Radiation Source Localization Algorithm in the Pedestrian Radiation Portal Monitor
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Mondal, Kunal.
Explore the source record for details and available documents.
Not Available
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A sensor for passively measuring a maximum temperature within a nuclear reactor comprises a substrate, and a plurality of melt wires within a cavity defined within the substrate, at least one melt wire of the plurality of melt wires exhibiting a variable melting temperature along a length of the at least one melt wire. Related sensors and methods of forming the sensors are also disclosed.
Advanced manufacturing techniques and digital twin technology are rapidly transforming the nuclear industry, offering the potential to enhance productivity, safety, and cost-effectiveness. Customized parts are being produced using additive manufacturing, automation, and robotics, while digital twin technology enables the virtual modeling and optimization of complex systems. These advanced technologies can significantly improve operational efficiency, predict system behavior, and optimize maintenance schedules in the nuclear energy sector, leading to heightened safety and reduced downtime. However, the nuclear industry demands the highest levels of safety and security, as well as intricate manufacturing processes and operations. Thus, challenges such as data management and cybersecurity must be addressed to fully realize the potential of advanced manufacturing techniques and digital twin technology in the nuclear industry. This comprehensive review highlights the critical role of digital twin technology with advanced manufacturing toward nuclear energy to improve performance, minimize downtime, and heighten safety, ultimately contributing to the global energy mix by providing dependable and low-carbon electricity.
The purpose of this study is to utilize waste products—precipitated calcium carbonate (PCC) and upcycled recycled concrete aggregate (upcycled RCA or UCA)—in civil works projects. To do so, tests must be performed to determine the engineering properties of the materials in which PCC and UCA are sequestered. PCC is a fine to coarse grain waste product generated during the production of sugar from sugar beets. UCA is produced from demolished and returned concrete by the extraction of primarily calcium and alkalinity. The study also includes the use of both PCC and UCA in the same concrete mix design. The test results on PCC alone show that the optimum content to achieve a minimum 28 MPa (4000 psi) compressive strength is 25% and 30%. The corresponding compressive strength of mixes in which conventional aggregate was replaced by UCA is about 48 MPa (7000 psi) to 55 MPa (8000 psi) at the same water: cement ratio (0.44) by weight. The compressive strength of concrete with 25% to 30% cement replaced by PCC and varying aggregates replaced with UCA ranges from 19.3 to 40 MPa (2800 to 5800 psi). Other tests on PCC and UCA include tensile strength of 2 to 3 MPa (293 to 423 psi) and flexural strength of 1.3 to 1.9 MPa (183 to 279 psi). Analytical techniques such as X-ray diffraction (XRD), energy-dispersive X-ray spectrometry (EDX), and scanning electron microscopy (SEM) were used to identify the constituent elements and chemical compounds present in PCC, including calcium carbonate and silica. Based on the test results, the composition of PCC by weight indicates 45.9% calcium, 39.4% oxygen, and 9.2% carbon. Based on the results of this study, we can expect to reduce carbon emissions in the production of cement and aggregates, as well as utilize waste products in the civil engineering field.
Advanced voloxidation with NO 2 is a proposed process for used nuclear fuel head-end reprocessing scheme that converts UO 2 to higher oxides, and it also converts partitioning volatile fission products into the gas phase, thus facilitating fuel dissolution and actinide recovery. NO 2 voloxidation is being studied on small batches of UO 2 Simfuel, but the real test of process feasibility will be when it is scaled up to work with >100 g of irradiated material. This report discusses the aspects of scale-up that must be considered for NO 2 voloxidation, including development of a stirred reactor to promote agitation of the mixture during processing, online process monitoring, and automation controls. Brief details on parallel efforts are also provided in this report, including (a) demonstration of iodine release from Simfuel made by Spark Plasma Sintering, and (b) development of an order-of-magnitude scale-up to react 100 g of UO 2 Simfuel in a metal reactor.
Abstract To reduce global warming, many countries are shifting to sustainable energy production systems. Solid oxide electrolysis cells (SOECs) are being considered due to their high hydrogen generation efficiency. However, low faradaic efficiency in scaling SOEC technology affects costs and limits large-scale adoption of hydrogen as fuel. This review covers SOECs’ critical aspects: current state-of-the-art anode, cathode, and electrolyte materials, operational and materials parameters affecting faradaic efficiency, and computational modeling techniques to resolve bottlenecks affecting SOEC faradaic efficiency.
The utilization of bio-functionalities such as biorecognition or catalysis derived them their name biosensors. Bio-electrochemical sensing is a new discipline that combines the advantages of biological detection and electrochemical transduction. Bio-electrochemical sensors are devices that use biological materials such as enzymes, antibodies, DNA, or cells as receptors to detect target analytes in a variety of samples. Electrodes convert biological interactions into electrical impulses, which can be studied using various electrochemical techniques. Bio-electrochemical sensors have demonstrated significant promise for use in clinical diagnostics, environmental monitoring, food safety, and biotechnology. Biosensors have received numerous applications in recent years because they are fast, simple, and inexpensive for practical applications. In this article, we cover the basic principles, design strategies, immobilization and regeneration techniques, along with the advantages and applications of bio-electrochemical sensors. Finally, this article discusses the rationale for developing electrochemical biosensors in the context of the various bio-receptors that can be applied.
Energy storage has always been a major concern in the present-day situation. Advanced energy storage devices are batteries, supercapacitor and solar cells. However, advancements have been noteworthy in the field of high-performance hybrid supercapacitors. On this note, we have fabricated a hybrid supercapacitor electrode material Potassium tantalate nano cube (KT NCs) and its reduced graphene oxide composite (KT-rGO NCs) and tested its electrochemical performance. The materials showed high performances with specific capacitance of 565 F/g for KT NCs and 850 F/g for KT-rGO NCs respectively. Energy densities of both KT NCs & KT-rGO NCs are 28.24 Wh/Kg and 29.50 Wh/kg with good retention capacities. Further detailed study of both KT NCs and KT-rGO NCs are carried out with characterization techniques like XRD, FTIR, BET, Raman and HRTEM for structural analysis and electrochemical measurements to analyse various parameters pertaining to its charge storage capacity.
Silicon carbide nanowires (SiC NWs) exhibit promising features to allow solution-processable electronics to be deployed in harsh environments. By utilizing a nanoscale form of SiC, we were able to disperse the material into liquid solvents, while maintaining the resilience of bulk SiC. Here, this letter reports the fabrication of SiC NW Schottky diodes. Each diode consisted of just one nanowire with an approximate diameter of 160 nm. In addition to analyzing the diode performance, the effects of elevated temperatures and proton irradiation on the current–voltage characteristics of SiC NW Schottky diodes were also examined. The device could maintain similar values for ideality factor, barrier height, and effective Richardson constant upon proton irradiation with a fluence of 10 16 ion/cm 2 at 873 K. As a result, these metrics have clearly demonstrated the high-temperature tolerance and irradiation resistance of SiC NWs, ultimately indicating that they may provide utility in allowing solution-processable electronics in harsh environments.
Wearable electronic devices (WEDs) are receiving significant attention because of the increasing interest in soft robotics, electronic skin, and wearable sensors. Liquid metals (LMs) are compelling for WEDs owing to their metallic conductivity, fluidic nature, and low toxicity. For this study, we fabricated stretchable and soft WEDs using LM (eutectic gallium-indium alloy) wires (LMWs) patterned via force wetting through custom-made stencils on an elastic substrate. LMWs can generate thermal energy via Joule heating upon current application and deliver it to the substrate, resulting in wearable polymeric heaters. The LM mixed with carbonyl iron particles (CIPs) can also be patterned while preserving fluidic behavior. The degree of thermal energy generated through the LMWs can be manipulated as a function of the CIP concentration in the LM and geometrical factors of the electrode patterns, i.e., width and length. An elastic film patterned with LMWs attached to the human body exhibits changes in the effective electrical resistance depending on applied strain, demonstrating potential as a wearable strain sensor. This LM utilized WED that can generate thermal energy upon current application through the LMWs and detect the bodily motion has significant potential for application in wearable thermotherapy, electronic skin, and soft sensors.
In this work, we report the fabrication of Ni and Cu tubular substrates and the synthesis of ZnO/CuO nanocomposite on them through the process of pulse electrodeposition. The systematic variation in CuO incorporation in the ZnO matrix and the processing technique were noticed to affect the structural, optical, photocatalytic, and anti-bacterial properties, which are well in accordance with the Field Emission-Scanning Electron Microscope, X-ray Diffraction, Fourier transform Infrared Spectroscopy and UV-Differential reflectance spectroscopy results. The remediation capabilities of the photocatalytic substrates were assessed through the degradation of methylene blue (MB) dye under solar irradiation. Optimized CuO incorporation within the ZnO nanorods resulted in the degradation of a 20 ppm of MB dye solution within 40 min and a higher concentration of 50 ppm within 95 min. The Ni and Cu electroformed tubes as substrates provided not only a reusable supporting frame but also a large surface-area for the growth of ZnO/CuO nanocomposite. The current study also dealt with the anti-bacterial efficacy of the above-mentioned substrates against E.coli. Hence, the Ni and Cu tubular thin film substrates with nanorods of ZnO/CuO composite were explored for the removal of organic as well as biological contaminants from waste water.
The present study involves detecting and determining CIP by a new electrochemical sensor based on graphene (Gr) in the presence of sodium dodecyl sulfate (SDS) employing voltammetric techniques. Surface morphology studies of the sensing material were analyzed using a scanning electron microscope (SEM) and atomic force microscope (AFM). In the electroanalysis of CIP at the developed electrode, an enhanced anodic peak response was recorded, suggesting the electro-oxidation of CIP at the electrode surface. Furthermore, we evaluated the impact of the electrolytic solution, scan rate, accumulation time, and concentration variation on the electrochemical behavior of CIP. The possible electrode mechanism was proposed based on the acquired experimental information. A concentration variation study was performed using differential pulse voltammetry (DPV) in the lower concentration range, and the fabricated electrode achieved a detection limit of 2.9 × 10 -8 M. The proposed sensor detected CIP in pharmaceutical and biological samples. The findings displayed good recovery, with 93.8% for tablet analysis and 93.3% to 98.7% for urine analysis. The stability of a developed electrode was tested by inter- and intraday analysis.
A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.
In this research, detection of trimethoprim (TMP) was carried out using a nanostructured zinc oxide nanoparticle-modified carbon paste electrode (ZnO/CPE) with an anionic surfactant and sodium dodecyl sulphate (SDS) with the help of voltametric techniques. The electrochemical nature of TMP was studied in 0.2 M pH 3.0 phosphate-buffer solution (PBS). The developed electrode displayed the highest peak current compared to nascent CPE. Effects of variation in different parameters, such as pH, immersion time, scan rate, and concentration, were investigated. The electrode process of TMP was irreversible and diffusion controlled with two electrons transferred. The effective concentration range (8.0 × 10 -7 M–1.0 × 10 -5 M) of TMP was obtained by varying the concentration with a lower limit of detection obtained to be 2.58 × 10 -8 M. In addition, this approach was effectively employed in the detection of TMP in pharmaceutical dosages and samples of urine with the excellent recovery data, suggesting the potency of the developed electrode in clinical and pharmaceutical sample analysis.