Search NASA⌕ Search

Engineering topics

Miller, F. J.

Publications and source records attributed to Miller, F. J..

Opposed-Flow Flame Spread in a Narrow Channel Apparatus over Thin PMMA Sheets

Flame spread tests have been conducted over polymethylmethacrylate (PMMA) samples in San Diego State University's Narrow Channel Apparatus (SDSU NCA). The Narrow Channel Apparatus (NCA) has the ability to suppress buoyant flow in horizontally spreading flames, and is currently being investigated as a possible replacement or complement to NASA's current material flammability test standard for non-metallic solids, NASA-STD-(I)-6001B Test 1. The buoyant suppression achieved with a NCA allows for tests to be conducted in a simulated microgravity atmosphere-a characteristic that Test 1 lacks since flames present in Test 1 are buoyantly driven. The SDSU NCA allows for flame spread tests to be conducted with varying opposed flow oxidizer velocities, oxygen percent by volume, and total pressure. Also, since the test sample is placed symmetrically between two confining plates so that there is a gap above and below the sample, this gap can be adjusted. This gap height adjustment allows for a compromise between heat loss from the flame to the confining boundaries and buoyancy suppression achieved by those boundaries. This article explores the effect gap height has on the flame spread rate for 75 μm thick PMMA at 1 atm pressure and 21% oxygen concentration by volume in the SDSU NCA. Flame spread results from the SDSU NCA for thin cellulose fuels have previously been compared to results from tests in actual microgravity at various test conditions with the same sample materials and were found to be in good agreement. This article also presents results from the SDSU NCA for PMMA at 1 atm pressure, opposed oxidizer velocity ranging from 3 to 35 cm/s, oxygen concentration by volume at 21%, 30 %, and 50% and fuel thicknesses of 50 and 75 μm. These results are compared to results obtained in actual microgravity for PMMA obtained at the 4.5s drop tower of MGLAB in Gifu, Japan, and the 5.2s drop tower at NASA's Zero-Gravity Research Facility in Cleveland, OH. This comparison confirms that at 1 atm pressure, the SDSU NCA successfully simulates microgravity for not only thin cellulose fuels, but also for thin PMMA sheets as well. This further supports the idea that the NCA is a viable option to complement or replace NASA's Test 1 for material flammability testing. Tests with thick fuels will be conducted in the future to further characterize the SDSU NCA.

flame spread↗

Catalytic Ignition and Upstream Reaction Propagation in a Platinum Tube

A challenge for catalytic combustion in monolithic reactors at elevated temperatures is the start-up or "light-off" from a cold initial condition. In this work, we demonstrate a concept called "back-end catalytic ignition that potentially can be utilized in the light-off of catalytic monoliths. An external downstream flame or Joule heating raises the temperature of a small portion of the catalyst near the outlet initiating a localized catalytic reaction that propagates upstream heating the entire channel. This work uses a transient numerical model to demonstrate "back-end" ignition within a single channel which can characterize the overall performance of a monolith. The paper presents comparisons to an experiment using a single non-adiabatic channel but the concept can be extended to the adiabatic monolith case. In the model, the time scales associated with solid heat-up are typically several orders of magnitude larger than the gas-phase and chemical kinetic time-scales. Therefore, the model assumes a quasi-steady gas-phase with respect to a transient solid. The gas phase is one-dimensional. Appropriate correlations, however, account for heat and mass transfer in a direction perpendicular to the flow. The thermally-thin solid includes axial conduction. The gas phase, however, does not include axial conduction due to the high Peclet number flows. The model includes both detailed gas-phase and catalytic surface reactions. The experiment utilizes a pure platinum circular channel oriented horizontally though which a CO/O2 mixture (equivalence ratios ranging from 0.6 to 0.9) flows at 2 m/s.

Struk, P. M.↗

Quantitative Studies on the Propagation and Extinction of Near-Limit Premixed Flames Under Normal and Microgravity

The main objective of this research is to introduce accurate fluid mechanics measurements diagnostics in the 2.2-s drop tower for the determination of the detailed flow-field at the states of extinction. These results are important as they can then be compared with confidence with detailed numerical simulations so that important insight is provided into near-limit phenomena that are controlled by not well-understood kinetics and thermal radiation processes. Past qualitative studies did enhance our general understanding on the subject. However, quantitative studies are essential for the validation of existing models that subsequently be used to describe near-limit phenomena that can initiate catastrophic events in micro- and/or reduced gravity environments.

Dong, Y.↗

Fluid Management of and Flame Spread Across Liquid Pools

The goal of our research on flame spread across pools of liquid fuel remains the quantitative identification of the mechanisms that control the rate and nature of flame spread when the initial temperature of the liquid pool is below the fuel's flash point temperature. As described in, four microgravity (mu-g) sounding rocket flights examined the effect of forced opposed airflow over a 2.5 cm deep x 2 cm wide x 30 cm long pool of 1-butanol. Among many unexpected findings, it was observed that the flame spread is much slower and steadier than in 1g where flame spread has a pulsating character. Our numerical model, restricted to two dimensions, had predicted faster, pulsating flame spread in mu-g. In a test designed to achieve a more 2-D experiment, our investigation of a shallow, wide pool (2 mm deep x 78 mm wide x 30 cm long) was unsuccessful in mu-g, due to an unexpectedly long time required to fill the tray. As such, the most recent Spread Across Liquids (SAL) sounding rocket experiment had two principal objectives: 1) determine if pulsating flame spread in deep fuel trays would occur under the conditions that a state-of-the-art computational combustion code and short-duration drop tower tests predict; and 2) determine if a long, rectangular, shallow fuel tray could achieve a visibly flat liquid surface across the whole tray without spillage in the mu-g time allotted. If the second objective was met, the shallow tray was to be ignited to determine the nature of flame spread in mu-g for this geometry. For the first time in the experiment series, two fuel trays - one deep (30 cm long x 2 cm wide x 25 mm deep) and one shallow (same length and width, but 2 mm deep)-- were flown. By doing two independent experiments in a single flight, a significant cost savings was realized. In parallel, the computational objective was to modify the code to improve agreement with earlier results. This last objective was achieved by modifying the fuel mass diffusivity and adding a parameter to correct for radiative and lateral heat loss.

Ross, H. D.↗

Flame Spread Across Liquids: Experimental Results

The goal of our research on flame spread across a pool of liquid fuel is the quantitative identification of the mechanisms that control the rate and nature of flame spread when the initial temperature of the liquid pool is below the fuel's flash point temperature. Besides numerous experiments in drop towers and 1 g laboratories, we have flown five microgravity (mu-g) experiments on sounding rockets. As described in earlier papers, the first three flights examined the effect of forced opposed airflow over a 2.5 cm deep x 2 cm wide x 30 cm long pool of 1-butanol in mu-g. It was found that the flame spread is much slower and steadier than in 1 g where flame spread has a pulsating character. It was speculated that the flame spread in mu-g resembled the character of pseudo-uniform spread in 1 g; Ito et al later confirmed this conclusively in 1 g experiments. Much of the mu-g flame is also farther from the surface, dimmer, and with less soot, when compared to the 1 g flame. Three-dimensional liquid-phase flow patterns that control the liquid preheating were discovered in both 1 g and mu-g. Our numerical model, restricted to two dimensions, had predicted faster, pulsating flame spread in mu-g for opposed airflow. In examining the differences in the dimensionality of the model and experiment, it was noted that the experiment allowed gas expansion in the lateral direction (across the width of the pool), for which the model could not account. Such lateral expansion could reduce the expansion in the forward and upward directions. Because only these latter directions could be modeled, it was decided to artificially reduce the gas thermal expansion in the predictions. When this was done, satisfactory agreement could be obtained between the predicted and observed spread rates and the steadiness of the spread in microgravity. In 1 g, however, the predicted flame spread character also changed to pseudo-uniform, which disagreed with our 1 g experiments where the spread is pulsating. It was then speculated that gas-phase buoyant flow might oppose the lateral gas expansion, so that the 1 g experiments retained their pulsating flame spread character. If this speculation was valid, a difference in lateral gas expansion should be observable when comparing 1 g and mu-g experiments. Specifically, it was anticipated that greater flow divergence caused by lateral expansion would be measured in mu-g in the absence of a buoyant flow directed towards the flame.

Ross, H. D.↗