Search NASA⌕ Search

Engineering topics

Moreno, Jose

Publications and source records attributed to Moreno, Jose.

Compensation of Oxygen Transmittance Effects for Proximal Sensing Retrieval of Canopy-Leaving Sun-Induced Chlorophyll Fluorescence

Estimates of Sun-Induced vegetation chlorophyll Fluorescence (SIF) using remote sensing techniques are commonly determined by exploiting solar and/or telluric absorption features. When SIF is retrieved in the strong oxygen (O2) absorption features, atmospheric effects must always be compensated. Whereas correction of atmospheric effects is a standard airborne or satellite data processing step, there is no consensus regarding whether it is required for SIF proximal-sensing measurements nor what is the best strategy to be followed. Thus, by using simulated data, this work provides a comprehensive analysis about how atmospheric effects impact SIF estimations on proximal sensing, regarding: (1) the sensor height above the vegetated canopy; (2) the SIF retrieval technique used, e.g., Fraunhofer Line Discriminator (FLD) family or Spectral Fitting Methods (SFM); and (3) the instrument's spectral resolution. We demonstrate that for proximal-sensing scenarios compensating for atmospheric effects by simply introducing the O2 transmittance function into the FLD or SFM formulations improves SIF estimations. However, these simplistic corrections still lead to inaccurate SIF estimations due to the multiplication of spectrally convolved atmospheric transfer functions with absorption features. Consequently, a more rigorous oxygen compensation strategy is proposed and assessed by following a classic airborne atmospheric correction scheme adapted to proximal sensing. This approach allows compensating for the O2 absorption effects and, at the same time, convolving the high spectral resolution data according to the corresponding Instrumental Spectral Response Function (ISRF) through the use of an atmospheric radiative transfer model. Finally, due to the key role of O2 absorption on the evaluated proximal-sensing SIF retrieval strategies, its dependency on surface pressure (p) and air temperature (T) was also assessed. we combined simulated spectral data with p and T measurements obtained for a one-year period in the Hyytiala Forestry Field Station in Finland. Of importance hereby is that seasonal dynamics in terms of T and p, if not appropriately considered as part of the retrieval strategy, can result in erroneous SIF seasonal trends that mimic those of known dynamics for temperature-dependent physiological responses of vegetation.

"sun–induced chlorophyll fluorescence (SIF); pro↗

How Universal is the Relationship Between Remotely Sensed Vegetation Indices and Crop Leaf Area Index? A Global Assessment

Leaf Area Index (LAI) is a key variable that bridges remote sensing observations to the quantification of agroecosystem processes. In this study, we assessed the universality of the relationships between crop LAI and remotely sensed Vegetation Indices (VIs). We first compiled a global dataset of 1459 in situ quality-controlled crop LAI measurements and collected Landsat satellite images to derive five different VIs including Simple Ratio (SR), Normalized Difference Vegetation Index (NDVI), two versions of the Enhanced Vegetation Index (EVI and EVI2), and Green Chlorophyll Index (CI(sub Green)). Based on this dataset, we developed global LAI-VI relationships for each crop type and VI using symbolic regression and Theil-Sen (TS) robust estimator. Results suggest that the global LAI-VI relationships are statistically significant, crop-specific, and mostly non-linear. These relationships explain more than half of the total variance in ground LAI observations (R2 greater than 0.5), and provide LAI estimates with RMSE below 1.2 m2/m2. Among the five VIs, EVI/EVI2 are the most effective, and the crop-specific LAI-EVI and LAI-EVI2 relationships constructed by TS, are robust when tested by three independent validation datasets of varied spatial scales. While the heterogeneity of agricultural landscapes leads to a diverse set of local LAI-VI relationships, the relationships provided here represent global universality on an average basis, allowing the generation of large-scale spatial-explicit LAI maps. This study contributes to the operationalization of large-area crop modeling and, by extension, has relevance to both fundamental and applied agroecosystem research.

Vegetation Index↗

Pinch Experiments in a Table Top Generator

The design and construction of a table top multipurpose capacitor bank of hundred of Joules and hundred of kiloAmperes conceived to be used in small scale Z-pinch experiments is reported. A recent result on a Z-pinch gas embedded discharge using hollow conical electrodes done in a similar table top generator is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Studies of Ions Emission in a Small Plasma Focus Device of Hundreds of Joules

Ion beam emission in plasma focus (PF) discharges was originally investigated to explain the strong forward anisotropy observed in the neutron. Several properties of PF emitted deuteron beams have been measured, including their angular distributions and energy spectra in devices operating with energies from 1 kJ to 1 MJ. At present there is a growing interest in the development of very small PF devices operating under 1 kJ. As part of the characterization program of the very low energy PF devices (<1 kJ) developed at the Chilean Nuclear Energy Commission, the charges particle emission in hydrogen (H{sub 2}) and mixture (H{sub 2}+%Ar) are being studied. In order to obtain an estimation of the ions energy spectrum and ionization grade, by using time of flight method, a graphite collector system operating in the bias ion collector mode was constructed and it is being used. Preliminary results of the ion beams measurements in different experimental conditions, at a plasma focus device of 400 joules (PF-400 J) are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanofocus of tenth of joules and a portable plasma focus of few joules for field applications

A repetitive pinch plasma focus that works with stored energy less than 1 J per shot has be developed at the Chilean Nuclear Energy Commission. The main features of this device, repetitive Nanofocus, are 5 nF of capacity, 5 nH of inductance, 5-10 kV charging voltage, 60-250 mJ stored energy, 5-10 kA current peak, per shot. The device has been operated at 20 Hz in hydrogen and deuterium. X-ray radiographs of materials of different thickness were obtained. Neutrons were detected using a system based upon {sup 3}He proportional counter in chare integrated mode. However, the reproducibility of this miniaturized device is low and several technological subjects have to be previously solved in order to produce neutrons for periods greater than minutes. Further studies in the Nanofocus are being carried out. In addition, a device with a stored energy of a few joules is being explored. A preliminary compact, low weight (3 kg), portable PF device (25 cmx5 cmx5 cm) for field applications has been designed. This device was designed to operate with few kilovolts (10 kV or less) with a stored energy of 2 J and a repetition rate of 10 Hz without cooling. A neutron flux of the order of 10{sup 4}-10{sup 5} n/s is expected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scaling, stability, and fusion mechanisms. Studies using plasma focus devices from tens of kilojoules to tenth of joules

Fusion studies using plasma focus devices from tens of kilojoules to less than one joule performed at the Chilean Nuclear Energy Commission are presented. The similarity of the physical behavior and the scaling observed in these machines are emphasized. Experiments on actual devices show that scaling holds at least through six order of magnitude. In particular all of these devices, from the largest to the smallest, keep the same quantity of energy per particle. Therefore, fusion reactions are possible to be obtained in ultraminiature devices (driven by generators of 0.1 J), as they are in the bigger devices (driven by generators of 1 MJ). However, the stability of the plasma depends on the size and energy of the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics and Density Measurements in a Small Plasma Focus of Tens Joules

As a part of the systematic research conducted to study the scaling of Plasma Focus experiments to small devices, radial dynamic and density measurements using Hydrogen and Deuterium as filling gas in the PF-50 J device are presented. Results confirm that the expected dynamics observed in large experiments and densities of the order 10{sup 25} m{sup -3} at the pinch time are present in our experiments operated at only 67 J.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in Z-pinch research driven by the mega-ampere device SPEED2

Several pinch configurations have being studied at the Chilean Nuclear Energy Commission using the SPEED2 generator: plasma focus, gas embedded z-pinch and wire arrays. SPEED2 is a generator based on Marx technology (4.1 {mu}F equivalent Marx generator capacity, 300 kV, 4 MA in short circuit, 187 kJ, 400 ns rise time, dI/dt{approx}10{sup 13} A/s). Currently the device is being operated at 70kJ stored energy producing a peak current of 2.4 MA in short circuit. In this work results related to studies in gas embedded z-pinch in deuterium and studies in wire arrays are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repetitive Nanofocus: Evidence of neutron and x-ray emission from an ultra miniature pinch plasma focus discharge operating at tens of Hz

Evidence of x-ray and neutron emission from an ultraminiature pinch plasma focus is presented. The stored energy in the device is less than 1J per shot and can be operated at tens of Hz of repetition rate. The main features of this device, repetitive Nanofocus, are 5nF of capacity, 5nH of inductance, 5-10 kV charging voltage, 60-250 mJ stored energy, 5-10 kA current peak, per shot. The device has been operated at 20 Hz in hydrogen and deuterium. X-ray radiographs of materials of different thickness were obtained. Neutrons were detected using a system based upon {sup 3}He proportional counter in current mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗