the cosmic web, feedback drives enriched gas out of galaxies and groups, seeding the intergalactic medium with heavy elements. In this way, feedback shapes galaxy evolution by shutting down star formation and ultimately curtailing the growth of structure after the peak at redshift 2–3. To understand the complex interplay between gravity and feedback, we must resolve both the key physics within galaxies and map the impact of these processes over large scales, out into the cosmic web. The Advanced X-ray Imaging Satellite (AXIS) is a proposed X-ray probe mission for the 2030s with arcsecond spatial resolution, large effective area, and low background. AXIS will untangle the interactions of winds, radiation, jets, and supernovae with the surrounding interstellar medium across the wide range of mass scales and large volumes driving galaxy evolution and trace the establishment of feedback back to the main event at cosmic noon. This white paper is part of a series commissioned for the AXIS Probe mission concept; additional AXIS white papers can be found at the AXIS website.

47 OTHER INSTRUMENTATION↗

The Fraction of Active Galactic Nuclei in the USS 1558–003 Protocluster at $z$ = 2.53

The incidence of active galactic nuclei (AGNs) within the local environment is a potentially valuable probe of the mechanisms that trigger and provide fuel for accretion onto supermassive black holes. While the correlation between AGN fraction and environment has been well-studied in the local universe, AGN fractions have been measured for relatively few dense environments at high redshift. In this paper, we present a measurement of the X-ray AGN fraction in the USS 1558–003 protocluster associated with the $z$ = 2.53 radio galaxy 4C-00.62. Our measurement is based on a 100-ks Chandra observation, follow-up spectroscopy from the Multi-Object Double Spectrograph on the Large Binocular Telescope, and broad and narrowband photometry. These data are sensitive to AGNs more luminous than $L_X$ > 2 × 10 43 erg s -1 in the rest-frame hard X-ray band (2–10 keV). We have identified two X-ray AGNs at the redshift of USS 1558–003, one of which is the radio galaxy. We have determined that ${2.0}_{-1.3}^{+2.6} \% $ of the $Hα$ emitters in the protocluster are X-ray AGNs. Unlike most other high-redshift cluster progenitors studied with similar techniques, USS 1558–003 does not have a significantly higher fraction of AGNs than field galaxies at similar redshifts. This lower AGN fraction is inconsistent with the expectation that the higher gas fractions at high redshift, combined with the high galaxy densities and modest relative velocities in protoclusters, should produce higher AGN fractions.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Measurements of X-Ray Emission from Highly Charged Argon Ions

Uncertainties in atomic models will introduce noticeable additional systematics in calculating the flux of weak dielectronic recombination (DR) satellite lines, affecting the detection and flux measurements of other weak spectral lines. One important example is the Ar xvii Heβ DR, which is expected to be present in emission from the hot intracluster medium of galaxy clusters and could impact measurements of the flux of the 3.5 keV line that has been suggested as a secondary emission from a dark matter interaction. We perform a set of experiments using the Lawrence Livermore National Laboratory's electron beam ion trap (EBIT-I) and the X-ray Spectrometer quantum calorimeter (XRS/EBIT) to test the Ar xvii Heβ DR origin of the 3.5 keV line. We measured the X-ray emission following resonant DR onto helium-like and lithium-like Argon using EBIT-I's Maxwellian simulator mode at a simulated electron temperature of T e = 1.74 keV. The measured flux of the Ar xvii Heβ DR lined is too weak to account for the flux in the 3.5 keV line, assuming reasonable plasma parameters. We, therefore, rule out Ar xvii Heβ DR as a significant contributor to the 3.5 keV line. A comprehensive comparison between the atomic theory and the EBIT experiment results is also provided.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectral Response and Effective Area Functions of the Hitomi Imaging Instruments

We describe the tools and the underlying methods and principles for generating the spectral response functions for the four imaging instruments that were flown on the Hitomi x-ray astronomy satellite [Soft X-ray Spectrometer, or SXS; Soft X-ray Imager, or SXI, and two Hard X-ray Imagers, or HXI]. In essence, the spectral response function is a temporally and spatially averaged effective area and line-spread-function. For model-fittingx-ray spectra from an instrument, the spectral response function encapsulates the end-to-end physics of the entire system from telescope to detector, and also includes satellite attitude drift, exposure corrections, and in the case of the HXIs, drift in the telescope/detector alignment system. Accuracy in the construction of the spectral response functions is, therefore, critical to maximize the science return from the data.

Yaqoob, Tahir↗

Detection of polarized gamma-ray emission from the Crab nebula with the Hitomi Soft Gamma-ray Detector

In this study, we present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray/gamma-ray sources on the sky, and the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed data analysis of the SGD observation, SGD background estimation, and SGD Monte Carlo simulations, and successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1% ± 10.6%), and the polarization angle is 110°.7 +13°.2/-13°.0 in the energy range of 60–160 keV (the errors correspond to the 1 σ deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124° .0 ± 0° .1.

47 OTHER INSTRUMENTATION↗

Measurements of resonant scattering in the Perseus Cluster core with Hitomi SXS

Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the gas in the core of the Perseus Cluster. Here, we show that when inferring physical properties from line emissivities in systems like Perseus, the resonant scattering effect should be taken into account. In the Hitomi waveband, resonant scattering mostly affects the Fe xxv Heα line (w)—the strongest line in the spectrum. The flux measured by Hitomi in this line is suppressed by a factor of ~1.3 in the inner ~30 kpc, compared to predictions for an optically thin plasma; the suppression decreases with the distance from the center. The w line also appears slightly broader than other lines from the same ion. The observed distortions of the w line flux, shape, and distance dependence are all consistent with the expected effect of the resonant scattering in the Perseus core. By measuring the ratio of fluxes in optically thick (w) and thin (Fe xxv forbidden, Heβ, Lyα) lines, and comparing these ratios with predictions from Monte Carlo radiative transfer simulations, the velocities of gas motions have been obtained. Here, the results are consistent with the direct measurements of gas velocities from line broadening described elsewhere in this series, although the systematic and statistical uncertainties remain significant. Further improvements in the predictions of line emissivities in plasma models, and deeper observations with future X-ray missions offering similar or better capabilities to the Hitomi SXS, will enable resonant scattering measurements to provide powerful constraints on the amplitude and anisotropy of cluster gas motions.

79 ASTRONOMY AND ASTROPHYSICS↗

Hitomi observations of the LMC SNR N 132 D: Highly redshifted X-ray emission from iron ejecta

Here, we present Hitomi observations of N 132 D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16–17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km s –1 compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50–1500 km s –1 if a weakly informative prior is placed on possible line broadening. This indicates that the Fe emission arises from the supernova ejecta, and that these ejecta are highly asymmetric, since no blueshifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial mapping that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi

Here, the Hitomi Soft X-ray Spectrometer spectrum of the Perseus cluster, with ~5 eV resolution in the 2–9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic data and models. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that accurate atomic data and models are as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current data and models ready for the data from the next Hitomi-level mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Hitomi X-ray observation of the pulsar wind nebula G21.5–0.9

Here, we present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5–0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8–80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager, and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of Γ 1 = 1.74 ± 0.02 and Γ 2 = 2.14 ± 0.01 below and above the break at 7.1 ± 0.3 keV, which is significantly lower than the NuSTAR result (~9.0 keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833–1034 with the HXI and the Soft Gamma-ray Detector. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 σ. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity, and ability to measure extended sources provided by an X-ray microcalorimeter.

(stars:) pulsars: individual↗

Search for thermal X-ray features from the Crab nebula with the Hitomi soft X-ray spectrometer*

The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture (EC) explosion with a lower explosion energy by an order of magnitude than Fe-core collapse SNe. In the X-rays, imaging searches were performed for the plasma emission from the shell in the Crab outskirts to set a stringent upper limit to the X-ray emitting mass. However, the extreme brightness of the source hampers access to its vicinity. We thus employed spectroscopic technique using the X-ray micro-calorimeter onboard the Hitomi satellite. By exploiting its superb energy resolution, we set an upper limit for emission or absorption features from yet undetected thermal plasma in the 2–12 keV range. We also re-evaluated the existing Chandra and XMM-Newton data. By assembling these results, a new upper limit was obtained for the X-ray plasma mass of ≲1 M⊙ for a wide range of assumed shell radius, size, and plasma temperature both in and out of the collisional equilibrium. To compare with the observation, we further performed hydrodynamic simulations of the Crab SNR for two SN models (Fe-core versus EC) under two SN environments (uniform ISM versus progenitor wind). We found that the observed mass limit can be compatible with both SN models if the SN environment has a low density of ≲ 0.03 cm -3 (Fe core) or ≲ 0.1 cm -3 (EC) for the uniform density, or a progenitor wind density somewhat less than that provided by a mass loss rate of 10 -5 M⊙ yr -1 at 20 km s -1 for the wind environment.

79 ASTRONOMY AND ASTROPHYSICS↗

Hitomi X-ray studies of giant radio pulses from the Crab pulsar*

To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 – 300 keV band and the Kashima NICT radio observatory in the 1.4 – 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission. The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1,000 and 100 GRPs were simultaneously observed at the main and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main or inter-pulse phases. All variations are within the 2 sigma fluctuations of the X-ray fluxes at the pulse peaks, and the 3 sigma upper limits of variations of main- or inter- pulse GRPs are 22% or 80% of the peak flux in a 0.20 phase width, respectively, in the 2 – 300 keV band. The values become 25% or 110% for main or inter-pulse GRPs, respectively, when the phase width is restricted into the 0.03 phase. Among the upper limits from the Hitomi satellite, those in the 4.5-10 keV and the 70- 300 keV are obtained for the first time, and those in other bands are consistent with previous reports. Numerically, the upper limits of main- and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) ×10 -11 erg cm -2 , respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere and the number of photon-emitting particles temporally increases. However, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a > 0.02% brightening of the pulse-peak flux under such conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Hitomi observation of radio galaxy NGC 1275: The first X-ray microcalorimeter spectroscopy of Fe-Kα line emission from an active galactic nucleus*

The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February–March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275 at the center of the Perseus cluster of galaxies. With the high energy resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the Fe-Kα line with ~5.4 σ significance. The velocity width is constrained to be 500–1600 km s -1 (FWHM for Gaussian models) at 90% confidence. The SXS also constrains the continuum level from the NGC 1275 nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line. Because the velocity width is narrower than that of broad Hα line of ~2750 km s -1 , we can exclude a large contribution to the line flux from the accretion disk and the broad line region. Furthermore, we performed pixel map analyses on the Hitomi/SXS data and image analyses on the Chandra archival data, and revealed that the Fe-Kα line comes from a region within ~1.6 kpc from the NGC 1275 core, where an active galactic nucleus emission dominates, rather than that from intracluster media. Therefore, we suggest that the source of the Fe-Kα line from NGC 1275 is likely a low-covering fraction molecular torus or a rotating molecular disk which probably extends from a pc to hundreds pc scale in the active galactic nucleus system.

79 ASTRONOMY AND ASTROPHYSICS↗

Glimpse of the highly obscured HMXB IGR J16318-4848 with Hitomi*

We report a Hitomi observation of IGR J16318–4848, a high-mass X-ray binary system with an extremely strong absorption of N H ~ 10 24 cm -2 . Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer; SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and HXI) aboard Hitomi. Even though photon counts are limited due to unintended off-axis pointing, the SXS spectrum resolves Fe Kα 1 and Kα 2 lines and puts strong constraints on the line centroid and width. The line width corresponds to the velocity of $160_{-70}^{+300}$ km s -1 . This represents the most accurate, and smallest, width measurement of this line made so far from any X-ray binary, much less than the Doppler broadening and shift expected from speeds which are characteristic of similar systems. Combined with the K-shell edge energy measured by the SXI and HXI spectra, the ionization state of Fe is estimated to be in the range of Fe I–IV. Considering the estimated ionization parameter and the distance between the X-ray source and the absorber, the density and thickness of the materials are estimated. The extraordinarily strong absorption and the absence of a Compton shoulder component is confirmed. These characteristics suggest reprocessing materials which are distributed in a narrow solid angle or scattering primarily with warm free electrons or neutral hydrogen. This measurement was achieved using the SXS detection of 19 photons. This provides strong motivation for follow-up observations of this and other X-ray binaries using the X-ray Astrophysics Recovery Mission, and other comparable future instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature structure in the Perseus cluster core observed with Hitomi*

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8–20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region ~7' in diameter. The SXS was operated with an energy resolution of ~5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8–20 keV energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature Structure in the Perseus Cluster Core Observed with Hitomi

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8-20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region _ 7′ in diameter. The SXS was operated with an energy resolution of _5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components

Aharonian, Felix↗

The STAR-X X-Ray Telescope Assembly (XTA)

The Survey and Time-domain Astrophysical Research eXplorer (STAR-X) science goals are to discover what powers the most violent explosions in the Universe, understand how black holes grow across cosmic time and mass scale, and measure how structure formation heats the majority of baryons in the Universe. To achieve these goals, STAR-X requires a powerful X-ray telescope with a large field of view, large collecting area, and excellent point spread function. The STAR-X instrument, the X-Ray Telescope Assembly (XTA), meets these requirements using a powerful X-ray mirror technology based on precision-polished single crystal silicon and a mature CCD detector technology. The XTA is composed of three major subsystems: an X-ray Mirror Assembly (MA) of high resolution, lightweight mirror segments fabricated out of single crystal silicon; a Focal Plane Assembly (FPA) made of back-illuminated CCD's capable of detecting X-rays with excellent quantum efficiency; and a composite Telescope Tube that structurally links the MA and FPA. The MA consists of 5,972 silicon mirror segments mounted into five subassemblies called meta-shells. A meta-shell is constructed from an annular central structural shell covered with interlocking layers of mirror segments. This paper describes the requirements, design, and analysis of the XTA subsystems with particular focus on the MA.

NGXO↗

Astro-H Data Analysis, Processing and Archive

Astro-H (Hitomi) is an X-ray Gamma-ray mission led by Japan with international participation, launched on February 17, 2016. The payload consists of four different instruments (SXS, SXI, HXI and SGD) that operate simultaneously to cover the energy range from 0.3 keV up to 600 keV. This paper presents the analysis software and the data processing pipeline created to calibrate and analyze the Hitomi science data along with the plan for the archive and user support.These activities have been a collaborative effort shared between scientists and software engineers working in several institutes in Japan and USA.

Archive↗