Search NASA⌕ Search

Engineering topics

Moore, Steven

Publications and source records attributed to Moore, Steven.

DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility

We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.

Balewski, Jan↗

DEMONSTRATION OF 3D EFFECTS WITH HIGH GAIN AND EFFICIENCY IN A UV FEL OSCILLATOR

We report on the performance of a high gain UV FEL oscillator operating on an energy recovery linac at Jefferson Lab. The high brightness of the electron beam leads to both gain and efficiency that cannot be reconciled with a one-dimensional model. Three-dimensional simulations do predict the performance with reasonable precision. Gain in excess of 100% per pass and an efficiency close to 1/2NW, where NW is the number of wiggler periods, is seen. The laser mirror tuning curves currently permit operation in the wavelength range of 438 to 362 nm. Another mirror set allows operation at longer wavelengths in the red with even higher gain and efficiency.

43 PARTICLE ACCELERATORS↗

Design of the SRF Driver ERL for the Jefferson Lab UV FEL

We describe the design of the SRF Energy-Recovering Linac (ERL) providing the CW electron drive beam at the Jefferson Lab UV FEL. Based on the same 135 MeV linear accelerator as and sharing portions of the recirculator with the Jefferson Lab 10 kW IR Upgrade FEL, the UV driver ERL uses a novel bypass geometry to provide transverse phase space control, bunch length compression, and nonlinear aberration compensation (including correction of RF curvature effects) without the use of magnetic chicanes or harmonic RF. Stringent phase space requirements at the wiggler, low beam energy, high beam current, and use of a pre-existing facility and legacy hardware subject the design to numerous constraints. These are imposed not only by the need for both transverse and longitudinal phase space management, but also by the potential impact of collective phenomena (space charge, wakefields, beam break-up (BBU), and coherent synchrotron radiation (CSR)), and by interactions between the FEL and the accelerator RF system. This report addresses these issues and presents the accelerator design solution that is now in operation.

43 PARTICLE ACCELERATORS↗

JLab FEL DC Gun

The Jefferson Lab (JLab) Energy Recovery Linac 10 kW IR Upgrade Free Electron Laser (FEL) is driven by a 350kV DC un-polarized photoemission electron gun. In 2003, an upgrade version of the earlier 1 kW IR Demo FEL gun delivered over 1000 Coulombs with a single Cs:GaAs wafer in one year of operation. Between 2004 and 2007 a second wafer delivered over 7000 Coulombs and up to 9 mA CW beam for FEL operations. Both wafers suffered surface damage with total loss of quantum efficiency in several occasions during high current operations. Since then, the electron gun has been refurbished two times due to field emission damage. Although presently operating at nominal 350kV, field emission has significantly decreased the photocathode lifetime.

Hernandez-Garcia, Carlos↗

ETHERNET BASED EMBEDDED IOC FOR FEL CONTROL SYSTEM

An Ethernet based embedded Input Output Controller (IOC) has been developed to upgrade the control system for the Free Electron Laser Project at Jefferson Lab. The embedded IOC, called the Single Board IOC (SBIOC), was integrated with a ColdFire embedded microprocessor and a Field Programmable Gate Array (FPGA) on a circuit board, which can be easily configured to control different kinds of I/O devices. The SBIOC provided features of a complete System-on-Module (SOM) as a stand alone system with abundant high speed I/O ports to couple with suitable devices. The software kits, Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS), were chosen to work with our existing control system. The embedded IOC system has the features of a low cost IOC, free open source RTOS, plug-and-play-like ease of installation and flexibility.

43 PARTICLE ACCELERATORS↗

Ethernet Based Embedded IOC for FEL Control Systems

An Ethernet based embedded Input Output Controller (IOC) has been developed as part of an upgrade to the control system for the Free Electron Laser Project at Jefferson Lab. Currently most of the FEL systems are controlled, configured and monitored using a central VME bus-based configuration. These crate based systems are limited in growth and usually interleave multiple systems. In order to accommodate incremental system growth and lower channel costs, we developed a stand-alone system, an Ethernet based embedded controller called the Single Board IOC (SBIOC). The SBIOC is a module which integrates an Altera FPGA and the Arcturus uCdimm Coldfire 5282 Microcontroller daughter card into one module, which can be easily configured for different kinds of I/O devices. The microcontroller is a complete System-on-Module, including three highly integrated functional blocks, the core processor, memory, and Ethernet communication. A real-time operating system, RTEMS is cross compiled with

97 MATHEMATICS AND COMPUTING↗

Ocular Counter-Rolling During Centrifugation and Static Tilt

Activation of the gravity sensors in the inner ear-the otoliths-generates reflexes that act to maintain posture and gaze. Ocular counter-rolling (OCR) is an example of such a reflex. When the head is tilted to the side, the eyes rotate around the line of sight in the opposite direction (i.e., counter-rolling). While turning comers, undergoing centrifugation, or making side-to-side tilting head movements, the OCR reflex orients the eyes towards the sum of the accelerations from body movements and gravity. Deconditioning of otolith-mediated reflexes following adaptation to microgravity has been proposed as the basis of many of the postural, locomotor, and gaze control problems experienced by returning astronauts. Evidence suggests that OCR is reduced postflight in about 75% of astronauts tested; but the data are sparse, primarily due to difficulties in recording rotational eye movements. During the Neurolab mission, a short-arm human centrifuge was flown that generated sustained sideways accelerations of 0.5-G and one-G to the head and upper body. This produces OCR; and so for the first time, the responses to sustained centrifugation could be studied without the influence of Earth's gravity on the results. This allowed us to determine the relative importance of sideways and vertical acceleration in the generation of OCR. This also provided the first test of the effects of exposure to artificial gravity in space on postflight otolith-ocular reflexes. There was little difference between the responses to centrifugation in microgravity and on Earth. In both conditions, the induced OCR was roughly proportional to the applied acceleration, with the OCR magnitude during 0.5-G centrifugation approximately 60% of that generated during one-G centrifugation. The overall mean OCR from the four payload crewmembers in response to one-G of sideways acceleration was 5.7 plus or minus 1.1 degree (mean and SD) on Earth. Inflight one-G centrifugation generated 5.7 plus or minus 1.1 degree of OCR, which was a small but significant decrease in OCR magnitude. The postflight OCR was 5.9 plus or minus 1.4 degree, which was not significantly different from preflight values. During both 0.5-G and one-G centrifugation in microgravity, where the head vertical gravitational component was absent, the OCR magnitude was not significantly different from that produced by an equivalent acceleration during static tilt on Earth. This suggests that the larger OCR magnitude observed during centrifugation on Earth was due to the larger body vertical linear acceleration component, which may have activated either the otoliths or the body tilt receptors. In contrast to previous studies, there was no decrease in OCR gain postflight. Our findings raise the possibility that inflight exposure to artificial gravity, in the form of intermittent one-G and 0.5-G centripetal acceleration, may have been a countermeasure to deconditioning of otolith-based orientation reflexes.

Cohen, Bernard↗