Search NASA⌕ Search

Engineering topics

Miller, F. K.

Publications and source records attributed to Miller, F. K..

Regenerator design optimization: Results from REGEN 3.3

The results from an extensive parametric study using the most recent version of the regenerator design software tool, REGEN3.3, are presented. By compiling the results from more than 10,000 applications of REGEN3.3 for three different temperatures (35 K, 60 K and 80 K), a wide range of frequencies (30–300 Hz), and a variety of regenerator length, inverse mass flux, and cold end phase angles, a group of performance maps have been generated that will enable regenerator optimization without having to learn REGEN3.3. Optimum results, defined by maximum COP values, are also provided in the form of a convenient correlation whereby the COP can be calculated directly from chosen values of cold end temperature, frequency, inverse mass flux, length, and cold end phase angle. Here one of the more interesting results revealed by this study is that the optimum value of COP is very broad. That is, changes by as much as 15% to 20% in the length, inverse mass flux, or cold end phase away from their optimized values degrade the COP by only 2%.

42 ENGINEERING↗

Development of a He{sup 3}−He{sup 4} sub Kelvin active magnetic regenerative refrigerator (AMRR) with no moving parts

Current state of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin cooling over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. We propose an active Magnetic Regenerative Refrigerator (AMRR) that uses a Superfluid Magnetic Pump (SMP) to circulate liquid He{sup 3}−He{sup 4} through a magnetic regenerator to provide the necessary cooling at sub-Kelvin temperatures. Such system will be capable of distributing the cooling load to a relatively large array of objects. One advantage of using a fluid for heat transfer in such systems is to isolate components such as the superconducting magnets from detectors that are sensitive to magnetic fields. Another advantage of the proposed tandem AMRR is that it does not need Gas Gap Heat Switches (GGHS) to transfer heat during various stages of the magnetic cooling. Our proposed system consists of four superconducting magnets, one superleak, and three heat exchangers. It will operate continuously with no moving parts and it will be capable of providing the necessary cooling at sub-Kelvin temperatures for future space science applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling results for the ITER cryogenic fore pump

The cryogenic fore pump (CFP) is designed for ITER to collect and compress hydrogen isotopes during the regeneration process of torus cryopumps. Different from common cryopumps, the ITER-CFP works in the viscous flow regime. As a result, both adsorption boundary conditions and transport phenomena contribute unique features to the pump performance. In this report, the physical mechanisms of cryopumping are studied, especially the diffusion-adsorption process and these are coupled with standard equations of species, momentum and energy balance, as well as the equation of state. Numerical models are developed, which include highly coupled non-linear conservation equations of species, momentum and energy and equation of state. Thermal and kinetic properties are treated as functions of temperature, pressure, and composition. To solve such a set of equations, a novel numerical technique, identified as the Group-Member numerical technique is proposed. It is presented here a 1D numerical model. The results include comparison with the experimental data of pure hydrogen flow and a prediction for hydrogen flow with trace helium. An advanced 2D model and detailed explanation of the Group-Member technique are to be presented in following papers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Co-Storage of Cryogenic Propellants for Lunar Explortation

Long-term storage of cryogenic propellants is a critical requirement for NASA's effort to return to the moon. Liquid hydrogen and liquid oxygen provide the highest specific impulse of any practical chemical propulsion system, and thus provides the greatest payload mass per unit of launch mass. Future manned missions will require vehicles with the flexibility to remain in orbit for months, necessitating long-term storage of these cryogenic liquids. For decades cryogenic scientific satellites have used dual cryogens with different temperatures to cool instruments. This technology utilizes a higher temperature cryogen to provide a stage that efficiently intercepts a large fraction of the heat that would otherwise be incident on the lower temperature cryogen. This interception reduces the boil-off of the lower temperature cryogen and increasing the overall life-time of the mission. The Active Co-Storage concept is implemented similarly; the 101 K liquid oxygen thermally shields the 24 K liquid hydrogen. A thermal radiation shield that is linked to the liquid oxygen tank shrouds the liquid hydrogen tank, thereby preventing the liquid hydrogen tank from being directly exposed to the 300 K external environment. Modern cryocooler technology can eliminate the liquid oxygen boil-off and also cool the thermal radiation shield thereby reducing the liquid hydrogen boil-off to a small fraction of the unshielded rate. The thermal radiation shield can be a simple conductive shroud or a more sophisticated but lighter Broad Area Cooling (BAC) shroud. The paper describes the design impact of an active co-storage system for the Altair Descent Vehicle. This paper also compares the spacecraft-level impacts of the conductive shroud and the BAC shroud active co-storage concepts with a passive storage option in the context of the different scales of spacecraft that will be used for the lunar exploration effort - the Altair Ascent and Descent Vehicles, the Orion, and the Ares V Earth Departure Stage. The paper also reports on a subscale test of this active co-storage configuration. The test tank is 0.7 m in diameter, approximately one-third the dimension of tanks that would be needed in a lunar ascent module. A thin-walled fiberglass skirt supports and isolates the tank from a 100 K stage. A similar thin-walled skirt supports the lOOK stage from the ambient temperature structure. An aluminum shield with a heavy MLI blanket surrounds the tank and is attached at the 100 K stage. In this initial phase of the project, there is no tank on the 100 K stage, but it is actively cooled by a single-stage cryocooler similar in design to the one used on the RHESSI mission. The test configuration includes a number of innovative elements, including a helical support heat exchanger and an external thermodynamic vent/heat interception system. To avoid the complexity of an explosive gas handling system, testing will be done with liquid helium and liquid neon as simulant fluids. The properties of these fluids bracket the properties of liquid hydrogen. Instrumentation allows tank temperature and shield temperature profiles, tank liquid levels, and pressure drops through the flow lines, to be measured.

Mustafi, S.↗

Optimized Heat Interception for Cryogen Tank Support Structure

We consider means for using the cooling available in boil-off gas to intercept heat conducted through the support structure of a cryogen tank. A one-dimensional model of the structure coupled to a gas stream gives an analytical expression for heat leak in terms of flow rate for temperature independent properties and laminar flow. A numerical model has been developed for heat transfer on a thin cylindrical tube with an attached vent line. The model is used to determine the vent path layout that will minimize heat flow into the cryogen tank. The results are useful for a number of applications, but the one of interest in this study is the minimization of the boil-off in large cryopropellant tanks in low Earth and low lunar orbit.

Canavan, E. R.↗

Optimized Heat Interception for Cryogen Tank Support

We consider means for using the cooling available in boil-off gas to intercept heat conducted through the support structure of a cryogen tank. A one-dimensional model of the structure coupled to a gas stream gives an analytical expression for heat leak in terms of flow rate for temperature independent-properties and laminar flow. A numerical model has been developed for heat transfer on a thin cylindrical tube with an attached vent line. The model is used to determine the vent path layout that will minimize heat flow into the cryogen tank. The results are useful for a number of applications, but the one of interest in this study is the minimization of the boil-off in large cryopropellant tanks in low Earth and low lunar orbit.

Canavan, Edgar R.↗