Search NASA⌕ Search

Engineering topics

Moore, Douglas

Publications and source records attributed to Moore, Douglas.

Context Cameras for the Orbiting Carbon Observatory 3 (OCO-3) Instrument

We have developed an adaptable camera platform that takes advantage of screened and qualified commercial off the shelf (COTS) components (CMOS sensor, rad-tolerant microcircuits, lenses) to significantly shorten development time of space-borne visible imaging systems while reducing the overall cost and risk of the development. This modular camera platform is implemented as a suite of two visible-light cameras for the Orbiting Carbon Observatory 3 (OCO-3) instrument at NASA’s Jet Propulsion Laboratory (JPL). The Internal Context Camera (ICC) and External Context Camera (ECC) provide contextual engineering imaging support for the calibration of the OCO-3 instrument, intended to significantly reduce the duration of the mission’s calibration campaign. The OCO-3 mission has taken advantage of the design and qualification work performed by JPL’s Mars 2020 Enhanced Engineering Camera (EECam) team in reusing the qualified COTS CMOS imaging sensor, proven electronic designs, and scalable field-programmable gate array (FPGA) firmware to meet OCO-3’s mission requirements and resource availability. We will be presenting the steps taken by JPL to design, build, and test the Context Cameras for the OCO-3 mission. We will highlight the design deviations from the Mars2020 EECams and discuss the methodology of tailoring the EECam design for the OCO-3 requirements. Camera imaging capabilities, including focal plane and optical performance, will be presented, as well as a summary of the calibration and environmental test results. Finally, we will discuss the potential for future applications for the Context Cameras.

Moore, Douglas↗

Low Order Wavefront Sensing and Control for WFIRST Coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

wavefront sensing and control↗

Low order wavefront sensing and control for WFIRST coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

Wilson, Dan↗

Low Order Wavefront Sensing and Control for WFIRST-AFTA Coronagraph

To maintain the required WFIRST Coronagraph performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C use s the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading of the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST -AFTA Coronagraph. We will describe LOWFS/C's Zernike wavefront sensor concept and WFIRST LOWFS/C control design. We will present an overview of our analysis and modeling results on the Zernike wavefront sensor, the line -of-sight jitter suppression loop performance, as well as the low order wavefront error correction with the coronagraph's deformable mirror. In this paper we will also report the LOWFS/C testbed design and the preliminary in-air test results, which show a very promising performance of the Zernike wavefront sensor and FSM feedback loop.

exoplanets↗

Measurement of the Non-common Vertex Error of a Double Corner Cube

The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.

Space Interferometry Mission (SIM)↗