Transformation mechanisms for the pressure-induced phase transition in single crystal CdS.
Abstract not provided.
Engineering topics
Publications and source records attributed to Morgan, D. V..
Abstract not provided.
Abstract not provided.
X-ray diffraction measurements to characterize phase transitions of dynamically compressed, high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet (ZBL) long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.
Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. Additionally, the system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10 7 molybdenum Kα photons.
A single-pulse x-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line and bremsstrahlung x-ray emission in a 40-ns pulse. A selected anode of either silver or molybdenum produces characteristic K lines used for diffraction. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2-mm by 5-mm spot and 1° full-width-half-maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock-loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.