Search NASA⌕ Search

Engineering topics

Mix, La Moyne Tyler

Publications and source records attributed to Mix, La Moyne Tyler.

Flux and estimated spectra from a low-intensity laser-driven X-ray source

Laser-driven X-rays as probes for high-energy-density physics spans an extremely large parameter space with laser intensities varying by 8 orders of magnitude. We have built and characterized a soft X-ray source driven by a modest intensity laser of 4 × 10 13 W/cm 2 . Emitted X-rays were measured by diamond radiation detectors and a filtered soft X-ray camera. A material-dependence study on Al, Ti, stainless steel alloy 304, Fe, Cu and Sn targets indicated 5-μm-thick Cu foils produced the highest X-ray yield. X-ray emission in the laser direction and emission in the reverse direction depend strongly on the foil material and the thickness due to the opacity and hydrodynamic disassembly time. The time-varying X-ray signals are used to measure the material thinning rate and is found to be ~1.5 μm/ns for the materials tested implying thermal temperature around 0.6 eV. The X-ray spectra from Cu targets peaks at ~2 keV with no emission >4 keV and was estimated using images with eight different foil filters. One-dimensional hydrodynamic and spectral calculations using HELIOS-CR provide qualitative agreement with experimental results. Modest intensity lasers can be an excellent source for nanosecond bursts of soft X-rays.

47 OTHER INSTRUMENTATION↗

Robust unfolding of MeV x-ray spectra from filter stack spectrometer data

Here, we present an inversion method capable of robustly unfolding MeV x-ray spectra from filter stack spectrometer (FSS) data without requiring an a priori specification of a spectral shape or arbitrary termination of the algorithm. Our inversion method is based upon the perturbative minimization (PM) algorithm, which has previously been shown to be capable of unfolding x-ray transmission data, albeit for a limited regime in which the x-ray mass attenuation coefficient of the filter material increases monotonically with x-ray energy. Our inversion method improves upon the PM algorithm through regular smoothing of the candidate spectrum and by adding stochasticity to the search. With these additions, the inversion method does not require a physics model for an initial guess, fitting, or user-selected termination of the search. Instead, the only assumption made by the inversion method is that the x-ray spectrum should be near a smooth curve. Testing with synthetic data shows that the inversion method can successfully recover the primary large-scale features of MeV x-ray spectra, including the number of x-rays in energy bins of several-MeV widths to within 10%. Fine-scale features, however, are more difficult to recover accurately. Examples of unfolding experimental FSS data obtained at the Texas Petawatt Laser Facility and the OMEGA EP laser facility are also presented.

47 OTHER INSTRUMENTATION↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗