Overview of Shielding Analyses at Oak Ridge National Laboratory’s Spallation Neutron Source Second Target Station

The Neutronics Group of the Second Target Station project at Oak Ridge National Laboratory is responsible for all neutronics analyses related to design and construction. This paper provides an overview of four neutronics analyses performed for the Second Target Station project, which is representative of all the ongoing work but especially tasks related to shielding. These analyses extend from the proton accelerator through the target monolith and bunker to the end of a neutron beamline. Each example highlights the tools and methods the Neutronics Group uses for analysis. The primary tool is the Monte Carlo radiation transport code MCNP 6.2, but this is augmented by other codes that supplement the input of MCNP. The other codes specifically highlighted in this paper include Attila4MC, ADVANTG, and AARE.

Miller, Thomas↗

Second Target Station Bunker Shielding with Populated and Unpopulated Neutron Beamlines: Preliminary Design

At the U.S. Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. Prompt total effective dose rates (i.e., neutron plus photon effective dose rates when the proton beam is on) were calculated on top of the bunker roof and outside the bunker wall. These areas outside the bunker will be generally accessible, so the prompt total dose rate in these areas should not exceed 2.5 μSv . h -1 (0.25 mrem . h -1 ). This paper presents the required shielding thicknesses to meet this dose rate limit. In one instance, this dose rate limit is not met: For a combination of populated and unpopulated beamlines, the prompt total dose rate outside the bunker across from the unpopulated beamline, which has less shielding because of the lack of beamline shielding, slightly exceeds 2.5 μSv . h -1 . In conclusion, once more details are known regarding the STS high-density concrete density and composition, a future analysis will investigate the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 2.5 μSv . h -1 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Target Station (STS) Project: Analysis of Bunker Shielding–Preliminary Design

At the Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. The simulations in this report used the ST11 beamline source, primarily the ST11 neutron source, because that source provides conservative prompt total dose rate estimates for all beamlines. Prompt total dose rates (i.e., neutron plus photon dose rates when the beam is on) were calculated on top of the bunker roof, outside the bunker wall, and in the basement below the bunker and instrument floor. Design changes were made to ensure the prompt total dose rate in these areas does not exceed 0.25 mrem/h. This report documents the required shielding thicknesses to meet this dose rate limit. There is one exception to this: for a combination of open and closed beamlines, the prompt total dose rate outside the bunker across from the closed beamline, where there is less shielding due to the lack of beamline shielding, slightly exceeds 0.25 mrem/h. A future analysis will document the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 0.25 mrem/h once more details regarding the STS high density concrete density and composition are known. Finally, prompt total dose rates inside the bunker were simulated. The results of this simulation show that the majority of prompt total dose rate in the bunker is due to neutrons, and a few percent of the total is caused by secondary photons created by the neutrons. The contribution to prompt total dose rate inside the bunker by the primary photons that enter each beamline from the target/moderator area is at least two orders of magnitude less than the neutron contribution. This means prompt total dose rate contributions due to primary photons inside and outside the bunker can be neglected.