Characterization Testing of Lockheed Martin Micro1-2 Cryocoolers Optimized for 220 K Environment

The Mapping Imaging Spectrometer for Europa (MISE) Instrument on the Europa Clipper mission has baselined a Lockheed Martin high-power Micro1-2 pulse tube cryocooler operating at 135 Hz with a 220 K heat rejection temperature. This paper describes the testing and results of two Lockheed Martin Micro1-2 coolers optimized for these conditions. The thermal performance of the microcoolers was measured in vacuum for heat reject temperatures between 220 and 230 K. The coolers were operated with input powers ranging from 5 W to 40 W and drive frequency between 125 Hz and 145 Hz. The optimal drive frequency was strongly dependent on heat reject temperature. In addition, the exported forces and torques of the coolers were measured at 300 K heat rejection for input powers ranging from 5 W to 60 W and drive frequency between 120 Hz and 160 Hz. The exported forces were dependent on both piston amplitude and drive frequency. Moreover, the following were measured on one of the coolers: DC and AC magnetic fields at various locations, the off-state conductance of the pulse tube, and the effect of inclination angle of the pulse tube relative to gravity on the performance of the cooler. Finally, one of the coolers was subjected to random vibration testing.

Rodriguez, J.I.↗

Low Temperature Characterization of Mechanical Isolators for Cryocoolers

For spacecraft applications requiring active refrigeration, exported vibrations from a cryocooler can be a concern. One approach to minimizing the vibrations transmitted from cryocoolers to the spacecraft is to mount them on mechanical isolators. Many commercial off-theshelf (COTS) mechanical isolators exist and have been characterized at room temperature for ground applications. However, the space environment presents challenges that complicate the selection process. Mechanical isolators in space must be made of materials that can withstand harsh radiation environments. Future instruments, such as the Mapping Imaging Spectrometer for Europa (MISE) on the Europa Clipper mission, are considering operating cryocoolers with low heat rejection temperatures and mounting them on mechanical isolators. However, the performance of many simple, traditional mechanical isolators at low temperatures is unknown. This paper describes the testing and results of various mechanical isolators able to withstand harsh radiation between 200 K and 300 K. The transmissibility of wire rope type isolators showed very little temperature dependence up to ~500 Hz. On the other hand, the transmissibility of silicone gel was strongly dependent on temperature as the material had an abrupt change in stiffness near its solid-solid phase change. Custom titanium flexures showed the most promise with a maximum transmissibility of 0.04 above 500 Hz and no expected temperature dependence.

Rodriguez, J.I.↗