Montgomery, E. F.

Publications and source records attributed to Montgomery, E. F..

Laboratory and telescope use of the NICMOS2 128 x 128 HgCdTe array

The second generation of Hubble Space Telescope (HST) instruments will include a near-infrared instrument. This choice has driven the development of near-infrared arrays to larger sizes and lower read noises. Rockwell International has delivered an array for use in the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) instrument; this array has been dubbed NICMOS2. NICMOS2 is a 128x128 array of HgCdTe diodes In-bonded to a switched MOSFET readout. The readout was specifically designed for astronomical use with the HST requirement of low read noise a prime goal. These arrays use detector material which is similar to that used by Rockwell in previous arrays (e.g., HgCdTe produced on a sapphire substrate), but the NICMOS2 devices differ substantially from other 128x128 arrays produced by Rockwell in having a read noise of only 30 electrons when read out using appropriate correlated sampling. NICMOS2 has now been characterized in the laboratory, and it has been used on groundbased telescopes.

Rieke, Marcia J.↗

Evaluation of Rockwell HgCdTe arrays for astronomical use

The 32 x 32 HgCdTe array manufactured by Rockwell International was proven to be a highly competitive detector type for use at wavelengths shorter than 2.5 microns. The goal of a K=+16 sky survey using this array attached to the Steward Observatory Transit Telescope is clearly within reach. The detector material exhibits high quantum efficiency and low dark currents indicating that its usefulness may extend beyond its use with a CCD readout on groundbased telescopes.

Lebofsky, M. J.↗

Unidentified features in the spectrum of Triton

Photometry at 3.5 microns was taken with the Infrared Telescope Facility of the Multiple Mirror Telescope to obtain an improved IR spectrum of Triton. The observations show features that are not in detailed agreeement with previous identifications of methane or methane frost, although the general spectral behavior leading to such identifications has been confirmed. It is believed that a combination of surface and atmospheric absorptions may resolve some discrepancies; for instance, many hydrated minerals and frosts which are dark between 3.0 and 4.0 microns may combine with a carbon monoxide atmosphere to yield the data in question.

Rieke, G. H.↗

High sensitivity operation of discrete solid state detectors of 4 K

Techniques are described to allow operation of discrete solid state detectors at 4 K with optimized junction field effect transistor (JFET) amplifiers. Three detector types cover the 0.6-4 micron spectral range with a noise equivalent power (NEP) of approximately 10 to the -16th per sq rt Hz for two of the types and potential improvement to this performance for the third. Lower NEPs can be anticipated at longer IR wavelengths.

Rieke, G. H.↗

High sensitivity operation of discrete solid state detectors at 4 K

Techniques are described to allow operation of discrete, solid state detectors at 4 K with optimized JFET amplifiers. Three detector types cover the 0.6 to 4 mm spectral range with NEP approximately equal to 10 to the 16th power Hz (-1/2) for two of the types and potential improvement to this performance for the third. Lower NEP's are anticipated at longer infrared wavelengths.

Rieke, G. H.↗