A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Multi-GeV Electron Bunches from an All-Optical Laser Wakefield Accelerator

We present the first demonstration of multi-GeV laser wakefield acceleration in a fully optically formed plasma waveguide, with an acceleration gradient as high as 25 GeV/m . The guide was formed via self-waveguiding of < 15 J, 45 fs (< ~ 300 TW) pulses over 20 cm in a low-density hydrogen gas jet, with accelerated electron bunches driven up to 5 GeV in quasimonoenergetic peaks of relative energy width as narrow as ~ 15 % , with divergence down to ~ 1mrad and charge up to tens of picocoulombs. Energy gain is inversely correlated with on-axis waveguide density in the range Ne0 = (1.3 – 3.2) x 10 17 cm –3 . We find that shot-to-shot stability of bunch spectra and charge are strongly dependent on the pointing of the injected laser pulse and gas jet uniformity. We also observe evidence of pump depletion-induced dephasing, a consequence of the long optical guiding distance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

External and Turbomachinery Flow Control Working Group

Broad Flow Control Issues: a) Understanding flow physics. b) Specific control objective(s). c) Actuation. d) Sensors. e) Integrated active flow control system. f) Development of design tools (CFD, reduced order models, controller design, understanding and utilizing instabilities and other mechanisms, e.g., streamwise vorticity).

Ahmadi, G.↗

Driving on the surface of Mars with the rover sequencing and visualization program

Operating a rover on Mars is not possible using teleoperations due to the distance involved and the bandwith limitations. To operate these rovers requires sophisticated tools to make operators knowledgeable of the terrain, hazards, features of interest, and rover state and limitations, and to support building command sequences and rehearsing expected operations. This paper discusses how the Rover Sequencing and Visualization program and a small set of associated tools support this requirement.

autonomy↗

Terrain Modelling for Immersive Visualization for the Mars Exploration Rovers

Immersive environments are being used to support mission operations at the Jet Propulsion Laboratory. This technology contributed to the Mars Pathfinder Mission in planning sorties for the Sojourner rover and is being used for the Mars Exploration Rover (MER) missions. The stereo imagery captured by the rovers is used to create 3D terrain models, which can be viewed from any angle, to provide a powerful and information rich immersive visualization experience. These technologies contributed heavily to both the mission success and the phenomenal level of public outreach achieved by Mars Pathfinder and MER. This paper will review the utilization of terrain modelling for immersive environments in support of MER.

immersive environments↗

The Athena SDM rover: A testbed for Mars rover mobility

In this paper we describe the software aspects of the overall Athena SDM rover mobility system in three parts: the control electronics, the software architecture and development environment, and surface navigation software. The Athena SDM architecture has been shown to be capable of meeting mission navigation requirements by being able to safely drive 100 meters using allowable resources within three hours.

design↗

Post-metamorphic fluid infiltration into granulites from the Adirondack Mountains, USA

Post-metamorphic effects in the anorthosites of the Adirondacks, New York were described. Calcite-chlorite-sericite assemblages occur as veins, in disseminated form and as clots, and document retrograde fluid infiltration. These features are associated with late-state CO2-rich fluid inclusions. Stable isotope analyses of calcites indicates that the retrograde fluids interacted with meta-igneous and supracrustal lithologies, but the precise timing of the retrogression is as yet unknown.

Morrison, J.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.