Search NASA⌕ Search

Engineering topics

Morgan, Kelsey M.

Publications and source records attributed to Morgan, Kelsey M..

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Valence-to-core X-ray emission spectroscopy of titanium compounds using energy dispersive detectors

X-ray emission spectroscopy (XES) of transition metal compounds is a powerful tool for investigating the spin and oxidation state of the metal centers. Valence-to-core (vtc) XES is of special interest, as it contains information on the ligand nature, hybridization, and protonation. To date, most vtc-XES studies have been performed with high-brightness sources, such as synchrotrons, due to the weak fluorescence lines from vtc transitions. Here, we present a systematic study of the vtc-XES for different titanium compounds in a laboratory setting using an X-ray tube source and energy dispersive microcalorimeter sensors. With a full-width at half-maximum energy resolution of approximately 4 eV at the Ti Kβ lines, we measure the XES features of different titanium compounds and compare our results for the vtc line shapes and energies to previously published and newly acquired synchrotron data as well as to new theoretical calculations. Finally, we report simulations of the feasibility of performing time-resolved vtc-XES studies with a laser-based plasma source in a laboratory setting. Our results show that microcalorimeter sensors can already perform high-quality measurements of vtc-XES features in a laboratory setting under static conditions and that dynamic measurements will be possible in the future after reasonable technological developments.

36 MATERIALS SCIENCE↗

Resonant Soft X-Ray Scattering from Stripe-Ordered La 2 - x Ba x Cu O 4 Detected by a Transition-Edge Sensor Array Detector

Resonant soft x-ray scattering (RSXS) is a leading probe of valence-band order in materials best known for detecting charge-density-wave order in copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background, which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition-edge-sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La 2 - x Ba x Cu O 4 at the Cu L 3 / 2 edge (932.2 eV) using a TES detector with 1.5-eV resolution, to evaluate its utility for mitigating the fluorescence-background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a five to ten times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES introduces a promising method to reducing background in RSXS studies and may lead to discoveries in materials exhibiting valence-band order that is fluctuating or glassy.

36 MATERIALS SCIENCE↗

Microwave SQUID Multiplexing for the Lynx X-Ray Microcalorimeter

The Lynx x-ray microcalorimeter (LXM) is an imaging spectrometer for the Lynx satellite mission, an x-ray telescope being considered by NASA to be a new flagship mission. Lynx will enable unique astrophysical observations into the x-ray universe due to its high angular resolution and large field of view. The LXM consists of an array of over 100,000 pixels and poses a significant technological challenge to achieve the high degree of multiplexing required to read out these sensors. We discuss the details of microwave superconducting quantum interference device (SQUID) multiplexing and describe why it is ideally suited to the needs of the LXM. This case is made by summarizing the current and predicted performance of microwave SQUID multiplexing and describing the steps needed to optimize designs for all the LXM arrays. Finally, we describe our plan to advance the technology readiness level (TRL) of microwave SQUID multiplexing of the LXM microcalorimeters to TRL-5 by 2024.

Bennett, Douglas A.↗

Mapping of the Resistance of a Superconducting Transition Edge Sensor as a Function of Temperature, Current, and Applied Magnetic Field

We have measured the resistance R (T, I, B(sub ext) of a superconducting transition edge sensor over the entire transition region on a fine scale, producing a four-dimensional map of the resistance surface. The dimensionless temperature and current sensitivities (alpha equivalence partial derivative log R/partial derivative log T|(sub I) and beta equivalence partial derivative log R/partial derivative log I|(sub T) of the TES resistance have been determined at each point. alpha and beta are closely related to the sensor performance, but show a great deal of complex, large amplitude fine structure over large portions of the surface that is sensitive to the applied magnetic field. We discuss the relation of this structure to the presence of Josephson weak link fringes.

Zhang, Shou↗

Development of X-Ray Microcalorimeter Imaging Spectrometers for the X-Ray Surveyor Mission Concept

Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen inthe 2020 astrophysics decadal survey.1 One of these missions is the X-Ray Surveyor (XRS), and possibleconfigurations of this mission are currently under study by a science and technology definition team (STDT). Oneof the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument arecurrently under discussion. In this paper we review some different detector options that exist for this instrument,and discuss what array formats might be possible. We have developed one design option that utilizes eithertransition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometriesin which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1 pixels. In thispaper we describe the development status of these detectors, and also discuss the different options that exist forreading out the very large number of pixels.

multiplexing↗