Search NASA⌕ Search

Engineering topics

Montgomery, L. D.

Publications and source records attributed to Montgomery, L. D..

At least 19 records

Physiologic and thermal responses of male and female patients with multiple sclerosis to head and neck cooling

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the thermal and physiologic responses of patients with multiple sclerosis to short-term maximal head and neck cooling. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 24 female and 26 male patients with multiple sclerosis in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 degrees C), were cooled for 30 min by the liquid cooling garment, which was operated at its maximum cooling capacity. Oral, right, and left ear temperatures and cooling system parameters were logged manually every 5 min. Forearm, calf, chest, and rectal temperatures, heart rate, and respiration rate were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. This protocol was performed during the winter and summer to investigate the seasonal differences in the way patients with multiple sclerosis respond to head and neck cooling. No significant differences were found between the male and female subject group's mean rectal or oral temperature responses during any phase of the experiment. The mean oral temperature decreased significantly (P < 0.05) for both groups approximately 0.3 degrees C after 30 min of cooling and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 15 min after removal of the cooling helmet. The mean rectal temperatures decreased significantly (P < 0.05) in both male and female subjects in the winter studies (approximately 0.2-0.3 degrees C) and for the male subjects during the summer test (approximately 0.2 degrees C). However, the rectal temperature of the female subjects did not change significantly during any phase of the summer test. These data indicate that head and neck cooling may, in general, be used to reduce the oral and body temperatures of both male and female patients with multiple sclerosis by the approximate amount needed for symptomatic relief as shown by other researchers. However, thermal response of patients with multiple sclerosis may be affected by gender and seasonal factors, which should be considered in the use of liquid cooling therapy.

NASA Discipline Environmental Health↗

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC↗

Rheoencephalographic and electroencephalographic measures of cognitive workload: analytical procedures

This investigation demonstrates the feasibility of mental workload assessment by rheoencephalographic (REG) and multichannel electroencephalographic (EEG) monitoring. During the performance of this research, unique testing, analytical and display procedures were developed for REG and EEG monitoring that extend the current state of the art and provide valuable tools for the study of cerebral circulatory and neural activity during cognition. REG records are analyzed to provide indices of the right and left hemisphere hemodynamic changes that take place during each test sequence. The EEG data are modeled using regression techniques and mathematically transformed to provide energy-density distributions of the scalp electrostatic field. These procedures permit concurrent REG/EEG cognitive testing not possible with current techniques. The introduction of a system for recording and analysis of cognitive REG/EEG test sequences facilitates the study of learning and memory disorders, dementia and other encephalopathies.

Arousal/physiology↗

Cortical localization of cognitive function by regression of performance on event-related potentials

This paper demonstrates a new method of mapping cortical localization of cognitive function, using electroencephalographic data. Cross-subject regression analyses are used to identify cortical sites and post-stimulus latencies where there is a high correlation between subjects' performance and their cognitive event-related potential amplitude. The procedure was tested using a mental arithmetic task and was found to identify essentially the same cortical regions that have been associated with such tasks on the basis of research with patients suffering localized cortical lesions. Thus, it appears to offer an inexpensive, noninvasive tool for exploring the dynamics of localization in neurologically normal subjects.

Montgomery, R. W.↗

Cardiovascular dynamics associated with tolerance to lower body negative pressure

The purpose of this investigation was to identify cardiovascular responses associated with tolerance to lower body negative pressure (LBNP). Eighteen men, ages 29-51 years, were categorized as high (HT) or low (LT) LBNP-tolerant based on a graded presyncopal-limited LBNP exposure criterion of -60 mm Hg relative to ambient pressure. Groups were matched for physical characteristics and pre-LBNP cardiovascular measurements, with the exceptions of greater (p less than 0.05) end-diastolic volume and cardiac output in the HT group. During peak LBNP, cardiac output was similar in both groups, although the HT group displayed a greater heart rate (p less than 0.05). In both groups, venous return appeared to limit cardiac output resulting in decreased arterial pressure. Tolerance to LBNP did not appear solely dependent on the absolute amount of blood pooled in the legs since the HT group demonstrated a greater (p less than 0.05) peak LBNP-induced increase in midthigh-leg volume. Greater tolerance to LBNP was associated with a larger pre-LBNP cardiac output reserve and higher compensatory increases in heart rate and peripheral resistance.

Sather, T. M.↗

Cardiovascular responses during orthostasis - Effect of an increase in maximal O2 uptake

A study is described which tests the hypothesis that changes in aerobic activity (increases in maximum oxygen uptake) will reduce the effectiveness of cardiovascular reflexes to regulate blood pressure during orthostasis. The hypothesis was tested by measuring heart rate, blood pressure and blood volume responses in eight healthy male subjects before and after an eight-day endurance regimen. The results of the study suggest that the physiologic responses to orthostasis are dependent upon the rate of plasma volume loss and pooling, and are associated with training-induced hypervolemia. It is indicated that endurance type exercise training enhances cardiovascular adjustments during tilt. The implications of these results for the use of exercise training as a countermeasure and/or therapeutic method for the prevention of cardiovascular instability during orthostatic stress are discussed.

Convertino, V. A.↗

Use of impedance plethysmography to continually monitor bone marrow blood flow

An impedance-plethysmographic technique is described which can be used to quantify temporal bone-marrow blood-flow changes. Results obtained with the impedance technique compare favorably with the data from simultaneously administered microspheres. Injection of sympathomimetic drugs produced measurable responses: isoproterenol caused a significant increase in bone-marrow blood flow within 1 min, and levarterenol decreased bone-marrow blood flow. Data obtained with impedance plethysmography suggest that the technique is feasible for multiple measurements on the same animal and that the technique can be used to study acute or chronic changes in bone-marrow blood flow following various experimental treatments.

Montgomery, L. D.↗

Thermoregulatory responses of rats to varying environmental temperatures

The peripheral (tail) circulatory responses of six male albino rats were measured at ambient temperatures between 5 and 40 C, using impedance plethysmography. Each animal was anesthetized, instrumented, and placed in a thermal environmental chamber to reach equilibrium. Tail blood flow, respiration rate, heart rate, core temperature, and tail skin temperature were then monitored at each ambient temperature. The mean tail blood flow was significantly higher (p less than 0.05) at 5 C than at 10 C. The mean blood flow increased significantly (p less than 0.01) at each of the temperatures above 10 C. Tail skin temperature and internal body (core) temperature increased significantly with increasing ambient temperature.

Berry, J. J.↗

A comparison of limb plethysmograph systems proposed for use on the Space Shuttle

Comparisons of a Whitney mercury-filled double-stranded strain gauge with two plethysmographs proposed for Shuttle use - an ultrasound and an impedance plethysmograph - were performed on 20 subjects. An occlusive thigh pressure cuff, inflated to 50 mm Hg, caused partial venous occlusion and subsequent blood pooling distal to the cuff. The average maximum volume changes observed in the Whitney/ultrasound test were 2.07% and 3.35%, respectively, and 2.12% and 2.53% for the Whitney/Impedance comparison. Applying the ratio of the maximum volume changes to the gain of each test system caused the impedance and ultrasound volume change determinations to be essentially identical to the Whitney gauge. The three different limb parameters measured result in significant magnitude differences but the three systems track their respective changes identically.

Levitan, B. M.↗

Development of a prototype automatic controller for liquid cooling garment inlet temperature

The development of a computer control of a liquid cooled garment (LCG) inlet temperature is descirbed. An adaptive model of the LCG is used to predict the heat-removal rates for various inlet temperatures. An experimental system that contains a microcomputer was constructed. The LCG inlet and outlet temperatures and the heat exchanger outlet temperature form the inputs to the computer. The adaptive model prediction method of control is successful during tests where the inlet temperature is automatically chosen by the computer. It is concluded that the program can be implemented in a microprocessor of a size that is practical for a life support back-pack.

Weaver, C. S.↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

Limb blood flow - Rest and heavy exercise in sitting and supine positions in man

The objectives of the study were twofold: (1) to determine the effect of body position (hydrostatic pressure) on total blood flow in active and passive limbs at rest and after severe exercise; and (2) to further evaluate the impedance technique for measurement of blood flow. To this end, the effect of body position on the redistribution of total blood flow in active (leg) and passive (forearm) limbs during exercise was determined by measuring total limb impedance (blood flow) in five male and one female subjects in sitting and supine positions with a modified Beckman BR-100 rheograph. The results show that, at rest and after exercise, the supine position induces significantly greater flows in the leg but not in the forearm. With severe exercise, blood flows are increased in both passive and active limbs, so that there is probably no net transfer of blood volume from passive to active muscles. The advantages of the impedance technique over other methods are stressed.

Greenleaf, J. E.↗

Effect of sodium and calcium ingestion on thermoregulation during exercise in man

The effects of hypertonic sodium and calcium ingestion on body temperature during exercise in cool and hot environments are investigated. Rectal and mean skin temperatures, sweat rates and arm and leg total blood flows were measured in men during periods of rest, submaximal exercise and recovery at temperatures of 26.5 C and 39.4 C after ingestion of NaCl and CaCl2 solutions. In both environments, higher rectal temperatures are observed after hypertonic sodium ingestion, which is also associated with attenuated blood flow in the extremities, lower sweat rates and slightly higher skin temperature in the heat, indicating significant thermoregulatory responses. Hypertonic calcium and isotonic sodium cause no temperature change, although calcium caused a reduction of blood flow in the extremities.

Greenleaf, J. E.↗

Effect of hypovolemia, infusion, and oral rehydration on plasma electrolytes, ADH, renin activity, and +G/z/ tolerance

Effects on plasma volume, electrolyte shifts, and +G(z) tolerance induced by: (1) blood withdrawal; (2) blood infusion; and (3) oral fluid intake, were determined at 0.5 G/min in centrifugation tests of six ambulatory male patients, aged 21 to 27 yrs. Hypovolemia induced by withdrawal of 400 ml blood, blood infusion followed by repeated centrifugation, effects of consuming an isotonic drink (0.9% NaCl) to achieve oral rehydration, and donning of red adaptation goggles were studied for effects on acceleration tolerance, pre-acceleration and post-acceleration plasma renin activity (PRA) and plasma vasopressin levels. No significant changes in post-acceleration PRA compared to pre-acceleration PRA were found, and administration of oral rehydration is found as effective as blood replacement in counteracting hypovolemic effects.

Greenleaf, J. E.↗

An electrode system for tetrapolar electrical impedance plethysmography of the finger

A rigid band electrode system is described which facilitates location of the recording electrodes of a tetrapolar impedance plethysmograph used for measuring pulsations of blood in a finger segment. The electrodes can be relocated accurately, and the volume of the finger segment under study can be precisely defined. The new system ensures good electrical contact and minimizes movement artifacts in the plethysmograph trace by holding the finger segment in a firm position.

Montgomery, L. D.↗

Variation of forearm, hand, and finger blood flow indices with ambient temperature

Forearm, hand, and finger blood flow (impedance) changes are measured by impedance rheography on seven healthy male subjects aged 20-35 yr during exposure to ambient temperatures ranging from 10 to 46 C. All observations are made in an environmental chamber at a dew point temperature of 13 + or - 0.25 C. It is shown that impedance rheography is suitable for quantifying peripheral circulatory responses to thermal stress. The measured blood flow indices are found to be consistent with previously reported values for the forearm, hand, and fingers obtained using air or water displacement plethysmography. In particular, the more distal body segments exhibit relatively larger vasomotor responses to changes in ambient temperature than do the more proximal body segments.

Montgomery, L. D.↗

Cardiovascular responses of men and women to lower body negative pressure

Changes in blood flow and blood redistribution were measured by impedance plethysmography in the pelvic and leg regions of six male and four female subjects during three 5-min exposures to -20, -40, and -60 mm Hg lower body negative pressure (LBNP). Female subjects demonstrated significantly higher mean heart rate and lower leg blood flow indices than the male subjects during the recumbent control periods. Men had slightly higher mean resting systolic and diastolic blood pressures and higher mean control pelvic blood indices. Women demonstrated significantly less blood pooling in the legs and slightly less in the pelvic region than the men. All of the 18 tests with male subjects at -60 mm Hg were completed without initial signs of syncope, while only two of the tests with women were completed successfully without the subject exhibiting presyncopal conditions. Results indicate that impedance plethysmography can be used to measure segmental cardiovascular responses during LBNP and that females may be less tolerant to -60 mm Hg LBNP than males.

Montgomery, L. D.↗

Effect of hypovolemia, infusion, and oral rehydration on gradual onset +Gz acceleration tolerance

The purpose of this study was to determine the effect of blood withdrawal, blood infusion, and oral fluid intake on +Gz tolerance at an acceleration rate of 0.5 G/min. Six healthy men aged 21-27 yr were centrifuged after the withdrawal of 400 ml of blood (hypovolemia) from each man; they were centrifuged again following blood infusion (Phase I). Three weeks later the men were accelerated after similar hypovolemia and again after consuming 800 ml of an isotonic NaCl drink (Phase II). Phase I hypovolemia resulted in a reduction in tolerance in all subjects from a mean control level of 6.42 + or - 0.35 min to 5.45 + or - 0.17 min (-15.1%, p less than 0.05). Both infusion and drinking returned tolerances to control levels. During acceleration there were significant (p less than 0.05) increases in plasma vasopressin levels to 35 pg/ml; these were not influenced appreciably by infusion or drinking. In all acceleration runs there was an obligatory shift (loss) of plasma volume and electrolytes, especially potassium, regardless of the experimental treatments. Oral rehydration is shown to be as effective as blood replacement in restoring +Gz acceleration tolerance decrements due to hypovolemia.

Greenleaf, J. E.↗