Search NASA⌕ Search

Engineering topics

Mitra, A.

Publications and source records attributed to Mitra, A..

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

High quality superconducting Nb co-planar resonators on sapphire substrate

We present measurements and simulations of superconducting Nb co-planar waveguide resonators on sapphire substrate down to millikelvin temperature range with different readout powers. In the high temperature regime, we demonstrate that the Nb film residual surface resistance is comparable to that observed in the ultra-high quality, bulk Nb 3D superconducting radio frequency cavities while the resonator quality is dominated by the BCS thermally excited quasiparticles. At low temperature both the resonator quality factor and frequency can be well explained using the two-level system models. Through the energy participation ratio simulations, we find that the two-level system loss tangent is $\sim 10^{-2}$, which agrees quite well with similar studies performed on the Nb 3D cavities.

Zhu, S.↗