Search NASA⌕ Search

Engineering topics

Morrison, William H

Publications and source records attributed to Morrison, William H.

Method of estimating pulse response using an impedance spectrum

Electrochemical Impedance Spectrum data are used to predict pulse performance of an energy storage device. The impedance spectrum may be obtained in-situ. A simulation waveform includes a pulse wave with a period greater than or equal to the lowest frequency used in the impedance measurement. Fourier series coefficients of the pulse train can be obtained. The number of harmonic constituents in the Fourier series are selected so as to appropriately resolve the response, but the maximum frequency should be less than or equal to the highest frequency used in the impedance measurement. Using a current pulse as an example, the Fourier coefficients of the pulse are multiplied by the impedance spectrum at corresponding frequencies to obtain Fourier coefficients of the voltage response to the desired pulse. The Fourier coefficients of the response are then summed and reassembled to obtain the overall time domain estimate of the voltage using the Fourier series analysis.

25 ENERGY STORAGE↗

Crosstalk compensation in analysis of energy storage devices

Estimating impedance of energy storage devices includes generating input signals at various frequencies with a frequency step factor therebetween. An excitation time record (ETR) is generated to include a summation of the input signals and a deviation matrix of coefficients is generated relative to the excitation time record to determine crosstalk between the input signals. An energy storage device is stimulated with the ETR and simultaneously a response time record (RTR) is captured that is indicative of a response of the energy storage device to the ETR. The deviation matrix is applied to the RTR to determine an in-phase component and a quadrature component of an impedance of the energy storage device at each of the different frequencies with the crosstalk between the input signals substantially removed. This approach enables rapid impedance spectra measurements that can be completed within one period of the lowest frequency or less.

25 ENERGY STORAGE↗

AN ADVANCED CALIBRATION PROCEDURE FOR COMPLEX IMPEDANCE SPECTRUM MEASUREMENTS OF ADVANCED ENERGY STORAGE DEVICES

With the increasing demand for electric and hybrid electric vehicles and the explosion in popularity of mobile and portable electronic devices such as laptops, cell phones, e-readers, tablet computers and the like, reliance on portable energy storage devices such as batteries has likewise increased. The concern for the availability of critical systems in turn drives the availability of battery systems and thus the need for accurate battery health monitoring has become paramount. Over the past decade the Idaho National Laboratory (INL), Montana Tech of the University of Montana (Tech), and Qualtech Systems, Inc. (QSI) have been developing the Smart Battery Status Monitor (SBSM), an integrated battery management system designed to monitor battery health, performance and degradation and use this knowledge for effective battery management and increased battery life. Key to the success of the SBSM is an in-situ impedance measurement system called the Impedance Measurement Box (IMB). One of the challenges encountered has been development of an accurate, simple, robust calibration process. This paper discusses the successful realization of this process.

25 ENERGY STORAGE↗

Unilateral Radiotherapy for the Treatment of Tonsil Cancer

Purpose: To assess, through a retrospective review, clinical outcomes of patients with squamous cell carcinoma of the tonsil treated at the M. D. Anderson Cancer Center with unilateral radiotherapy techniques that irradiate the involved tonsil region and ipsilateral neck only. Methods and Materials: Of 901 patients with newly diagnosed squamous cell carcinoma of the tonsil treated with radiotherapy at our institution, we identified 102 that were treated using unilateral radiotherapy techniques. All patients had their primary site of disease restricted to the tonsillar fossa or anterior pillar, with <1 cm involvement of the soft palate. Patients had TX (n = 17 patients), T1 (n = 52), or T2 (n = 33) disease, with Nx (n = 3), N0 (n = 33), N1 (n = 23), N2a (n = 21), or N2b (n = 22) neck disease. Results: Sixty-one patients (60%) underwent diagnostic tonsillectomy before radiotherapy. Twenty-seven patients (26%) underwent excision of a cervical lymph node or neck dissection before radiotherapy. Median follow-up for surviving patients was 38 months. Locoregional control at the primary site and ipsilateral neck was 100%. Two patients experienced contralateral nodal recurrence (2%). The 5-year overall survival and disease-free survival rates were 95% and 96%, respectively. The 5-year freedom from contralateral nodal recurrence rate was 96%. Nine patients required feeding tubes during therapy. Of the 2 patients with contralateral recurrence, 1 experienced an isolated neck recurrence and was salvaged with contralateral neck dissection only and remains alive and free of disease. The other patient presented with a contralateral base of tongue tumor and involved cervical lymph node, which may have represented a second primary tumor, and died of disease. Conclusions: Unilateral radiotherapy for patients with TX-T2, N0-N2b primary tonsil carcinoma results in high rates of disease control, with low rates of contralateral nodal failure and a low incidence of acute toxicity requiring gastrostomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

25 ENERGY STORAGE↗

Rapid Impedance Spectrum Measurements for State-of-Health Assessment of Energy Storage Devices

Harmonic compensated synchronous detection (HCSD) is a technique that can be used to measure wideband impedance spectra within seconds based on an input sum-of-sines signal having a frequency spread separated by harmonics. The battery (or other energy storage device) is excited with a sum-of-sines current signal that has a duration of at least one period of the lowest frequency. The voltage response is then captured and synchronously detected at each frequency of interest to determine the impedance spectra. This technique was successfully simulated using a simplified battery model and then verified with commercially available Sanyo lithium-ion cells. Simulations revealed the presence of a start-up transient effect when only one period of the lowest frequency is included in the excitation signal. This transient effect appears to only influence the low-frequency impedance measurements and can be reduced when a longer input signal is used. Furthermore, lithium-ion cell testing has indicated that the transient effect does not seem to impact the charge transfer resistance in the mid-frequency region. The degradation rates for the charge transfer resistance measured from the HCSD technique were very similar to the changes observed from standardized impedance spectroscopy methods. Results from these studies, therefore, indicate that HCSD is a viable, rapid alternative approach to acquiring impedance spectra.

25 ENERGY STORAGE↗

Prediction of Neck Dissection Requirement After Definitive Radiotherapy for Head-and-Neck Squamous Cell Carcinoma

Background: This analysis was undertaken to assess the need for planned neck dissection in patients with a complete response (CR) of involved nodes after irradiation and to determine the benefit of a neck dissection in those with less than CR by tumor site. Methods: Our cohort included 880 patients with T1-4, N1-3M0 squamous cell carcinoma of the oropharynx, larynx, or hypopharynx who received treatment between 1994 and 2004. Survival curves were calculated by the Kaplan-Meier Method, comparisons of rates with the log-rank test and prognostic factors by Cox's proportional hazard model. Results: Nodal CR occurred in 377 (43%) patients, of whom 365 patients did not undergo nodal dissection. The 5-year actuarial regional control rate of patients with CR was 92%. Two hundred sixty-eight of the remaining patients (53%) underwent neck dissections. The 5-year actuarial regional control rate for patients without a CR was 84%. Those who had a neck dissection fared better with 5-year actuarial regional control rates of 90% and 76% for those operated and those not operated (p < 0.001). Variables associated with poorer regional control rates included higher T and N stage, non-oropharynx cancers, non-CR, both clinical and pathological. Conclusions: With 92% 5-year neck control rate without neck dissection after CR, there is little justification for systematic neck dissection. The addition of a neck dissection resulted in higher neck control after partial response though patients with viable tumor on pathology specimens had poorer outcomes. The identification of that subgroup that benefits from additional treatment remains a challenge.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crosstalk Compensation for a Rapid, Higher Resolution Impedance Spectrum Measurement

Batteries and other energy storage devices are playing larger roles in various industries (e.g., military, automotive, electric utilities, etc.) as the U.S. seeks to reduce its dependence on foreign energy resources. As such, there exists a significant need for accurate, robust state-of-health assessment techniques. Present techniques tend to focus on simple, passive monitoring of voltage and current at a given ambient temperature. However, this approach has the disadvantage of ignoring key elements of health, that is, changes in resistance growth and power fade. Impedance spectroscopy is considered a useful laboratory tool in gauging changes in the resistance and power performance, but it has not been widely considered as an onboard diagnostic tool due to the length of time required to complete the measurement. Cross-Talk Compensation (CTC) is a novel approach that enables rapid, high resolution impedance spectra measurements using a hardware platform that could be designed as an embedded system. This input signal consists of a sum-of-sines excitation current that has a known frequency spread and a duration of one period of the lowest frequency. The voltage response is then captured at a sufficiently fast sample rate. Previously developed rapid impedance spectrum measurement techniques either required a longer excitation signal or a sum-of-sines signal that was separated by harmonic frequencies to reduce or eliminate, respectively, the cross-talk interference in the calculated results. The distinct advantage of CTC, however, is that non-harmonic frequencies can now be included within the excitation signal while still keeping the signal duration at one period of the lowest frequency. Since the frequency spread of the input signal is known, the crosstalk interference between sinusoidal signals within the sum-of-sines at a given frequency of interest can be pre-determined and assigned to an error matrix. Consequently, the real and imaginary components of the impedance at each frequency of interest can be calculated using simple linear algebra based on the error matrix and measured response from the energy storage device given the excitation signal. Analytical validation of CTC over a frequency range between 2000 and 0.1 Hz (i.e., a ten-second input signal duration) was performed using a standardized battery lumped parameter model. The results indicated that the CTC was able to successfully resolve more than 45 frequencies within a sum-of-sines excitation signal, whereas previous techniques could only resolve up to 15 frequencies. A simplified derivation of the CTC technique and its corresponding analytical validation studies using the lumped-parameter model will be presented.

25 ENERGY STORAGE↗