Optimum full-scale subsonic wind tunnel

The needs and reasons for performing full-scale subsonic research have been studied. Full-scale wind-tunnel requirements are described; recommended size, airspeed, acoustic capabilities, and flow quality are developed; and data-acquisition systems, productivity, automation, and some cost elements are discussed. It is proposed that the optimum full-scale, subsonic wind tunnel be large enough to accommodate aerodynamic and acoustic investigations on most advanced aircraft, which exhibit complex engine/lifting-surface flow-field interactions, including advanced rotorcraft.

Mort, K. W.

Aeroacoutic characteristics of a large, variable-pitch, variable-speed fan system

The acoustic and aerodynamic performance of the new drive fans for the NASA Ames 40- by 80-/80- by 120-foot wind tunnel was investigated. Results show that a fan system with variable-speed and variable-pitch rotor blades allows the operator to control noise and energy consumption, at a given mass flow rate, through the choice of blade speed and pitch. A low speed and high blade pitch will generally create the least noise at the least energy cost. An empirical method is described which predicts the sound power of this fan system reasonably well.

Soderman, P. T.

The aerodynamic performance of several flow control devices for internal flow systems

An experimental reseach and development program was undertaken to develop and document new flow-control devices for use in the major modifications to the 40 by 80 Foot wind tunnel at Ames Research Center. These devices, which are applicable to other facilities as well, included grid-type and quasi-two-dimensional flow straighteners, louver panels for valving, and turning-vane cascades with net turning angles from 0 deg to 90 deg. The tests were conducted at model scale over a Reynolds number range from 2 x 100,000 to 17 x 100,000, based on chord. The results showed quantitatively the performance benefits of faired, low-blockage, smooth-surface straightener systems, and the advantages of curved turning-vanes with hinge-line gaps sealed and a preferred chord-to-gap ratio between 2.5 and 3.0 for 45 deg or 90 deg turns.

Eckert, W. T.

Status and capabilities of the National Full Scale Facility 40- by 80-foot wind tunnel modification

The background, requirements, and aerodynamic design of the modified NASA Ames 40 x 80 ft wind tunnel are reviewed, along with the systems integration and systems test results. Advancing vehicle sizes and airspeeds required a larger wind tunnel test section and a capability for 100 and 300 knots airspeed simulation. Acoustic mufflers at the inlet and exit of the nonreturn circuit provide noise suppression. The enlarged test section is intended to accomodate the complex flowfields of wings with high lift coefficients, and the drive system is designed with minimum residual swirl. Features of the fan blades are examined, along with characteristics of the test channels, control vanes and louvers, the exit, circuit losses, temperature rises during operation of the nonreturn circuit, and the facility acoustics. Specific construction problems and solutions for the conversion process are outlined, and it is noted that operational status is expected at the end of 1982.

Mort, K. W.

An experimental investigation of two large annular diffusers with swirling and distorted inflow

Two annular diffusers downstream of a nacelle-mounted fan were tested for aerodynamic performance, measured in terms of two static pressure recovery parameters (one near the diffuser exit plane and one about three diameters downstream in the settling duct) in the presence of several inflow conditions. The two diffusers each had an inlet diameter of 1.84 m, an area ratio of 2.3, and an equivalent cone angle of 11.5, but were distinguished by centerbodies of different lengths. The dependence of diffuser performance on various combinations of swirling, radially distorted, and/or azimuthally distorted inflow was examined. Swirling flow and distortions in the axial velocity profile in the annulus upstream of the diffuser inlet were caused by the intrinsic flow patterns downstream of a fan in a duct and by artificial intensification of the distortions. Azimuthal distortions or defects were generated by the addition of four artificial devices (screens and fences). Pressure recovery data indicated beneficial effects of both radial distortion (for a limited range of distortion levels) and inflow swirl. Small amounts of azimuthal distortion created by the artificial devices produced only small effects on diffuser performance. A large artificial distortion device was required to produce enough azimuthal flow distortion to significantly degrade the diffuser static pressure recovery.

Eckert, W. T.

Earth winds, flow quality, and the minimum-protection inlet treatment for the NASA Ames 80- by 120-foot wind tunnel nonreturn circuit

The effect of the external wind on the quality of the flow in the test section was studied. The flow quality achievable with the complex treatment as well as that with the planned minimum treatment system is discussed. A scale model coupled with on site wind measurements demonstrated that the minimum treatment selected can provide adequate testing capabilities in the presence of the prevailing local winds, and that test programs will not be significantly affected by adverse wind effects on the test section flow quality.

Eckert, W. T.

Subsonic wind-tunnel performance

Analysis of conditional sampling averages for turbulent flows shows how conditional averages can be related to conventional averages incorporated into existing flow models. Technique allows vast quantities of data generated by conditional sampling to be analyzed in coherent way.

Eckert, W. T.

An aerodynamic investigation of two 1.83-meter-diameter fan systems designed to drive a subsonic wind tunnel

An experimental, aerodynamic investigation was made of two 1.83 m diameter fan systems which are being considered for the repowered drive section of the 40- by 80-foot wind tunnel at NASA Ames Research Center. One system was low speed, the other was high speed. The low speed fan was tested at various stagger angles from 32.9 deg to 62.9 deg. At a fan blade stagger angle of 40.8 deg and operating at a tip speed of 1155 m/sec, the low speed fan developed 207.3 m of head. The high speed fan had a design blade stagger angle of 56.2 deg and was tested at this stagger angle only. The high speed fan operating at 191.5 m/sec developed 207.3 m of head. Radial distributions of static pressure coefficients, total pressure coefficients, and angles of swirl are presented. Radial surveys were conducted at four azimuth locations in front of the fan, and repeated downstream of the fan. Data were taken for various flow control devices and for two inlet contraction lengths.

Page, V. R.

Improving large-scale testing capability by modifying the 40- by 80-foot wind tunnel

Interagency studies conducted during the last several years have indicated the need to improve full-scale testing capabilities. The studies showed that the most effective trade between test capability and facility cost was provided by repowering the existing Ames Research Center 40- by 80-foot wind tunnel to increase the maximum speed from about 100 m/s (200 knots) to about 150 m/s (300 knots) and by adding a new 24- by 37-m (80- by 120-ft) test section powered for about a 50-m/s (100-knot) maximum speed. This paper reviews the design of the facility, a few of its test capabilities, and some of its unique features.

Mort, K. W.

Aerodynamic design guidelines and computer program for estimation of subsonic wind tunnel performance

General guidelines are given for the design of diffusers, contractions, corners, and the inlets and exits of non-return tunnels. A system of equations, reflecting the current technology, has been compiled and assembled into a computer program (a user's manual for this program is included) for determining the total pressure losses. The formulation presented is applicable to compressible flow through most closed- or open-throat, single-, double-, or non-return wind tunnels. A comparison of estimated performance with that actually achieved by several existing facilities produced generally good agreement.

Eckert, W. T.

An experimental investigation of end treatments for nonreturn wind tunnels

The results of a series of flow quality and performance tests on several inlet and exit configurations for nonreturn wind tunnels are presented. Test section flow angularities, local dynamic pressure variations, and total-pressure-loss variations are presented as functions of wind-to-test-section dynamic pressure ratio. The results show that a nonreturn wind tunnel should have end treatments with three characteristics: (1) a vertical exit system, (2) a horizontal inlet system, and (3) an area of protected enclosure at the inlet. Inlet and exhaust treatments were developed that produced good aerodynamic flow qualities with low power penalties.

Eckert, W. T.

The rationale and design features for the 40 by 80/80 by 120 foot wind tunnel

A substantial increase in the test capability of full scale wind tunnels is considered. In order to determine the most cost effective means for providing this desired increase in test capability, a series of design studies were conducted of various new facilities as well as of major modifications to the existing 40- by 80-foot wind tunnel. The most effective trade between test capability and facility cost was provided by repowering the existing 40 by 80 foot wind tunnel to increase the maximum speed from 200 knots to 300 knots and by the addition of a new 80- by 120-foot test section having a 110 knot maximum speed. The design of the facility is described with special emphasis on the unique features, such as the drive system which absorbs nearly four times the power without an increase in noise, and the large flow diversion devices required to interface the two test sections to a single drive.

Mort, K. W.

Wind sensitivity studies of a non-return wind tunnel with a 216- by 432-mm (8.5- by 17.0-inches) test section, phase 2

The refinement of inlet and exit treatments were studied which would minimize the effect of external wind on the test-section flow quality of a nonreturn wind tunnel. The investigation was conducted in the Ames Research Center 40- by 80-foot Wind Tunnel which served as the wind source. Several inlets and two exits were tested at wind directions ranging from 0 to 180 degrees and at wind-to-test-section velocity ratios from zero to somewhat greater than one. For the best inlet configuration the flow quality was good, with a velocity deviation in each of the three component directions generally less. The loss in total pressure due to the inlet treatment was low: about 0.035 of the test-section dynamic pressure for the no-wind case.

Eckert, W. T.

The steady-state flow quality of an open return wind tunnel model.

The structural cost of open return wind tunnels is significantly less than that of the more conventional closed return wind tunnels. However, because of the effects of external winds, the flow quality of open return wind tunnels is an area of concern at the low speeds required for V/STOL testing. The development of a configuration which has good flow quality at low as well as at high test speeds is described. The flow quality required at the low test speeds of interest for V/STOL aircraft is discussed and alternatives to the traditional manner of specifying the flow quality requirements in terms of dynamic pressure and angle of attack are suggested.

Mort, K. W.

Wind sensitivity studies of a non-return wind tunnel, with a 216- by 432-mm (8.5- by 17.0-inch) test section, phase 1

The study to develop inlet and exit treatments which would minimize the effect of external wind on the test-section flow quality of a nonreturn wind tunnel is reported. The investigation was conducted in the Ames Research Center 40- by 80-Foot Wind Tunnel which served as the wind source. Several inlets and two exits were tested at wind directions ranging from 0 to 180 degrees and at wind-to-test-section velocity ratios between zero and one. For the best inlet configuration the flow quality was good, with a velocity deviation in each of the three directions generally less than 1/2 knot (0.26 m/sec) for wind velocities of 15 knots (7.7 m/sec) or less. The loss in total pressure due to the inlet treatment was low: about 0.03 of the test-section dynamic pressure.

Eckert, W. T.

Full scale subsonic wind tunnel requirements and design studies

The justification and requirements are summarized for a large subsonic wind tunnel capable of testing full-scale aircraft, rotor systems, and advanced V/STOL aircraft propulsion systems. The design considerations and constraints for such a facility are reviewed, and the trades between facility test capability and costs are discussed. The design studies showed that the structural cost of this facility is the most important cost factor. For this reason (and other considerations such as requirements for engine exhaust gas purging) an open-return wind tunnel having two test sections was selected. The major technical problem in the design of an open-return wind tunnel is maintaining good test section flow quality in the presence of external winds. This problem has been studied extensively, and inlet and exhaust systems which provide satisfactory attenuation of the effects of external winds on test section flow quality were developed.

Kelly, M. W.

The steady-state flow quality in a model of a non-return wind tunnel

The structural cost of non-return wind tunnels is significantly less than that of the more conventional closed-circuit wind tunnels. However, because of the effects of external winds, the flow quality of non-return wind tunnels is an area of concern at the low test speeds required for V/STOL testing. The flow quality required at these low speeds is discussed and alternatives to the traditional manner of specifying the flow quality requirements in terms of dynamic pressure and angularity are suggested. The development of a non-return wind tunnel configuration which has good flow quality at low as well as at high test speeds is described.

Mort, K. W.