Search NASA⌕ Search

Engineering topics

Morris, Christopher

Publications and source records attributed to Morris, Christopher.

67 records · Page 4

Our Next Two Steps for Fukushima Daiichi Muon Tomography

After the vast disasters caused by the great earthquake and tsunami in eastern Japan, we proposed applying our Muon Tomography (MT) technique to help and improve the emergency situation at Fukushima Daiichi using cosmic-ray muons. A reactor-tomography team was formed at LANL which was supported by the Laboratory as a response to a request by the former Japanese Prime Minister, Naoto Kan. Our goal is to help the Japanese people and support remediation of the reactors. At LANL, we have carried out a proof-of-principle technical demonstration and simulation studies that established the feasibility of MT to image a reactor core. This proposal covers the next two critical steps for Fukushima Daiichi Muon Imaging: (1) undertake case study mock-up experiments of Fukushima Daiichi, and (2) system optimization. We requested funding to the US and Japanese government to assess damage of reactors at Fukushima Daiichi. The two steps will bring our project to the 'ready-to-go' level.

47 OTHER INSTRUMENTATION↗

Adjuvant Radiotherapy for Pediatric and Young Adult Nonrhabdomyosarcoma Soft-Tissue Sarcoma

Purpose: To evaluate the prognostic factors, outcomes, and complications in patients aged {<=}30 years with resectable nonrhabdomyosarcoma soft-tissue sarcoma treated at the University of Florida with radiotherapy (RT) during a 34-year period. Methods and Materials: A total of 95 pediatric or young adult patients with nonrhabdomyosarcoma soft-tissue sarcoma were treated with curative intent with surgery and RT at the University of Florida between 1973 and 2007. The most common histologic tumor subtypes were synovial sarcoma in 22 patients, malignant fibrous histiocytoma in 19, and malignant peripheral nerve sheath tumor in 11 patients. The mean age at RT was 22 years (range, 6-30). Of the 95 patients, 73 had high-grade tumors; 45 had undergone preoperative RT and 50 postoperative RT. The prognostic factors for survival, local recurrence, and distant recurrence were analyzed. Results: The median follow-up was 7.2 years (range, 0.4-30.5). The actuarial 5-year local control rate was 88%. A microscopically negative margin was associated with superior local control. Although 83% of local recurrence cases initially developed in the absence of metastases, all patients with local failure ultimately died of their disease. The actuarial estimate of 5-year overall survival and disease-free survival was 65% and 63%, respectively. Of all the deaths, 92% were disease related. An early American Joint Committee on Cancer stage, tumor <8 cm, and the absence of neurovascular invasion were associated with superior disease-free survival. The National Cancer Institute Common Toxicity Criteria, version 3, Grade 3-4 treatment complication rate was 9%. No secondary malignancies were observed. Conclusion: In the present large single-institution study, we found positive margins and locally advanced features to be poor prognostic factors for both local progression and survival. The results from the present study have helped to characterize the therapeutic ratio of RT in pediatric and young adult sarcoma patients and have provided a basis for identifying high-risk patients for whom treatment intensification might be justified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A class of ejecta transport test problems

Hydro code implementations of ejecta dynamics at shocked interfaces presume a source distribution function ofparticulate masses and velocities, f{sub 0}(m, v;t). Some of the properties of this source distribution function have been determined from extensive Taylor and supported wave experiments on shock loaded Sn interfaces of varying surface and subsurface morphology. Such experiments measure the mass moment of f{sub o} under vacuum conditions assuming weak particle-particle interaction and, usually, fully inelastic capture by piezo-electric diagnostic probes. Recently, planar Sn experiments in He, Ar, and Kr gas atmospheres have been carried out to provide transport data both for machined surfaces and for coated surfaces. A hydro code model of ejecta transport usually specifies a criterion for the instantaneous temporal appearance of ejecta with source distribution f{sub 0}(m, v;t{sub 0}). Under the further assumption of separability, f{sub 0}(m,v;t{sub 0}) = f{sub 1}(m)f{sub 2}(v), the motion of particles under the influence of gas dynamic forces is calculated. For the situation of non-interacting particulates, interacting with a gas via drag forces, with the assumption of separability and simplified approximations to the Reynolds number dependence of the drag coefficient, the dynamical equation for the time evolution of the distribution function, f(r,v,m;t), can be resolved as a one-dimensional integral which can be compared to a direct hydro simulation as a test problem. Such solutions can also be used for preliminary analysis of experimental data. We report solutions for several shape dependent drag coefficients and analyze the results of recent planar dsh experiments in Ar and Xe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring momentum for charged particle tomography

Methods, apparatus and systems for detecting charged particles and obtaining tomography of a volume by measuring charged particles including measuring the momentum of a charged particle passing through a charged particle detector. Sets of position sensitive detectors measure scattering of the charged particle. The position sensitive detectors having sufficient mass to cause the charged particle passing through the position sensitive detectors to scatter in the position sensitive detectors. A controller can be adapted and arranged to receive scattering measurements of the charged particle from the charged particle detector, determine at least one trajectory of the charged particle from the measured scattering; and determine at least one momentum measurement of the charged particle from the at least one trajectory. The charged particle can be a cosmic ray-produced charged particle, such as a cosmic ray-produced muon. The position sensitive detectors can be drift cells, such as gas-filled drift tubes.

Morris, Christopher↗

Ejecta model development at pRad (u)

In July 2009 we fielded three explosively (HE) driven Richtmyer-Meshkov instability experiments at the LANSCE Proton Radiography Facility (pRad), and in August of 2009 we fielded one flyer plate experiment on the pRad 40 mm powder gun. One HE experiment was done in vacuum, and the other two within four atmospheres of noble gasses: Xe and Ne. These two gases were chosen to study the viscous effects on ejecta formation. It is unexpected, but the viscosity {eta} of Ne is twice that of Xe, and, due to the atomic mass difference between the two, the kinematic viscosity ({eta}/{rho}) of Ne is about ten times that of Xe. The results showed that ejecta formation is sensitively linked to the gas density, which implies that the Weber number is more important in ejecta formation than the Reynolds number.

99 GENERAL AND MISCELLANEOUS↗

A range muon tomography performance study for the detection of explosives

Soft cosmic ray tomography has been shown to successfully discriminate materials with various density levels due to their ability to deeply penetrate matter, allowing sensitivity to atomic number, radiation length and density. Because the multiple muon scattering signal from high Z-materials is very strong, the technology is well suited to the detection of the illicit transportation of special and radiological nuclear materials. In addition, a recent detection technique based on measuring the lower energy particles that do not traverse the material (range radiography), allows to discriminate low and medium Z-materials. This is shown in [4] using Monte Carlo simulations. More recently, using a mini muon tracker developed at Los Alamos National Laboratory, we performed various experiments to try out the radiation length technology. This paper presents the results from real experiments and evaluates the likelihood that soft cosmic ray tomography may be applied to detect high-explosives.

36 MATERIALS SCIENCE↗

HUGONIOT MEASUREMENTS AT LOW PRESSURES IN TIN USING 800 MeV PROTON RADIOGRAPHY

A 20 mm long 8 mm diameter cylindrical tin target has been shocked to a pressure just below the beta->gamma phase change, using a small, low density PETN charge mounted on the opposite side of a thin stainless steel diaphragm. The density jump and shock velocity were measured radiographically at multiple points as the shock wave moved though the sample and the pressure dropped, using the proton radiography facility at LANL. This provided a quasi-continuous record along the principal Hugoniot from a peak shock velocity of 3.27 km/sec to a minimum of 3.09 km/sec. Edge release effects were removed from the data using simple tomographic reconstruction techniques. The data and analysis are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation portal monitor system and method

A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

47 OTHER INSTRUMENTATION↗

Quasi 1-D Study of Pulse Detonation Rocket Engine Blowdown Gasdynamics and Performance

This viewgraph representation provides an overview of research which develops a quasi one dimensional chemistry computational fluid dynamics code to study the effect of nozzle design on the performance of pulse detonation rocket engines (PDREs). Topics considered include: PDREs vs. steady-state rocket engines (SSREs), PDRE cycles, numerical models of idealized PDRE performance, thrust determination of PDRE, specific geometries, and nozzle design and geometry.

Morris, Christopher↗