Search NASASearch

Engineering topics

Morrow, G. W.

Publications and source records attributed to Morrow, G. W..

Qualification Testing of General Electric 50 Ah Nickel-Cadmium Cells with New Separator and New Positive Plate Processing

Forty-two 50 Ah aerospace nickel-cadmium cells were delivered to Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985, for the purpose of evaluating and qualifying a new nylon separator material Pellon 2536, and the new GE Positive Plate Nickel Attack Control Passivation process. Testing began in May, 1985, at the Naval Weapons Support Center (NWSC) in Crane, Indiana with standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985, with approximately 1200 LEO cycles complete at this writting. Early test results show that cells with positive plate passivation exhibit higher than normal charge voltage characteristics. Other aspects of performance were nominal.

Morrow, G. W.

NOAA 26.5 Ah LEO characterization test

The General Electric (GE) 26.5 Ah NOAA-G flight nickel-cadmium cells were obtained from RCA-Astro Electronics to undergo performance characterization testing at the Goddard Space Flight Center (GSFC). This lot of cells was manufactured with passivated positive plate, to control nickel structure attack duing active material impregnation, and less electrolyte than normal (less than 3cc/Ah). The cells were tested in a parametric low Earth orbit (LEO) cycling regime that was previously used to test and characterize standard 50 Ah cells. Life cycle testing at the Naval Weapons Support Center (NWSC), in Crane, followed. The results of the test showed nominal performance in comparison with previous test data on the standard 50. Life cycle testing in the NOAA orbital regime is continuing at NWSC.

Morrow, G. W.

The 1984 Goddard Space Flight Center Battery Workshop

Various topics related to spacecraft power supply systems are discussed. Regenerative fuel cells, lithium molybdenum batteries, nickel hydrogen batteries, nickel cadmium batteries, failure analysis, and performance testing are covered.

Morrow, G. W.

Nickel Cadmium Cell Design Variable Program Data Analysis

A program was undertaken to evaluate eight of the more important nickel-cadmium cell designs that are currently being used or that have been used during the past 15 years. Design variables tested in this program included teflonated negative plates, silver treated negative plates, light plate loading level, no positive plate cadmium treatment, plate design of 1968, utilizing both old and new processing techniques, and electrochemically impregnated positive plates. The data acquired from these test packs in a low Earth orbit cycling regime is presented and analyzed here. This data showed conclusively that the cells manufactured with no positive plate cadmium treatment outperformed all other cell designs in all aspects of the program and that the cells with teflonated negative electrodes performed very poorly.

Morrow, G. W.

Nickel-Cadmium Cell Design Variable Program Data Analysis

A program was undertaken in conjunction with the General Electric Company to evaluate 9 of the more important nickel cadmium aerospace cell designs that are currently being used or that have been used in the past 15 years. Design variables tested in this program included teflonated negative plates, silver treated negative plates, light plate loading level, no positive plate cadmium treatment, plate design of 1968 utilizing both old and new processing techniques, and electrochemically impregnated positive plates. The data acquired from these test packs in a low Earth orbit cycling regime is presented and analyzed here. This data showed conclusively that the cells manufactured with no positive plate cadmium treatment outperformed all other cell designs in all aspects of the program and that the cells with teflonated negative electrodes performed very poorly.

Morrow, G. W.

Comparison of Standard and Heart-pacer Type 3rd Electrodes in Design Variable Cells

Nine packs of sealed aerospace nickel cadmium cells were put on life test in February 1979. Each 5 cell pack contained one cell with a standard sensor signal electrode and one cell with a new heart pacer sensor signal electrode. Testing was discontinued in May 1983 and the signal electrode performance data was studied. It was found that the heart pacer electrode generally provided a greater voltage swing over a cycle; that both types of electrodes lost significant sensitivity during life, and that both types of electrodes show great signal variation from cell to cell.

Morrow, G. W.