Search NASA⌕ Search

Engineering topics

Monte, A.

Publications and source records attributed to Monte, A..

Qualification and Performance of a High-Efficiency Laser Transmitter for Deep-Space Optical Communications

A high-power Laser Transmitter Assembly (LTA) was developed to support the Deep Space Optical Communications (DSOC) technology demonstration being developed by the Jet Propulsion Laboratory. NASA’s Psyche Mission plans to host the DSOC flight subsystem for testing space-to-ground high-bandwidth laser communications en route to the 16 Psyche asteroid. We review the design, performance, and qualification of the LTA Engineering Model and Flight Model (EM and FM) delivered to JPL. The LTA uses a master-oscillator power amplifier (MOPA) design and delivers up to 4.5 W at 1550 nm, with a highly efficient, cladding-pumped, polarization-maintaining erbium-ytterbium fiber amplifier. The master oscillator generates a range of pulse widths and repetition rates to support modulation formats from 16- to 128-PPM for optical data transmission at >100 Mbps. The LTA was designed for high reliability and radiation hardness, and includes redundant signal and pumping paths to reduce single points of failure, hardware interlocks to ensure safe operation and protection against damage, closed-loop control of optical power, and detailed health and status via telemetry. The LTA EM and FM were subjected to unit-appropriate space qualification testing. We describe the performance testing of the EM and FM, for the characterization of key metrics such as wavelength stability, signal linewidth, optical pulse width, jitter, and extinction ratio, and polarization extinction ratio. The management of optical nonlinearities (self-phase modulation, Brillouin scattering, or pulse-to-pulse energy variation), which could result in an optical link penalty or damage to the LTA, is also detailed, and factors affecting the power efficiency are discussed.

Jaques, J.↗

Measurement of charge and light yields for 127 Xe L -shell electron captures in liquid xenon

Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using β -decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inner-shell electrons. Such events lead to emission of x rays and Auger electrons, resulting in higher electron-ion recombination and thus a more NR-like response than inferred from β -decay calibration. We present a cross-calibration of tritium β -decays and Xe 127 electron-capture decays (which produce inner-shell vacancies) in a small-scale LXe-TPC and give the most precise measurements to date of light and charge yields for the Xe 127 L -shell electron-capture in liquid xenon. We observe a 6.9 σ ( 9.2 σ ) discrepancy in the L -shell capture response relative to tritium β decays, measured at a drift field of 363 ± 14 V / cm ( 258 ± 13 V / cm ), when compared to simulations tuned to reproduce the correct β -decay response. In dark matter searches, use of a background model that neglects this effect leads to overcoverage (higher limits) for background-only multi-kiloton-year exposures, but at a level much less than the 1 - σ experiment-to-experiment variation of the 90% C.L. upper limit on the interaction rate of a 50 GeV / c 2 dark matter particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical quantum sensing in the search for dark matter

Numerous astrophysical and cosmological observations are best explained by the existence of dark matter, a mass density which interacts only very weakly with visible, baryonic matter. Here, searching for the extremely weak signals produced by this dark matter strongly motivate the development of new, ultra-sensitive detector technologies. Paradigmatic advances in the control and readout of massive mechanical systems, in both the classical and quantum regimes, have enabled unprecedented levels of sensitivity. In this white paper, we outline recent ideas in the potential use of a range of solid-state mechanical sensing technologies to aid in the search for dark matter in a number of energy scales and with a variety of coupling mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗

Measurement of the ion fraction and mobility of 218Po produced in 222Rn decays in liquid argon

We report measurements of the charged daughter fraction of 218Po as a result of the 222Rn alpha decay, and the mobility of 218Po+ ions, using radon-polonium coincidences from the 238U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of 218Po that is charged is found to be 0.37 ± 0.03 and the mobility of 218Po+ is (8.6 ± 0.1) × 10-4 cm2/Vs.

Agnes, P↗

Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

Here, we report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CALIS—A CALibration Insertion System for the DarkSide-50 dark matter search experiment

This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10 7 , using the pulse shape discrimination technique, and the measurement of the residual 39 Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of low electric fields on alpha scintillation light yield in liquid argon

Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. Furthermore, the light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide experiment: Present status and future

Here, DarkSide is a multi-stage program devoted to direct searches of Dark Matter particles with detectors based on double phase liquid Argon Time Projection Chamber. The DarkSide-50 setup is running underground at the Laboratori Nazionali del Gran Sasso. First it was operated with Atmospheric Argon and during that run (1422 ± 67) kg×d of truly background-free exposure has been accumulated. Obtained data made it possible to set a 90% C.L. upper limit on the WIMP-nucleon cross section of 6.1 × 10 –44 cm 2 (for a WIMP mass of 100 GeV/c 2 ). Presently the detector is filled with Underground Argon, which is depleted in 39 Ar by a factor of (1.4 ± 0.2)×10 3 with respect to Atmospheric Argon. Acquired so far (2616 ± 43) kg×d (71 live days) in combination with the data from the Atmospheric Argon run give us the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0×10 –44 cm 2 for a WIMP mass of 100 GeV/c 2 . Up to date this is the best limit obtained with an argon target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DarkSide-50 Experiment: a Liquid Argon Target for Dark Matter Particles

The DarkSide-50 experiment, located at the “Laboratori Nazionali del Gran Sasso (INFN)”, is based on low-radioactivity argon double phase time projection chamber, surrounded by an active liquid scintillator veto, designed for the zero background achievement. The liquid argon features sufficient self shielding and easy scalability to multi-tons scale. The impressive reduction of the 39 Ar isotope (compared to the atmospheric argon), along with the excellent pulse shape discrimination, make this technology a possible candidate for the forthcoming generation of multi-ton Dark Matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide awakens

Here, the DarkSide program at LNGS aims to perform background-free WIMP searches using two phase liquid argon time projection chambers, with the ultimate goal of covering all parameters down to the so-called neutrino floor. One of the distinct features of the program is the use of underground argon with has a reduced content of the radioactive 39 Ar compared to atmospheric argon. The DarkSide Collaboration is currently operating the DarkSide-50 experiment, the first such WIMP detector using underground argon. Operations with underground argon indicate a suppression of 39 Ar by a factor (1.4 ± 0.2) × 10 3 relative to atmospheric argon. The new results obtained with DarkSide-50 and the plans for the next steps of the DarkSide program, the 20t fiducial mass DarkSide-20k detector and the 200 t fiducial Argo, are reviewed in this proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results From the First Use of Low Radioactivity Argon in a Dark Matter Search

Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar39 at a level reduced by a factor (1.4±0.2)×103 relative to atmospheric argon. We report a background-free null result from (2616±43) kg d of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0×10-44 cm2 (8.6×10-44 cm2, 8.0×10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2, 10 TeV/c2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The veto system of the DarkSide-50 experiment

Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗