FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons

Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those at the temperature of interest because of the latter's unavailability. The present studies are designed to address the differences between the calculated and experimental thermal emission spectra and to provide information which will be useful in future ultraviolet induced infrared fluorescence studies. The emission spectra have been obtained for temperatures up to 825K using an emission cell designed to mount against an external port of an FT-IR spectrometer. These spectra provide information concerning relative band intensities and peak positions which is unavailable from previous calculations.

Salisbury, D. W.

On PAHs as interstellar grains - Infrared absorption coefficients

Consideration is given to the proposal that PAHs are the source of IR continuum and emission features and the visible diffuse bands. Absolute IR cross-sections have been obtained for eight PAHs. The results show that a thermal continuum is not consistent with the spectra obtained, and that an array of normal molecules shows a spectrum that is more complex than the observed spectrum. The cross-sections of the UV spectra are 2-3 orders of magnitude larger than those of the IR spectra. It is suggested that, to account for these observations, structure must be produced in the UV extinction curve.

Salisbury, D. W.

Laboratory infrared spectra of predicted condensates in carbon-rich stars

Laboratory spectra and mass absorption coefficients of MgS, CaS, FeS, SiS2, FeS2, Fe3C, and a commercial iron carbide are presented over the wavelength range 125-15 microns. These spectra confirm that MgS is the most likely source of the unidentified 30-micron emission in carbon-rich sources and that FeS, Fe3C, and 'iron carbide' cannot be responsible for this feature although they could contribute to the continuum in this region. CaS and FeS2 may contribute to the 30-micron feature; however, both higher resolution and higher precision astronomical observations are needed before their presence can be established. SiS2 has a peak near 22 microns and therefore cannot be a significant component of the dust in such regions.

Nuth, J. A.

Spectral response from blackbody measurements

Far-infrared and submillimeter detector responsivity and spectral response measurements can be performed simultaneously by sweeping the temperature of a cooled blackbody. Such measurements yield n simultaneous linear equations for n blackbody temperatures. Matrix inversion solutions are observed to fail due to a matrix ill-conditioned for inversion. However, an unconditionally convergent iterative solution can be performed. Results for a gallium-doped germanium detector are described.

Moore, W. J.

Low background spectral response of 30-130-micron detectors from blackbody measurements

Low background far infrared detector responsivity and low background spectral response calibrations can be performed simultaneously with a cooled, temperature-swept blackbody. This makes the use of a cooled, low background spectrometer unnecessary in many applications. Calibrations of a beryllium-doped germanium detector showing unwanted 100-micron response, and of a gallium-doped germanium detector, are described.

Moore, W. J.

Gallium-doped germanium, evaluation of photoconductors, part 1

Gallium-doped germanium far infrared detectors were evaluated at low temperatures and low background simulating the space environment. Signal and noise characteristics were determined for detector temperatures in the 2K to 4K range. Optimum performance occurs at about 2.5K for all devices tested. The minimum average NEP in the 40-130 micron region was found to be approximately 4 x 10 to the minus 17th power watt Hz(-1/2) at a frequency of 1 Hz.

Moore, W. J.

Far infrared observations of IRC + 10216

Results are reported for measurements of IRC + 10216 at 100 microns made with the 91-cm telescope of NASA's Kuiper Airborne Infrared Observatory. The IR photometer employed consisted of a gallium-doped germanium photoconductive detector with a MOSFET preamplifier and load resistor. Signals obtained from the source at modulation frequencies of 30 and 100 Hz are plotted, and the 100-micron flux measurements are shown to be in agreement with previous bolometric measurements. It is noted that the sensitivity of the photoconductive detection system is comparable to that of the conventional bolometers that have been used in airborne IR observations.

Shivanandan, K.

The 100 micron detector development program

An effort to optimize gallium-doped germanium photoconductors (Ge:Ga) for use in space for sensitive detection of far infrared radiation in the 100 micron region is described as well as the development of cryogenic apparatus capable of calibrating detectors under low background conditions.

Moore, W. J.