Search NASA⌕ Search

Engineering topics

Mitchell, Mark

Publications and source records attributed to Mitchell, Mark.

26 records · Page 2

Contamination Control and Hardware Processing Solutions at Marshall Space Flight Center

The Contamination Control Team of Marshall Space Flight Center's Materials and Processes Laboratory supports many Programs/ Projects that design, manufacture, and test a wide range of hardware types that are sensitive to contamination and foreign object damage (FOD). Examples where contamination/FOD concerns arise include sensitive structural bondline failure, critical orifice blockage, seal leakage, and reactive fluid compatibility (liquid oxygen, hydrazine) as well as performance degradation of sensitive instruments or spacecraft surfaces such as optical elements and thermal control systems. During the design phase, determination of the sensitivity of a hardware system to different types or levels of contamination/FOD is essential. A contamination control and FOD control plan must then be developed and implemented through all phases of ground processing, and, sometimes, on-orbit use, recovery, and refurbishment. Implementation of proper controls prevents cost and schedule impacts due to hardware damage or rework and helps assure mission success. Current capabilities are being used to support recent and on-going activities for multiple Mission Directorates / Programs such as International Space Station (ISS), James Webb Space Telescope (JWST), Space Launch System (SLS) elements (tanks, engines, booster), etc. The team also advances Green Technology initiatives and addresses materials obsolescence issues for NASA and external customers, most notably in the area of solvent replacement (e.g. aqueous cleaners containing hexavalent chrome, ozone depleting chemicals (CFC s and HCFC's), suspect carcinogens). The team evaluates new surface cleanliness inspection and cleaning technologies (e.g. plasma cleaning), and maintains databases for processing support materials as well as outgassing and optical compatibility test results for spaceflight environments.

Burns, DeWitt H.↗

Detection of Natural Oil Seeps in the Atlantic Ocean Using MODIS

Natural oil seepage is the release of crude oil into the ocean from fissures in the seabed. Oil seepage is a major contributor to the total amount of oil entering the world s oceans. According to a 2003 study by the National Academy of Sciences (NAS), 47 percent of oil entering the world s oceans is from natural seeps, and 53 percent is from human sources (extraction, transportation, and consumption). Oil seeps cause smooth oil slicks to form on the water s surface. Oil seeps can indicate the location of stores of fossil fuel beneath the ocean floor. Knowledge of the effect of oil seepage on marine life and marine ecosystems remains limited. In the past, remote sensing has been used to detect oil seeps in the Gulf of Mexico and off of the coast of southern California. This project utilized sun glint MODIS imagery to locate oil slicks off of the Atlantic coast, an area that had not previously been surveyed for natural oil seeps using remote sensing. Since 1982, the Atlantic Ocean has been closed to any oil and gas drilling. Recently, however, the U.S. Minerals Management Services (MMS) has proposed a lease for oil and gas drilling off the coasts of Virginia and North Carolina. Determining the location of seepage sites in the Atlantic Ocean will help MMS locate potential deposits of oil and natural gas, thereby reducing the risk of leasing areas for petroleum extraction that do not contain these natural resources.

Reahard, Ross↗

Bond Assembly FOD Zones - A Procedure for Assuring Acceptable Adhesion

Rocket motor components are primarily assembled by adhesion. a) For example, the RSRM (Reusable Solid Rocket Motor - part of the Space Shuttle Boosters) system contains 10,000 sq ft of bondline area. b) Rocket motors contain a variety of adhesive/substrate bond systems c) Bond system performance requirements also vary. To assemble reliable components, ATK Space Systems and customers invest substantial resources to the study of bond assembly processes. a) Surface and adhesion science; b) Adhesive chemistry; c) Process parameters; d) Contamination effects.

Evans, Kurt↗

Next Generation Nuclear Plant Phenomena Identification and Ranking Tables (PIRTs) Volume 5: Graphite PIRTs

Here we report the outcome of the application of the Nuclear Regulatory Commission (NRC) Phenomena Identification and Ranking Table (PIRT) process to the issue of nuclear-grade graphite for the moderator and structural components of a next generation nuclear plant (NGNP), considering both routine (normal operation) and postulated accident conditions for the NGNP. The NGNP is assumed to be a modular high-temperature gas-cooled reactor (HTGR), either a gas-turbine modular helium reactor (GTMHR) version [a prismatic-core modular reactor (PMR)] or a pebble-bed modular reactor (PBMR) version [a pebble bed reactor (PBR)] design, with either a direct- or indirect-cycle gas turbine (Brayton cycle) system for electric power production, and an indirect-cycle component for hydrogen production. NGNP design options with a high-pressure steam generator (Rankine cycle) in the primary loop are not considered in this PIRT. This graphite PIRT was conducted in parallel with four other NRC PIRT activities, taking advantage of the relationships and overlaps in subject matter. The graphite PIRT panel identified numerous phenomena, five of which were ranked high importance-low knowledge. A further nine were ranked with high importance and medium knowledge rank. Two phenomena were ranked with medium importance and low knowledge, and a further 14 were ranked medium importance and medium knowledge rank. The last 12 phenomena were ranked with low importance and high knowledge rank (or similar combinations suggesting they have low priority). The ranking/scoring rationale for the reported graphite phenomena is discussed. Much has been learned about the behavior of graphite in reactor environments in the 60-plus years since the first graphite rectors went into service. The extensive list of references in the Bibliography is plainly testament to this fact. Our current knowledge base is well developed. Although data are lacking for the specific grades being considered for Generation IV (Gen IV) concepts, such as the NGNP, it is fully expected that the behavior of these graphites will conform to the recognized trends for near isotropic nuclear graphite. Thus, much of the data needed is confirmatory in nature. Theories that can explain graphite behavior have been postulated and, in many cases, shown to represent experimental data well. However, these theories need to be tested against data for the new graphites and extended to higher neutron doses and temperatures pertinent to the new Gen IV reactor concepts. It is anticipated that current and planned future graphite irradiation experiments will provide the data needed to validate many of the currently accepted models, as well as providing the needed data for design confirmation.

08 HYDROGEN↗

Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

Figueroa, Fernando↗

Strain Gage Measurement System to Determine Cryogenic Propellant Tank Level

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult proposition. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. This paper describes a simple, but effective method to determine propellant volume by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a very good quality signal even during pressurization.

Figueroa, Fernando↗

Experimental Evaluation of White Light Fabry-Perot Interferometry Fiber-Optic Strain Gages when Measuring Small Strains

An experimental study was conducted to evaluate whether fiber optic strain gages (FOSG) are "better" sensors than typical foil gages. A particularly attractive feature of FOSG was their specified resolution of 0.01% of full-scale (0.1 micro strain for 1000 micro strain full-scale). This feature would make FOSG practical tank level sensors, by measuring very small strains on the support structure of a tank. A specific application in mind was to measure liquid oxygen tank level, with support beams that were predicted to contract approximately 11 micro strain as the tank goes from empty to full. Among various fiber optic technologies currently available, Fabry-Perot Interferometry using white light was selected. This technology exhibits highly desirable feature such as absolute strain measurement, linearity over its full-scale, and temperature compensation. However, experiment results suggest that the resolution is 0.8 micro strain, at best, calibration from one sensor to another can be off by 2.4 - 11.2%, and that temperature compensation is not fully predictable, with errors of up to 3.5 micro strain over an 11C range. Hence, when compared with classic foil gages, FOSG possess less accuracy, similar resolution and repeatability (precision), and superior linearity over their entire operating range. They are immune to EMI and their signals suffer minimal degradation over long distances. It is also expected that drift with time will be minimal in FOSG whereas the gage factor of foil sensors changes over time when exposed to varying environmental conditions. In conclusion, FOSG are "better" than foil gages as long as the application allows calibration of individual units as installed for operation.

St.Cyr, William↗

Thermocouple Extension-Wire-Connections and Low Temperatures

Experiments were carried out to determine the casue of erroneous readings from thermocouples of type K when measuring temperatures of liquid hydrogen. It was believed to be linked to te temperature of the connector used to extend the thermocouple wires to the voltage meter.

Figueroa, Fernando↗